Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PT 100 SENSOR TECH Search Results

    PT 100 SENSOR TECH Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCTH022BE
    Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function Datasheet
    TCTH021BE
    Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type Datasheet
    BQ20Z80DBTR-V110
    Texas Instruments SBS 1.1-Compliant Gas Gauge Enabled w/Impedance Track Tech 38-TSSOP -40 to 85 Visit Texas Instruments Buy
    BQ20Z80DBTR-V102
    Texas Instruments SBS 1.1-Compliant Gas Gauge Enabled w/Impedance Track Tech 38-TSSOP -40 to 85 Visit Texas Instruments Buy
    BQ20Z80DBT-V102
    Texas Instruments SBS 1.1-Compliant Gas Gauge Enabled w/Impedance Track Tech 38-TSSOP -40 to 85 Visit Texas Instruments Buy

    Documents mentioning PT 100 SENSOR TECH

    Document Partial File Text Tags Type PDF
    2024t
    R5 Technical Data Connector for Digitron Models 2024T & 2084T Suitable connector ( not supplied ) is RS 454-047 PT 100 probe connections as below. (View into rear of plug) Red Marker Dot White Wire ( sensor + ) White Wire ( supply + ) Pt 100 sensor 0) <u ■
    OCR Scan PDF
    mcr-sl-pt100-sp
    MCR-SL-PT100-SP Thermostat for the PT-100 1. Description The MCR-SL-PT-100-SP thermostat module converts the measured values of the PT-100 sensor (IEC 751/ EN 60 751) into binary alarm switching signals. The sensor is supplied from the module with a low current. The resultant voltage drop is amplified in the
    Original PDF
    mcr-sl-pt100-sp
    MCR-SL-PT100-SP Thermostat for the PT-100 1. Description The MCR-SL-PT-100-SP thermostat module converts the measured values of the PT-100 sensor (IEC 751/ EN 60 751) into binary alarm switching signals. The sensor is supplied from the module with a low current. The resultant voltage drop is amplified in the
    Original PDF
    ricos ricos Distributed I/O Modules PT/TC Modules
    ricos ricos Distributed I/O Modules PT/TC Modules 4 sensor inputs per module, self-setting to PT100/PT1000 sensors for 2-wire, 3-wire and 4-wire connection for thermocouples type J/K Dimensions (mm): W x H x D 69 x 92 x 51 Description Analog module 4 inputs PT 100/1000
    Original PDF
    balco
    PRECISION SENSING ELEMENT TYPE PT "Profit from PRECISION” BALCO® sensing element: • Type PT156 1000 ohm sensor is the ultimate in Balco technology with resistance tolerances to ±0.05% . • TCR char: +4300ppm/°C (±50ppm/°C) between 25°C and 100°C.
    OCR Scan PDF
    Temperature Measuring Amplifer for PT100 RTD’s
    Temperature Measuring Amplifer for PT100 RTD’s with/without Alarm Output The narrow 19mm DIN rail mountable measuring amplifier, accepts a signal from a PT-100 sensor (per DIN E C 751) and then linearizes, amplifies and adjusts it to a standard signal type e.g. 0..10V or
    OCR Scan PDF
    pt100
    RTD Thermocouple Conditioners • for 2 and 3 wire sensors MCZ PT100/3 CLP 0…100 °C / 0…120 °C / 0…150 °C / 0…200 °C / 0…300 °C -50…+150 °C / -40…100 °C The temperature module converts measurement values from a PT 100 into analogue measurement signals. The module supplies the sensor
    Original PDF
    ts 04
    TS 04 Head-mounted temperature transmitter, programmable via push-button, Pt 100 2/3-wire (RTD) 10/11-8.16 EN ■ Input – Pt 100 resistance thermometer (2-wire or 3-wire) ■ Output – 2-wire technique – 4…20 mA – Temperature-linear ■ Deviation 0.15 %
    Original PDF
    tr 104
    TR 104 / TR 104-Ex Rail mounted temperature transmitters, analog, Pt 100 (RTD), fixed measuring ranges 10/11-8.48 EN ■ Input – Resistance thermometer (2- and 3-wire circuit) – optionally 4-wire circuit ■ Output – 2-wire technique – 4…20 mA ■ 1 or 2 independent channels
    Original PDF
    microsens
    M I C R O S E N S Sensor Description Microsens Semiconductor Gas Sensor • MSGS 3000 Monosensor • MSGS 4000 Multisensor MSGS 3000 Gas sensor mounted on a standard TO type package Miniaturized semiconductor gas sensor are manufactured using standard microelectronic technology
    Original PDF
    mtw 12
    Intelligent interface modules Temperature modules for PT 100 Sensors MTW 12,4 MTW 12,4 2- 3-wire 4-wire Circuit diagram Input E1 PT 100 Output ϑ U ϑ E2 Technical data Supply voltage range Supply current Cable resistance (without PT100) Output signals Tolerance
    Original PDF
    pt8a2641
    Data Sheet PT8A2641-2642/2645-2648 PIR Sensor Light Switch PT Pericom Technology Inc. |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
    Original PDF
    PR-59 AND LT-INTERFACE USER MANUAL 1
    PR-59 AND LT-INTERFACE USER MANUAL 1 www.lairdtech.com Laird Technologies Table of Contents Section 1.0 – Introduction to LT-Interface and PR-59 …………………………………3 1.1 Introduction……………………………………………………………………3
    Original PDF
    WILLOW Technologies Sensors Thin Film Platinum
    WILLOW Technologies Sensors Thin Film Platinum Temperature Sensors Special developments include high temperature version up to 1000°C and low temperature version at -200°C. Please ask for details Ordering PT F C 101 B 000 1 2 3 4 5 6 Order Code Makeup 1) Platinum Series
    Original PDF
    ik 9094
    Monitoring technique Temperature monitoring relay IK 9094, IL 9094, SK 9094, SL 9094 varimeter • According to IEC/EN 60 255, DIN VDE 0435-303 • Devices available in 2 enclosure versions: I-model: depth 59 mm, with terminals at the bottom for installation systems and industrial distribution
    Original PDF
    platinum resistance temperature
    Platinum Resistance Temperature Detector HD 421 HD 421 Pt 100-type platinum temperature sensors are characterized by long-term stability, precision over a broad temperature range and compatibility. Main application area is the process technology. Nominal Resistance R0
    Original PDF
    thermometer
    FieldIT Data Sheet 10/10-3.61 EN Resistance thermometer TSBA (SensyTemp BA R) for building automation, machine construction and environmental engineering ■ Different output signals – Pt 100 signal – 4…20 mA, temperature linear, analog – 4…20 mA, HART protocoll (on request)
    Original PDF
    tshy
    FieldIT Data Sheet 10/10-3.64 EN Resistance thermometer TSHY (SensyTemp HY R) for the food and beverage industries for insertion in pipelines and vessels ■ Fast response – Halftime < 2.5 s ■ Various designs – Sensor smooth, with threaded compression fitting
    Original PDF
    5080c
    IB ST (ZF) 24 PT 100 4/4 Analog Input Module with 4 Channels for the Connection of Resistance Temperature Detectors (RTDs) 5080C000 Data Sheet 5080C 01/2000 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 F E
    Original PDF
    HybridPACK™ Hybrid Kit for HybridPACK™1
    HybridPACK™ Hybrid Kit for HybridPACK™1 Evaluation Kit for Applications with HybridPACK™1 Module Application Note V2.3, 2010-10-15 System Engineering Edition 2010-10-15 Published by Infineon Technologies AG 81726 Munich, Germany © 2010 Infineon Technologies AG
    Original PDF
    humidity sensor
    AB-5959 Specifications/Instructions Neosensor / Neomini Sensor Room Temperature / Humidity Sensor HTY70X3 / TY70X3 / HY70X3 General Room temperature/humidity sensor HTY70X3 series uses a Pt100 platinum film temperature sensing element and a polymer capacitive film humidity sensing element (FP3
    Original PDF
    tf12
    Data Sheet 10/11 8.26 EN FieldIT Temperature Transmitter, head mounted TF12/TF12-Ex PROFIBUS PA, Pt 100 (RTD), Thermocouples, 1 or 2 independent channels ■ Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling units
    Original PDF