    DCL541A01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable Datasheet
    DCL541B01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable Datasheet
    DCM341B01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=3.0~5.5V / 50Mbps / 4 channel(F:R=3:1) / Default Output Logic: High / Input disable / AEC-Q100 Datasheet
    DCM341A01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=3.0~5.5V / 50Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable / AEC-Q100 Datasheet
    TC75S102F
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 1.5V to 5.5V, I/O Rail to Rail, IDD=0.27μA, SOT-25 Datasheet

    Documents mentioning PLC INPUT OUTPUTS

    Document Partial File Text Tags Type PDF
    1771
    PLC4000 SERIES 120 WATT DC-DC POWER SUPPLY FOR THE ALLEN BRADLEY 1771 PLC SYSTEM FEATURES • Active Current Sharing Full Redundant Operation Hot Swap Capability Remote Sense Input Input Power: 215 watts max. Status Alarm: Signals PLC if input voltage drops below specified
    Original PDF
    2.2 Product Profile and Outline FUNCTION
    2.2 Product Profile and Outline FUNCTION SPECIFICATION 3 7 3.1 Function Specification 1-phase Input 10 Item 1 Input 1 High-speed Counter Module 2 Max. Number of Connecting Units 8 3 Instruction Sheet 5 7 3 6 This is an OPEN TYPE PLC. The PLC should be kept in an enclosure away from airborne
    Original PDF
    Models 8508,8509,8510,8513 & 8514 PLC Frequency
    Models 8508,8509,8510,8513 & 8514 PLC Frequency to Analog I/O Modules Features D escription ■ Current or Voltage Output These frequency to analog converters are designed to operate from the common 24 V o lt, 7mA PLC discrete outputs or any source that can switch 7mA through 3000 ohms. Their input
    OCR Scan PDF
    Models 8508, 8509, 8510, 8513 & 8514 PLC
    Models 8508, 8509, 8510, 8513 & 8514 PLC Frequency to Analog I/O Modules Features Description n Current or Voltage Output n Compatible with 24 Volt PLC Discrete High Speed Counter Output n 2000 Hz or 5000 Hz Full Scale n Isolated Input to Output n High Resolution
    Original PDF
    8555
    Model 8555 Strain Gage to Frequency Model 8555 analog to frequency converter offers a cost effective solution for a single or multiple channel PLC I/O system. It is designed to operate into the PLC high speed counter inputs. The input range of 0 to 50mV makes the 8555
    Original PDF
    cpm
    Compact PLC Series CPM2C Programmable Logic Contr. General The CPM2C Micro PLC is suitable as a controller for simple stand−alone machines, as well as a simple networked controller. One innovation is the new synchronisation instruction, which makes it possible to generate output pulse trains as a function of an input pulse
    Original PDF
    strain gage
    prelîni*narY Model 8555 Strain Gage to Frequency I/O Module Features Description ■ 0 to 50 mV differential Analog Input These analog to frequency converters offer a cost effective solution for a single or multiple channel PLC I/O system. They are designed to operate into the PLC high speed counter
    OCR Scan PDF
    Maxim > Design Support > Technical Documents >
    Maxim > Design Support > Technical Documents > Sub-System Boards > APP 5611 Keywords: Corona, MAXREFDES12, subsystem reference design, digital input translator/serializer, digital input modules, PLC, home automation, industrial automation, process automation, motor control, isolated power and data
    Original PDF
    : Right limit input indicator ΦA : A-phase input
    : Right limit input indicator ΦA : A-phase input of manual pulse generator Item LSN : Left limit input indicator ΦB : B-phase input of manual pulse generator : Zero signal input indicator CLR : Output clear signal Connect to DVP-PLC in series 3 Do NOT touch terminals when power on. Please turn off the power before wiring.
    Original PDF
    2. The AC power input for PLC MPU and I/O
    2. The AC power input for PLC MPU and I/O extension modules should be ON or OFF at the same time. 3. Use wires of 1.6mm (or longer) for the grounding. The power shutdown of less than 10ms will not affect the operation of the PLC. However, power shutdown time that is too long or the drop of power voltage will stop
    Original PDF
    cj1w-id
    CJ-series Input Units CJ1W-ID/IA CSM_CJ1W-INPUT_DS_E_5_1 A Wide Range of Basic Input Units for High Speed Input and Different Applications • Receive ON/OFF signals from external devices into the PLC System to update I/O memory in the CPU Unit. • New high-speed input models CJ1W-ID212 and
    Original PDF
    cj1w-id
    SYSMAC CJ-series Input Units CJ1W-ID/IA CSM_CJ1W-INPUT_DS_E_4_1 A Wide Range of Basic Input Units for High Speed Input and Different Applications • Receive ON/OFF signals from external devices into the PLC System to update I/O memory in the CPU Unit. • New high-speed input models CJ1W-ID212 and
    Original PDF
    Preliminary Model 8555 Strain Gage to Frequency
    Preliminary Model 8555 Strain Gage to Frequency I/O Module Features Description n 0 to 50 mV differential Analog Input n Frequency Output to 5 kHz n Compatible with PLC High Speed Counter Inputs n Includes 10V Excitation Supply n Isolated Input to Output n
    Original PDF
    Maxim > App Notes > A/D and D/A
    Maxim > App Notes > A/D and D/A Conversion/Sampling Circuits Amplifier and Comparator Circuits Hot-Swap and Power Switching Circuits Sensor Signal Conditioners Keywords: PLC, programmable logic controller, industrial controls, fieldbus, analog input, analog output, Profibus,
    Original PDF
    8508
    Models 8508, 8509, 8510, 8513, 8514 Frequency to Analog Models 8508, 8509, 8510, 8513 and 8514 frequency to analog converters are designed to operate from the common 24 Volt , 7mA PLC discrete outputs or any source that can switch 7mA through 3000 ohms. Their input is an isolated
    Original PDF
    ad7192
    4.8 kHz, Ultralow Noise, 24-Bit Sigma-Delta ADC with PGA AD7192 FEATURES Temperature measurement Chromatography PLC/DCS analog input modules Data acquisition Medical and scientific instrumentation RMS noise: 11 nV @ 4.7 Hz (gain = 128) 15.5 noise-free bits @ 2.4 kHz (gain = 128)
    Original PDF
    4.8 kHz, Ultralow Noise, 24-Bit Sigma-Delta ADC
    4.8 kHz, Ultralow Noise, 24-Bit Sigma-Delta ADC with PGA and AC Excitation AD7195 FEATURES Chromatography PLC/DCS analog input modules Data acquisition Medical and scientific instrumentation AC or DC sensor excitation RMS noise: 8.5 nV at 4.7 Hz (gain = 128)
    Original PDF
    Ultrasonic Evaluation Unit for Sensor Head Type
    Ultrasonic Evaluation Unit for Sensor Head Type UC EU 80 -1 • 100 x 75 x 110 mm housing, DIN-rail mounting • Outputs: PLC, Display, RS232, sensor supply • Input: Sensor head UC 80 CND 80 FS M1 • Full programmable • Hold function, 2 set points, over- and under range,
    Original PDF