Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    POLYSWITCH APPLICATION NOTES Search Results

    POLYSWITCH APPLICATION NOTES Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    PEF24628EV1X
    Rochester Electronics LLC PEF24628 - SOCRATES Four-channel SHDSL EFM system-on-chip PDF Buy
    143-4142-11H
    Amphenol Communications Solutions Paladin RPO, DC, 4-Pair, 4 Column, APP PDF
    143-6262-11H
    Amphenol Communications Solutions Paladin RPO, DC, 6-Pair, 6 Column, APP PDF
    144-411D-11H
    Amphenol Communications Solutions Paladin RPO, DO, 4-Pair, 10 Column, 1.5mm Wipe, APP PDF
    144-411G-21H
    Amphenol Communications Solutions Paladin RPO, DO, 4-Pair, 16 Column, 2.25mm Wipe, APP PDF

    POLYSWITCH APPLICATION NOTES Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    smd polyswitch fuse marking

    Abstract: x030 PolySwitch TS250-130-2 TR250-145 TYCO FUSE marking 72V TR250-120-2 GR-1089 GR-974 "Power over LAN" TR250-120
    Contextual Info: 2002-06-26 PRODUKTINFORMATION Vi reserverar oss mot fel samt förbehåller oss rätten till ändringar utan föregående meddelande ELFA artikelnr 60-269-83 PolySwitch TR250-080U 60-269-91 PolySwitch TR250-120 60-273-38 PolySwitch TR250-145 60-273-46 PolySwitch TR250-145U


    Original
    tr250-080utr250-120tr250-145tr250-145u+11tr250-180utr600-150ts250-130-2ts250-130rcsmd polyswitch fuse markingx030 polyswitchtyco fuse marking 72vtr250-120-2gr-1089gr-974power over lan PDF

    GR-1089

    Abstract: TR250-145 TSM600-250 TIA-968-A TR250 TR600 TVB170SA GR1089 Telcordia polyswitch 200
    Contextual Info: Telecommunications and Networking T1/E1 Equipment Application Overview Problem/Solution T1/E1 is a digital transmission link with a capacity of 1.544/2.048 Mbps. T1/E1 systems use two copper pairs and are used extensively for connecting networks across remote distances. Line repeaters


    Original
    gr-1089tsm600-250tvb170scts600-200-ra+12tvb170sbtr600-160tr600-160-raul1459/ul60950tr250-145tia-968-atr250tr600tvb170sagr1089telcordiapolyswitch 200 PDF

    TR250-145U-2 Raychem

    Abstract: TR250-145U-2 smd polyswitch fuse marking TLS250 x017 polyswitch TR250-120-2 x030 PolySwitch TSV250-130-2 miniSMDC014 TYCO FUSE marking 72V
    Contextual Info: Telecommunications and Networking PolySwitch Telecommunications and Networking Resettable Devices PolySwitch devices for telecommunication and networking applications were initially designed over ten years ago to meet the growing demand for resettable overcurrent protection. These


    Original
    tr250-145u-2 raychemtr250-145u-2smd polyswitch fuse markingtls250+6x017 polyswitchtr250-120-2x030 polyswitchtsv250-130-2minismdc014tyco fuse marking 72v PDF

    schematic circuit adsl modem

    Abstract: ADSL splitter circuit adsl modem circuit schematic BY 269V polyswitch ADSL FILTER GR-1089 TIA-968-A TR600 TVB270SA
    Contextual Info: Telecommunications and Networking ADSL Equipment Application Overview SiBar thyristors provide coordinated resettable protection against these faults, thereby protecting equipment from damage and minimizing field service and warranty costs. Problem/Solution


    Original
    144mbps640kbpsgr-1089tsm600-250-ra+15tvb270sctsm600ts600-200-ratvb270sbtr600-160-raul1459/ul60950schematic circuit adsl modemadsl splitter circuitadsl modem circuit schematicby 269vpolyswitchadsl filtertia-968-atr600tvb270sa PDF

    SRP350

    Abstract: LR4-190 LR4-260 SRP120 SRP175 SRP200 SRP420 TAC170-09 VTP210G polyswitch application notes
    Contextual Info: 2002-06-26 PRODUKTINFORMATION Vi reserverar oss mot fel samt förbehåller oss rätten till ändringar utan föregående meddelande ELFA artikelnr 60-274-03 PolySwitch SRP120 1,2A 60-274-11 PolySwitch SRP175 1,75A 60-274-29 PolySwitch SRP200 2,0A 60-274-37 PolySwitch SRP350 3,5A


    Original
    srp120srp175srp200srp350+6srp420tac170-09vtp210glr4-190lr4-260polyswitch application notes PDF

    TR250-145U-2 Raychem

    Abstract: TR250-145U-2 TR250-120-2 SMD050-2018-2 TSM600-250 RXE030 TS60060 tls250 TS60 TR250-120
    Contextual Info: Telecommunications and Networking PolySwitch Telecommunications and Networking Resettable Devices PolySwitch devices for telecommunication and networking applications were initially designed over ten years ago to meet the growing demand for resettable overcurrent protection. These


    Original
    tr250-145u-2 raychemtr250-145u-2tr250-120-2smd050-2018-2+6tsm600-250rxe030ts60060tls250ts60tr250-120 PDF

    polyswitch r110

    Abstract: polyswitch RUE 250 x030 PolySwitch x075 polyswitch RXE010 POLYSWITCH in ballast RXE050 RXE110 RXE017 POLYSWITCH 090
    Contextual Info: 2002-06-26 PRODUKTINFORMATION Vi reserverar oss mot fel samt förbehåller oss rätten till ändringar utan föregående meddelande ELFA artikelnr 60-270-07 60-270-15 60-270-23 60-270-31 60-270-49 60-270-56 60-270-64 60-270-72 60-270-80 60-270-98 60-271-06


    Original
    rxe010100marxe017170ma+14rxe020200marxe025250marxe030300mapolyswitch r110polyswitch rue 250x030 polyswitchx075 polyswitchpolyswitch in ballastrxe050rxe110polyswitch 090 PDF

    036 84, 036 85, 036 86 rondorex w21

    Abstract: LR4-550 MINISMDE190-2 raychem SRP175 VTP210G-2 LR4-450 raychem E55 LR4-190 B4B1 SRP200
    Contextual Info: Strap Battery PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection, pioneer of polymeric PTC resettable devices, has developed several material platforms specifically tailored to help protect battery applications. Each of these material platforms offers different performance characteristics,


    Original
    036 84, 036 85, 036 86 rondorex w21lr4-550minismde190-2raychem srp175+6vtp210g-2lr4-450raychem e55lr4-190b4b1srp200 PDF

    250v 2A t11

    Abstract: "Power over LAN" smd polyswitch fuse marking MINISMDC014F-2 120T2 polyswitch tr250-90
    Contextual Info: Telecommunications and Networking PolySwitch Telecommunications and Networking Resettable Devices PolySwitch devices for telecommunication and networking applications were initially designed over ten years ago to meet the growing demand for resettable overcurrent protection. These


    Original
    250v 2a t11power over lansmd polyswitch fuse markingminismdc014f-2+2120t2polyswitch tr250-90 PDF

    AC170

    Abstract: SRP350 LR4-190 LR4-260 SRP200 SRP420 TAC100-09 TAC170-09 TAC210 VTP170
    Contextual Info: Strap Battery PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection, pioneer of polymeric PTC resettable devices, has developed several material platforms specifically tailored to help protect battery applications. Each of these material platforms offers different performance characteristics,


    Original
    ac170srp350lr4-190lr4-260+6srp200srp420tac100-09tac170-09tac210vtp170 PDF

    usb/PAL 0073 pioneer

    Abstract: DIODE smd marking s4 82a x160 protector smd polyswitch fuse marking
    Contextual Info: Circuit Protection Products Catalog 2013-2014 • Overtemperature Protection • Overvoltage Protection • Overcurrent Protection • Hybrid Protection 2013_CP_Cover_OFC-OBC-Spine-2013-14.indd 3 8/22/13 4:07 PM This catalog is intended to present application, product, and technical data to assist the user in selecting circuit


    Original
    ofc-obc-spine-2013-14usb/pal 0073 pioneerdiode smd marking s4 82ax160 protector+1smd polyswitch fuse marking PDF

    E19-E26

    Abstract: PSR-23096 vtp210s polyswitch E73 PSR-22631 MINISMDE190-2
    Contextual Info: Strap Battery PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection, pioneer of polymeric PTC resettable devices, has developed several material platforms specifically tailored to help protect battery applications. Each of these material platforms offers different performance characteristics,


    Original
    e19-e26psr-23096vtp210spolyswitch e73+2psr-22631minismde190-2 PDF

    PolySwitch Resettable Fuse

    Abstract: TVB200SC GR-1089 TR250 TR600-150 TR600-160-RA TS600-170 TS600-200-RA rebb TVB270SA
    Contextual Info: SiBar Thyristor Surge Protectors SA and SC series thyristor products for overvoltage protection SiBar thyristor surge protectors provide transient voltage protection for telecommunications applications. Tyco Electronics SiBar thyristor surge protectors are designed to


    Original
    rcp0023polyswitch resettable fusetvb200scgr-1089+7tr250tr600-150tr600-160-rats600-170ts600-200-rarebbtvb270sa PDF

    varistor k35

    Abstract: Polyswitch R600 22B2 DIODE 250V, 200mA, PTC resettable fuse polyswitch 500ma TR250 TR250-120 TR250-120T TS250-130 TSV250-130
    Contextual Info: ITU-T Recommendations Application Note 3 Telecommunication equipment has become ever more sensitive to overvoltage and overcurrent hazards on telephone lines. Conventional transformer-based architectures have been replaced by sensitive IC-based architectures. At the same time, the


    Original
    varistor k35polyswitch r60022b2 diode250v, 200ma, ptc resettable fuse+6polyswitch 500matr250tr250-120tr250-120tts250-130tsv250-130 PDF

    GTCA28-421M-R10

    Abstract: electronic schematic
    Contextual Info: PolySwitch PTC Devices PRODUCT: TRF250-184 DOCUMENT: SCD27165 REV LETTER: D REV DATE: May 12, 2011 PAGE NO.: Page 1 of 2 Overcurrent Protection Device 308 Constitution Drive Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com Specification Status: Released


    Original
    trf250-184scd27165100vdc10arms+3gr1089gtca28-421m-r10electronic schematic PDF

    TVB200SA

    Abstract: REBB GR-1089 TR250 TVB170SA TVB170SC TVB200SC TVB270SA TVB270SC resettable circuit protector
    Contextual Info: SiBar Thyristor Surge Protectors SA and SC series thyristor products for overvoltage protection SiBar thyristor surge protectors provide transient voltage protection for telecommunications applications. Tyco Electronics SiBarTM thyristor surge protectors are designed to


    Original
    rcp0023tvb200sarebbgr-1089+7tr250tvb170satvb170sctvb200sctvb270satvb270scresettable circuit protector PDF

    RXE030

    Abstract: GR-1089 RXE050 SMD030 SMD030-2018 SMD050 telephone POLYSWITCH telcordia gr-1089 polyswitch application notes
    Contextual Info: PBX and Key Telephone Systems Application Overview Problem/Solution 3 Both PBX and key telephone systems contain components that may be damaged by overcurrent or overvoltage conditions resulting from installation errors, component failure, or misuse. Some


    Original
    -48vdc48vdcul60950tia-968-a+10gr-1089rxe030rxe050smd030smd030-2018smd050telephonepolyswitchtelcordia gr-1089polyswitch application notes PDF

    polyswitch application notes

    Abstract: VLP270 VLR175 LR4-260 SRP175 TAC170-09 VLP210 VLR230 VTP170 VTP210G
    Contextual Info: Strap Battery PolySwitch Strap Battery Resettable Devices Raychem Circuit Protection, pioneer of polymeric PTC resettable devices, has developed several material platforms specifically tailored to help protect battery applications. Each of these material platforms offers different performance characteristics,


    Original
    polyswitch application notesvlp270vlr175lr4-260+6srp175tac170-09vlp210vlr230vtp170vtp210g PDF

    TVB200SA

    Abstract: TS250-130-RA GR-1089 TIA-968-A TR250 TR600 GR1089 polyswitch 200
    Contextual Info: Telecommunications and Networking HDSL Equipment Application Overview Problem/Solution High-bit-rate Digital Subscriber Line HDSL technology is a transparent replacement for a T1 repeatered line in the distribution plant. It allows two-way transmission rates of 1.544Mbps (DS-1)


    Original
    544mbpsgr-1089tsm600tvb200sc+11ts600-200-ratvb200sbtrf600-150tr600-160-ratvb200sats250-130-ratia-968-atr250tr600gr1089polyswitch 200 PDF

    30V U135

    Abstract: polyswitch r110 POLYSWITCH u090 raychem x065 polyswitch u110 polyswitch u250 polyswitch 30 u250 U185 U300 U135
    Contextual Info: Radial-leaded PolySwitch Radial-leaded Resettable Devices Raychem Circuit Protection has pioneered PPTC technology for over twenty years. Our radialleaded products represent the widest range of product capabilities. • RGE series for hold currents up to 14A


    Original
    ieee-1394tr600tr25030v u135+9polyswitch r110polyswitch u090raychem x065polyswitch u110polyswitch u250polyswitch 30 u250u185u300u135 PDF

    30V U135

    Abstract: POLYSWITCH in ballast POLYSWITCH u090 raychem RUE 090 X075 30V U600 U185 polyswitch r110 polyswitch u250 polyswitch u600
    Contextual Info: Radial-leaded PolySwitch Radial-leaded Resettable Devices Raychem Circuit Protection has pioneered PPTC technology for over twenty years. Our radialleaded products represent the widest range of product capabilities. • RGE series for hold currents up to 14A


    Original
    ieee-1394tr600tr25030v u135+9polyswitch in ballastpolyswitch u090raychem rue 090x07530v u600u185polyswitch r110polyswitch u250polyswitch u600 PDF

    POLYSWITCH u090

    Abstract: polyswitch u250 U185 30V U135 polyswitch u110 polyswitch marking X-185 U160 RUE600K G1200
    Contextual Info: Radial-leaded PolySwitch Radial-leaded Resettable Devices 4 Raychem Circuit Protection has pioneered PPTC technology for over twenty years. Our radialleaded products represent the widest range of product capabilities. • RGE series for hold currents up to 14A


    Original
    ieee-1394tr600tr250polyswitch u090+9polyswitch u250u18530v u135polyswitch u110polyswitch markingx-185u160rue600kg1200 PDF

    tyco usb

    Abstract: ZEN056V130A24LS tyco USB connector Wireless USB Hub polyswitch 500ma ZEN056V230A16LS ZEN059V130A24LS PC hdd CIRCUIT diagram specification requirements usb 3.0 usb interference circuit diagram
    Contextual Info: APPLICATION NOTE USB 2.0 and USB 3.0 Circuit Protection Considerations for Hard Disc Drives Although power via USB has been in use for some time, the growing use of USB-based external Hard Disc Drives HDDs , including external-powered-type, USB-powered-type and now


    Original
    rcp0096etyco usbzen056v130a24lstyco usb connector+7wireless usb hubpolyswitch 500mazen056v230a16lszen059v130a24lspc hdd circuit diagramspecification requirements usb 3.0usb interference circuit diagram PDF

    smd diode marking code t056

    Abstract: xf075 xf017 tyco igbt module 25A Thermistor PTC 265V* xf017 XF090 raychem* XF090 xf065 PolySwitch Resettable Devices xf250 PTC XF010
    Contextual Info: Circuit Protection Business Unit Headquarters 308 Constitution Drive, Building H Menlo Park, CA USA 94025-1164 Tel : 800 227-7040, (650) 361-6900 Fax : (650) 361-4600 www.circuitprotection.com www.circuitprotection.com.hk (Chinese) www.tycoelectronics.com/japan/raychem (Japanese)


    Original
    886-2-876osercp0060esmd diode marking code t056xf075+8xf017tyco igbt module 25athermistor ptc 265v* xf017xf090raychem* xf090xf065polyswitch resettable devices xf250ptc xf010 PDF