Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PILZ CATEGORY 3 Search Results

    PILZ CATEGORY 3 Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-5XRJ45UNNE-007
    Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-007 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 7ft PDF
    MP-5XRJ45UNNE-005
    Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-005 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 5ft PDF
    MP-5XRJ45UNNE-025
    Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-025 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 25ft PDF
    MP-5XRJ45UNNE-010
    Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-010 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 10ft PDF
    MP-5XRJ45UNNE-003
    Amphenol Cables on Demand Amphenol MP-5XRJ45UNNE-003 Category 5E 3/4/176900Base-T Crossover Cable, RJ45 / RJ45 3ft PDF

    PILZ CATEGORY 3 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    PILZ pnoz e3.1p

    Abstract: PILZ pnoz m1p PNOZ s4 pnoz m1p PILZ pnoz x4 PNOZ M1P serial cable pilz PNOZ X3P pnoz.x2.8p PILZ pnoz s11 PNOZ mc8p
    Contextual Info: IE NZ Pilz GmbH & Co. KG Sichere Automation Felix-Wankel-Straße 2 73760 Ostfildern Germany Telephone: +49 711 3409-0 Telefax: +49 711 3409-133 E-Mail: pilz.gmbh@pilz.de Pilz Ireland Industrial Automation Cork Business and Technology Park Model Farm Road


    Original
    PDF

    pilz pnoz xv3

    Abstract: pnoz xv3 PILZ pnoz Pilz pnoz xv3 safety relay Pilz safety relay PNOZ XV3.1 774540 PILZ pnoz 5 Pilz Pnoz v Pilz safety relay PNOZ XV3
    Contextual Info: E-STOP relays, safety gate monitors Up to Category 4, EN 954-1 PNOZ XV3 Unit features Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals PNOZ XV3 ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 2 safety contacts (N/O), delay-on


    Original
    NSG-D-2-248-2008-09 pilz pnoz xv3 pnoz xv3 PILZ pnoz Pilz pnoz xv3 safety relay Pilz safety relay PNOZ XV3.1 774540 PILZ pnoz 5 Pilz Pnoz v Pilz safety relay PNOZ XV3 PDF

    PNOZ 2VQ

    Abstract: 774013 Pilz safety relay PILZ pnoz 15 S21-S52 S11-S12 pnoz DC124 pnoz 6 pnoz v
    Contextual Info: E-STOP relays, safety gate monitors Category 4, EN 954-1 PNOZ 2VQ Unit features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 2 safety contacts (N/O), delay-on de-energisation – 1 auxiliary contact (N/C), instantaneous ` Connection options for:


    Original
    NSG-D-2-063-2010-06 PNOZ 2VQ 774013 Pilz safety relay PILZ pnoz 15 S21-S52 S11-S12 pnoz DC124 pnoz 6 pnoz v PDF

    pnoz x1

    Abstract: PILZ PNOZ X1 pilz pnoz 1 en 954-1 PILZ pnoz PILZ pnoz 10 PNOZ 10
    Contextual Info: E-STOP relays up to Category 2, EN 954-1 PNOZ X1 Safety relay for monitoring E-STOP pushbuttons. Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` Safe separation of safety contacts


    Original
    NSG-D-2-069-2006-09 pnoz x1 PILZ PNOZ X1 pilz pnoz 1 en 954-1 PILZ pnoz PILZ pnoz 10 PNOZ 10 PDF

    PILZ pnoz x3

    Abstract: PILZ PNOZ X3 safety relay pnoz x3 Pilz safety relay Pilz safety relay pnoz x3 PILZ pnoz s11 pilz x3 19968 Pilz PILZ pnoz pilz pnoz 1
    Contextual Info: E-STOP relays, safety gate monitors Ke i n G er ät eb ild vo rh an de n Category 4, EN 954-1 PNOZ X3.2 Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals PNOZ X3.2 Unit features ` Safety gates ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous


    Original
    NSG-D-2-356-2010-01 PILZ pnoz x3 PILZ PNOZ X3 safety relay pnoz x3 Pilz safety relay Pilz safety relay pnoz x3 PILZ pnoz s11 pilz x3 19968 Pilz PILZ pnoz pilz pnoz 1 PDF

    PNOZ XV3.1

    Abstract: pilz pnoz xv3 pilz pnoz x 3.1 PILZ xv3.1 PILZ pnoz s11 pilz pnoz xv3.1 pnoz s3 S11-S12 PILZ pnoz e breaker
    Contextual Info: E-STOP relays, safety gate monitors Up to Category 4, EN 954-1 PNOZ XV3.1 Unit features Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals PNOZ XV3.1 ‹ ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 2 safety contacts (N/O), delay-on


    Original
    NSG-D-2-297-2008-08 PNOZ XV3.1 pilz pnoz xv3 pilz pnoz x 3.1 PILZ xv3.1 PILZ pnoz s11 pilz pnoz xv3.1 pnoz s3 S11-S12 PILZ pnoz e breaker PDF

    PILZ pze x4

    Abstract: Pilz safety relay PZE 9 pilz pze 7 PILZ pze 9 PZE x4 Pilz safety relay pnoz x4 PILZ pnoz x4 PILZ PNOZ X4 safety relay 24 VDC PILZ PNOZ X4 safety relay Pilz safety relay
    Contextual Info: Expander modules Instantaneous PZE X4 Unit features Safety features ` Positive-guided relay outputs: – 4 safety contacts N/O , instantaneous ` Safe separation of safety contacts 13-14, 23-24, 33-34 from input circuit A1 and feedback loop Y1-Y2 ` Connection for feedback loop


    Original
    NSG-D-2-091-2010-08 PILZ pze x4 Pilz safety relay PZE 9 pilz pze 7 PILZ pze 9 PZE x4 Pilz safety relay pnoz x4 PILZ pnoz x4 PILZ PNOZ X4 safety relay 24 VDC PILZ PNOZ X4 safety relay Pilz safety relay PDF

    PILZ pnoz x3

    Abstract: PILZ PNOZ X3 safety relay pnoz X3 pilz x3 19968 Pilz safety relay x3 PILZ pnoz Pilz safety relay pnoz x3 Pilz safety relay pnoz x3 s PILZ pnoz s11 774-314
    Contextual Info: E-STOP relays, safety gate monitors Up to Category 4, EN 954-1 PNOZ X3 Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous


    Original
    NSG-D-2-036-2010-01 PILZ pnoz x3 PILZ PNOZ X3 safety relay pnoz X3 pilz x3 19968 Pilz safety relay x3 PILZ pnoz Pilz safety relay pnoz x3 Pilz safety relay pnoz x3 s PILZ pnoz s11 774-314 PDF

    PNOZ X6

    Abstract: PILZ PNOZ X6 safety relay Pilz safety relay PILZ pnoz PILZ pnoz 10 600-068 PILZ pnoz s11 S11-S12
    Contextual Info: E-STOP relays, safety gate monitors Up to Category 3, EN 954-1 PNOZ X6 Unit features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous ` Connection options for: – E-STOP pushbutton – Safety gate limit switch – Reset button ` LED indicator for:


    Original
    NSG-D-2-047-01/05 PNOZ X6 PILZ PNOZ X6 safety relay Pilz safety relay PILZ pnoz PILZ pnoz 10 600-068 PILZ pnoz s11 S11-S12 PDF

    pilz pnoz xv3

    Abstract: pnoz xv3 S31-S32 D 650 S14 Pilz safety relay PNOZ XV3 PILZ pnoz PILZ pnoz 10 Pilz safety relay S11-S12 Klemmenbelegung
    Contextual Info: E-STOP relays, safety gate monitors Up to Category 4, EN 954-1 PNOZ XV3.3P Unit features Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 2 safety contacts (N/O), delay-on


    Original
    NSG-D-2-353-12/04 pilz pnoz xv3 pnoz xv3 S31-S32 D 650 S14 Pilz safety relay PNOZ XV3 PILZ pnoz PILZ pnoz 10 Pilz safety relay S11-S12 Klemmenbelegung PDF

    PMUT

    Abstract: t5 s61 PMUT X1P s3-24v sensor s52 S12S51 VAC s4 p5 PMUT-X1P outputY32
    Contextual Info: Muting controller Up to Category 4, EN 954-1 PMUT X1P Unit features – Light barrier ESPE active ` Plug-in connection terminals (either spring-loaded terminal or screw terminal) ` See order reference for unit types ` Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous


    Original
    NSG-D-2-305-2010-08 PMUT t5 s61 PMUT X1P s3-24v sensor s52 S12S51 VAC s4 p5 PMUT-X1P outputY32 PDF

    pnoz v

    Abstract: pnoz-v PILZ pnoz v S25000 pilz pnoz 1 3 category S11-S12 "pnoz v" pnoz PILZ pnoz e
    Contextual Info: E-STOP relays, safety gate monitors Up to Category 3, EN 954-1 PNOZ V Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 safety contact (N/O), delay-on de-energisation – 1 auxiliary contact (N/C), instantaneous


    Original
    NSG-D-2-322-2010-07 pnoz v pnoz-v PILZ pnoz v S25000 pilz pnoz 1 3 category S11-S12 "pnoz v" pnoz PILZ pnoz e PDF

    PILZ pze x4

    Abstract: PILZ pnoz x4 pnoz X4 ossd output Pilz safety relay pnoz x4 pnoz 1 Pilz safety relay PILZ pnoz 10 u 711 PILZ PNOZ mm0.1p
    Contextual Info: Contact expansion modules Up to PL e of EN ISO 13849-1 PZE X4.1P Unit features ` Positive-guided relay outputs: – 4 safety contacts N/O , instantaneous ` Safe separation of safety contacts 13-14, 23-24, 33-34 from input circuits K1-U-K2 and feedback loop


    Original
    NSG-D-2-351-2010-01 PILZ pze x4 PILZ pnoz x4 pnoz X4 ossd output Pilz safety relay pnoz x4 pnoz 1 Pilz safety relay PILZ pnoz 10 u 711 PILZ PNOZ mm0.1p PDF

    p2hz x1

    Abstract: PILZ P2HZ PILZ P2HZ X1 safety relay PILZ X1 pilz 20510 PILZ p2hz x1 P2HZ 3 S11-S12-S13 S21-S22-S23 PILZ relay
    Contextual Info: Two-hand control unit Requirement class IIIC, EN 574 P2HZ X1 ` Safety circuits in accordance with EN 60204-1 Unit features Two-hand control unit for press controllers and safety circuits ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous


    Original
    cont760 NSG-D-2-078-01/05 p2hz x1 PILZ P2HZ PILZ P2HZ X1 safety relay PILZ X1 pilz 20510 PILZ p2hz x1 P2HZ 3 S11-S12-S13 S21-S22-S23 PILZ relay PDF

    pilz pze 7

    Abstract: pze 7 pilz "pze 7" pilz block diagram
    Contextual Info: Expander modules Delayed PZE X5V Unit features The delay-on de-energisation safety contacts may only be used up to category 3. ` Positive-guided relay outputs: – 5 safety contacts N/O , delay-on de-energisation ` Cancellation of delay time ` LED indicator for:


    Original
    feedbackP20 NSG-D-2-251-2010-06 pilz pze 7 pze 7 pilz "pze 7" pilz block diagram PDF

    PILZ P2HZ

    Abstract: P2HZ PILZ P2HZ X1P EN574 "Y35" P2HZ 3 P2HZ 2 S11-S12-S13 SIS212 Pilz safety relay
    Contextual Info: Two-hand control unit Up to PL e of EN ISO 13849-1 P2HZ X1P Unit features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` 2 semiconductor outputs ` Connection options for: – 2 operator elements (buttons)


    Original
    NSG-D-2-163-2010-09 PILZ P2HZ P2HZ PILZ P2HZ X1P EN574 "Y35" P2HZ 3 P2HZ 2 S11-S12-S13 SIS212 Pilz safety relay PDF

    pilz pu3z

    Abstract: PU3Z Y43-Y44 NSG-D-2-243-2006-11 x103f
    Contextual Info: Safe monitoring relays Voltage PU3Z Voltage monitoring relay for the safe monitoring of 3-phase supplies Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous


    Original
    NSG-D-2-243-2006-11 pilz pu3z PU3Z Y43-Y44 NSG-D-2-243-2006-11 x103f PDF

    PNOZ s4

    Abstract: PNOZ s4 C Pilz pnoz s4 PILZ pnoz 751104 Pilz Pnoz 751 104 Pilz pnoz S4 B10d Pilz Pnoz 750 104 Pilz PSEN S3 Pilz safety relay pnoz s4 pnozs4
    Contextual Info: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ s4 Unit features Unit description ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` 1 semiconductor output ` Connection options for:


    Original
    1001742-EN-03-2010-11 PNOZ s4 PNOZ s4 C Pilz pnoz s4 PILZ pnoz 751104 Pilz Pnoz 751 104 Pilz pnoz S4 B10d Pilz Pnoz 750 104 Pilz PSEN S3 Pilz safety relay pnoz s4 pnozs4 PDF

    PNOZ X1

    Abstract: PILZ pnoz 9 PILZ PNOZ Z 24 V PILZ PNOZ X1 pilz pnoz 1 3 category PILZ pnoz 10 DC-13 pnoz 8 pilz pnoz 1 24v Pilz safety relay
    Contextual Info: E-STOP relays Up to PL e of EN ISO 13849-1 PNOZ X1 Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` Safe separation of safety contacts 13-14, 23-24, 33-34 from input circuits A1-A2, feedback loop Y1-Y2


    Original
    NSG-D-2-069-2010-08 PNOZ X1 PILZ pnoz 9 PILZ PNOZ Z 24 V PILZ PNOZ X1 pilz pnoz 1 3 category PILZ pnoz 10 DC-13 pnoz 8 pilz pnoz 1 24v Pilz safety relay PDF

    pnoz X2.9P

    Abstract: Y36-Y37 PILZ pnoz x2.9p S12-S34 Pilz safety relay PNOZ s2 pnoz X2 PILZ pnoz 61511 NSG-D-2-354-2010-01
    Contextual Info: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X2.9P Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` Connection options for: – E-STOP pushbutton


    Original
    NSG-D-2-354-2010-01 pnoz X2.9P Y36-Y37 PILZ pnoz x2.9p S12-S34 Pilz safety relay PNOZ s2 pnoz X2 PILZ pnoz 61511 NSG-D-2-354-2010-01 PDF

    PILZ pnoz X1P

    Abstract: Pilz safety relay PILZ pnoz 10 Pilz 61511 pnoz v pnoz x1p iso manual
    Contextual Info: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X1P Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` Connection options for: – E-STOP pushbutton


    Original
    NSG-D-2-335-2009-11 PILZ pnoz X1P Pilz safety relay PILZ pnoz 10 Pilz 61511 pnoz v pnoz x1p iso manual PDF

    Pilz pnoz s4

    Abstract: Pilz pnoz s9 PNOZ s4 PILZ pnoz pst PILZ PNOZ e1p Pnoz S9 Pilz pnoz s5 pnoz s5 pnoz X PILZ P2HZ
    Contextual Info: Safe timer relay/contact expansion modules up to PL e of EN ISO 13849-1 PNOZ s9 Unit features ` Positive-guided relay outputs, either instantaneous, delay-on deenergisation also retriggerable , pulsing or delay-on energisation: – 3 safety contacts – 1 auxiliary contact


    Original
    NSG-D-2-400-2010-08 Pilz pnoz s4 Pilz pnoz s9 PNOZ s4 PILZ pnoz pst PILZ PNOZ e1p Pnoz S9 Pilz pnoz s5 pnoz s5 pnoz X PILZ P2HZ PDF

    PILZ P2HZ

    Abstract: PILZ P2HZ x4 P2HZ X3 P2HZ X4 P2HZ p2hz x1 mm2 relay S11-S12-S13 SIS212 S21-S22-S23
    Contextual Info: Two-hand control unit Up to PL e of EN ISO 13849-1 P2HZ X1.10P Unit features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` 2 semiconductor outputs ` Connection options for: – 2 operator elements (buttons)


    Original
    NSG-D-2-324-2010-09 PILZ P2HZ PILZ P2HZ x4 P2HZ X3 P2HZ X4 P2HZ p2hz x1 mm2 relay S11-S12-S13 SIS212 S21-S22-S23 PDF

    PNOZ s7

    Abstract: PILZ PNOZ S7 pilz pnoz 1 24v PILZ PNOZ S7 750107 Pilz 751107 PNOZ S7 Pilz Relay DC-13 pnozs 750107 Pilz safety relay
    Contextual Info: Contact expansion modules Up to PL e of EN ISO 13849-1 PNOZ s7 Unit features ` Positive-guided relay outputs: – 4 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` Safe separation of safety contacts 13-14, 23-24, 33-34 from all other


    Original
    011within NSG-D-2-398-2010-09 PNOZ s7 PILZ PNOZ S7 pilz pnoz 1 24v PILZ PNOZ S7 750107 Pilz 751107 PNOZ S7 Pilz Relay DC-13 pnozs 750107 Pilz safety relay PDF