PT 1000 SENSOR CONNECTION Search Results
PT 1000 SENSOR CONNECTION Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| SF-NLMAMB0001-0001 | Amphenol Cables on Demand | Amphenol SF-NLMAMB0001-0001 OSFP 400G Loopback Adapter Module for OSFP Port Testing - 0dB Attenuation & 0W Power Consumption [400-Gigabit Ethernet Ready] | |||
| SF-NLNAMB0001-0001 | Amphenol Cables on Demand | Amphenol SF-NLNAMB0001-0001 QSFP-DD 400G Loopback Adapter Module for QSFP-DD Port Testing - 0dB Attenuation & 0W Power Consumption [400-Gigabit Ethernet Ready] | |||
| ST1000GXH35 | Toshiba Electronic Devices & Storage Corporation | IEGT, 4500 V, 1000 A, 2-120B1S | Datasheet | ||
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet |
Documents mentioning PT 1000 SENSOR CONNECTION
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ricos ricos Distributed I/O Modules PT/TC Modules | ricos ricos Distributed I/O Modules PT/TC Modules 4 sensor inputs per module, self-setting to PT100/PT1000 sensors for 2-wire, 3-wire and 4-wire connection for thermocouples type J/K Dimensions (mm): W x H x D 69 x 92 x 51 Description Analog module 4 inputs PT 100/1000 |
Original | ||||
| Transmitter with Built-in Temperature Sensor Type | Transmitter with Built-in Temperature Sensor Type G 8911 1010 Du line ® Fieldbus Installationbus • AnaLink temperature transmitter with built-in Pt 1000 sensor • Temperature range: -30°C to +60°C (-22° to +140°F) • Uses only 1 channel • Channel coding by GAP 1605 |
Original | ||||
| pt 1000 sensor | Transmitter with Built-in Temperature Sensor Type G 8911 1010 Du line ® Fieldbus Installationbus • AnaLink temperature transmitter with built-in Pt 1000 sensor • Temperature range: -30°C to +60°C (-22° to +140°F) • Uses only 1 channel • Channel coding by GAP 1605 |
Original | ||||
| pt 1000 sensor | Du line Temperature Sensor Type G 8611 1010 ® Fieldbus Installationbus • AnaLink temperature transmitter with built-in Pt 1000 sensor • Temperature range: -30°C to +60°C (-22° to +140°F) • Uses only 1 channel • Channel coding by GAP 1605 • Easily mountable |
Original | ||||
| 5080c | IB ST (ZF) 24 PT 100 4/4 Analog Input Module with 4 Channels for the Connection of Resistance Temperature Detectors (RTDs) 5080C000 Data Sheet 5080C 01/2000 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 F E |
Original | ||||
| IB IL TEMP 2 RTD INTERBUS Inline Terminal With | IB IL TEMP 2 RTD INTERBUS Inline Terminal With Two Analog Input Channels for the Connection of Temperature Shunts (RTD) Data Sheet 5755B 02/2001 5 7 5 5 1 0 0 1 This data sheet is intended to be used in conjunction with the "Configuring and Installing the INTERBUS Inline |
Original | ||||
| MCR-FL-HT-TS-I-EX Programmable Intrinsically Safe | MCR-FL-HT-TS-I-EX Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer for Connection Head With HART Protocol INTERFACE Data Sheet Temperature 1 © PHOENIX CONTACT - 08/2006 Description Customer-specific measuring range settings, linearization, |
Original | ||||
| sensor | Remote I/O Pt/TC modules ricos • 4 sensor inputs per module self-setting on Pt100 / Pt1000 sensors • For thermocouples type J / K / T • For 2, 3 and 4 wire connection • Electronics can be replaced without disconnection of the wiring Dimensions (mm): W x H x D |
Original | ||||
| 650t | Specification sheet ■■ 650T Series Transmitter Model 652 Temperature transmitter and sensor Totally flexible, easily specified – meets your needs with a standard product ■■ Choice of connection heads, styles and materials – designed for flexibility |
Original | ||||
| Platinum Temperature Sensors 22/23 CustomSens | Platinum Temperature Sensors 22/23 CustomSens Thin-film temperature sensors with universal connection possibilities It is the policy of IST to put forward as many sensor options as possible to best serve the customers’ needs. True to this policy is the CustomSens product. We are bringing a new range of sensors on to the market which |
Original | ||||
| th02 | FieldIT Data Sheet 10/11 8.19 EN Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Level 0: Information ■ Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0…5000 Ω) |
Original | ||||
| p | FieldIT Data Sheet 10/11 8.54 EN Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Level 0: Information ■ Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0…5000 Ω) |
Original | ||||
| 750-461 / 753-461 2-Channel Analog Input Module | 750-461 / 753-461 2-Channel Analog Input Module for RTDs 13 14 Function AI 1 Error AI 1 A C B Function AI 2 Error AI 2 D +R1 +R2 Data contacts 1 3-conductor +R 1 5 +R 1 +R 2 +R 2 +R RL1 RL2 270 pF 2 R1 RL 2 RL 1 R2 D 270 pF Logic Error Function 3 7 -R 1 -R 2 |
Original | ||||
| Platinum Temperature Sensors General Information | Platinum Temperature Sensors General Information In many industrial sectors and fields of research, temperature measurement is one of the most important parameters which determines product quality, security, and reliability. Temperature sensors are available in |
Original | ||||
|
|
||||||
| th202 | FieldIT Data Sheet 10/11 8.64 EN Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Level 0: Information ■ Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0…5000 Ω) |
Original | ||||
| tf12 | Data Sheet 10/11 8.26 EN FieldIT Temperature Transmitter, head mounted TF12/TF12-Ex PROFIBUS PA, Pt 100 (RTD), Thermocouples, 1 or 2 independent channels ■ Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling units |
Original | ||||
| 5425b | IBSL BOX TEMP 2/2 M12 INTERBUS Loop Box With Two Analog Input Channels for Measuring Temperature Signals Data Sheet 5425B 0 2 INTERBUS Loop can only be used in conjunction with a controller board having firmware version 4.15 or later. 0 1 IN O U T Function |
Original | ||||