Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PT 100 TEMPERATURE Search Results

    PT 100 TEMPERATURE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CO-316SMAX200-001
    Amphenol Cables on Demand Amphenol CO-316SMAX200-001 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 1ft PDF
    CO-316SMAX200-003
    Amphenol Cables on Demand Amphenol CO-316SMAX200-003 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 3ft PDF
    CO-316SMAX200-004
    Amphenol Cables on Demand Amphenol CO-316SMAX200-004 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 4ft PDF
    CO-316SMAX200-010
    Amphenol Cables on Demand Amphenol CO-316SMAX200-010 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 10ft PDF
    CO-316SMAX200-005
    Amphenol Cables on Demand Amphenol CO-316SMAX200-005 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 5ft PDF

    Documents mentioning PT 100 TEMPERATURE

    Document Partial File Text Tags Type PDF
    Analog Signal Conditioners EMA/PT 100
    Analog Signal Conditioners EMA/PT 100 RTD/Thermocouple 3-wire EG Housing Schematic Circuit Diagram Ordering Data Type G a l. No. Type C a t No. Type C a t No. EMA/PT 100 with 0.5% accuracy EMA/PT 100-U 116546 EMA/PT 100-1 116556 EMA/PT 100-1 116566 EMA/PT 100 with 0.1% accuracy
    OCR Scan PDF
    rl2006
    PTC THERMISTORS: SURFACE TEMPERATURE SENSORS PTC S urfa ce T em perature S ensors Tmw C V Type Number 30 40 45 65 RL2006-100-60-30-PT* SO 60 RL2006-100-70-30-PT* 70 85 RL2006-100-80-30-PT* 80 80 100 110 120 RL2006-100-30-30-PT* R L2006-100-40-30-PT* Resistance @ 25°C: 150Q max.
    OCR Scan PDF
    pt40f
    MINIBRIDGE 8 AMPERES-TAB TERMINALS SINGLE-PHASE FULL-WAVE BRIDGES HEAT SINK AND CHASSIS MOUNTING PT-F SERIES 600V PRV/Leg 50V 100 V 200V 400V Type No. PT 05 F PT 10F PT 20 F PT40F PT 60 F 800V 1000V PT 80 F PT 100 F ELECTRICAL CHARACTERISTICS PER LEG (at T a = 25°C Unless Otherwise Specified)
    OCR Scan PDF
    mcr-sl-pt100-sp
    MCR-SL-PT100-SP Thermostat for the PT-100 1. Description The MCR-SL-PT-100-SP thermostat module converts the measured values of the PT-100 sensor (IEC 751/ EN 60 751) into binary alarm switching signals. The sensor is supplied from the module with a low current. The resultant voltage drop is amplified in the
    Original PDF
    xa03
    www.crouzet.com "Application-specific" analogue extensions XA03 Part number 88970800 XA04W: Mix of inputs in the same casing: Pt 100, pH, ORP (Redox), Current (4 - 20 mA) XA03: 3 Pt 100 temperature inputs in the same casing "Application-specific" examples:
    Original PDF
    mcr-sl-pt100-sp
    MCR-SL-PT100-SP Thermostat for the PT-100 1. Description The MCR-SL-PT-100-SP thermostat module converts the measured values of the PT-100 sensor (IEC 751/ EN 60 751) into binary alarm switching signals. The sensor is supplied from the module with a low current. The resultant voltage drop is amplified in the
    Original PDF
    Configurable Temperature Measuring Transducers
    Configurable Temperature Measuring Transducers for PT 100 MCR-PT 100-… • Temperature range can be set using DIP switches • ZERO/SPAN adjustment • Open-circuit detection • Available with electrically isolated power supply ϑ U, I POWER 1. Description
    Original PDF
    mtw 12
    Intelligent interface modules Temperature modules for PT 100 Sensors MTW 12,4 MTW 12,4 2- 3-wire 4-wire Circuit diagram Input E1 PT 100 Output ϑ U ϑ E2 Technical data Supply voltage range Supply current Cable resistance (without PT100) Output signals Tolerance
    Original PDF
    sem205p
    ASSOCIATED PRODUCTS SEM205P ‘Smart’ Low cost Pt-100 in head Temperature transmitter The SEM205P accepts Pt-100 platinum resistance temperature sensors and converts the output to the 4-20mA industry standard. They are easily programmed using the software package RCPW running under Windows™
    Original PDF
    pt 100 temperature sensor
    with electronic components (other versions on request) DK 4 RC WDK 2.5 RC DK 4 PT 100 Arc suppression circuit for con­ tactors and solenoid valves (AC), protection module for optocoupler inputs PT 100 temperature sensor Dimensions DK 4/W DK 2.5 Length mm (in.)
    OCR Scan PDF
    ts 04
    TS 04 Head-mounted temperature transmitter, programmable via push-button, Pt 100 2/3-wire (RTD) 10/11-8.16 EN ■ Input – Pt 100 resistance thermometer (2-wire or 3-wire) ■ Output – 2-wire technique – 4…20 mA – Temperature-linear ■ Deviation 0.15 %
    Original PDF
    Terminal Blocks with Components Diodes BS r i DK
    Terminal Blocks with Components Diodes BS r i DK 4 D WDK 2.5 D DK 4 D WDK 2.5 D Diode terminal for lamp test Diode terminal for lamp test circuits, with series resistor circuits, with series resistor DK 4R C DK 4 PT 100 Arc suppression circuit PT 100 temperature sensor
    OCR Scan PDF
    Long cable application for Pt100 applications
    Long cable application for Pt100 applications Version : 1.1 Connection of Pt 100 with long cables. In standard UTI applications, the Pt 100 excitation is a square wave voltage between E and F (AC signal), via the series connection of Rbias and Rref (see UTI Data
    Original PDF
    powertech
    “BIG IDEAS IN BIG POWER " PowerTech ■ 10Q AMPERES F T -5501 PT-55Q2 SILICOIM INIPIN! TRANSISTORS MAXIMUM RATINGS SYMBOL Collector-Base Voltage V CBO Collector-Emitter Voltage PT-5501 PT-5502 80V 100 V 60V 80V 10V 10V 100A V CEO Emitter-Base Voltage V EBO
    OCR Scan PDF