Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PICKUP COIL E Search Results

    PICKUP COIL E Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    10121749-002CLF
    Amphenol Communications Solutions Extended Height 12G SCA2 Fiber Channel Receptacle 40 Position, SMT, Lead-Free, with pickup cap PDF
    10073037-002CLF
    Amphenol Communications Solutions Extended Height eSCA2 Fiber Channel Receptacle 40 Position, SMT, Lead-Free, without dustcover, with pickup cap PDF
    DRV201YFMR
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-DSLGA -40 to 85 Visit Texas Instruments Buy
    DRV201AYMBR
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-PICOSTAR -40 to 85 Visit Texas Instruments Buy
    DRV201YFMT
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-DSLGA -40 to 85 Visit Texas Instruments

    Documents mentioning PICKUP COIL E

    Document Partial File Text Tags Type PDF
    aichi
    Aichi Micro Intelligent 1-D MI Sensor circuit board 1. Pin assignment Pickup coil input Feedback coil input VDD (+5v) MI chip (1-D type) OUTPUT Sensor GND Feedback coil GND GND Pickup coil GND Sensor input Synchronous Signal Adjustment (Don’t touch)
    Original PDF
    l484
    L484 MAGNETIC PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL DARLINGTON OPERATES WITH A WIDE RANGE OF MAGNETIC PICKUP TYPES CHARGING ANGLE (DWELL) CONTROL COIL CURRENT PEAK LIMITATION CONTINUOUS COIL CURRENT PROTECTION TACHOMETER SIGNAL OUTPUT
    Original PDF
    l484
    L484 MAGNETIC PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL DARLINGTON OPERATES WITH A WIDE RANGE OF MAGNETIC PICKUP TYPES CHARGING ANGLE (DWELL) CONTROL COIL CURRENT PEAK LIMITATION CONTINUOUS COIL CURRENT PROTECTION TACHOMETER SIGNAL OUTPUT
    Original PDF
    l484
    L484 ® MAGNETIC PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL DARLINGTON OPERATES WITH A WIDE RANGE OF MAGNETIC PICKUP TYPES CHARGING ANGLE (DWELL) CONTROL COIL CURRENT PEAK LIMITATION CONTINUOUS COIL CURRENT PROTECTION TACHOMETER SIGNAL OUTPUT
    Original PDF
    l484
    L484 ® MAGNETIC PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL DARLINGTON OPERATES WITH A WIDE RANGE OF MAGNETIC PICKUP TYPES CHARGING ANGLE (DWELL) CONTROL COIL CURRENT PEAK LIMITATION CONTINUOUS COIL CURRENT PROTECTION TACHOMETER SIGNAL OUTPUT
    Original PDF
    l482
    L482 HALL–EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (DWELL) CONTROL COIL CURRENT PEAK VALUE LIMITATION CONTINUOUS COIL CURRENT PROTECTION CONDUCTION AND DESATURATION TIME
    Original PDF
    l482
    L482 ® HALL–EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (DWELL) CONTROL COIL CURRENT PEAK VALUE LIMITATION CONTINUOUS COIL CURRENT PROTECTION CONDUCTION AND DESATURATION TIME
    Original PDF
    l482
    L482 ® HALL–EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (DWELL) CONTROL COIL CURRENT PEAK VALUE LIMITATION CONTINUOUS COIL CURRENT PROTECTION CONDUCTION AND DESATURATION TIME
    Original PDF
    l482
    SGS-THOMSON L482 ILO HALL-EFFECT PICKUP IGNITION CONTROLLER ■ DIRECT DRIVING OF THE EXTERNAL PO­ WER DARLINGTON . COIL CURRENT CHARGING ANGLE (DWELL) CONTROL . COIL CURRENT PEAK VALUE LIMITATION ■ CONTINUOUS COIL CURRENT PROTECTION ■ CONDUCTION AND DESATURATION TIME
    OCR Scan PDF
    l497
    L497 ® HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT
    Original PDF
    l497
    L497 HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT REACHED
    Original PDF
    l497
    L497 HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT REACHED
    Original PDF
    l497
    L497 ® HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT
    Original PDF
    l497
    L497 HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT REACHED
    Original PDF
    l497
    L497 HALL EFFECT PICKUP IGNITION CONTROLLER… DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON COIL CURRENT CHARGING ANGLE (dwell) CONTROL PROGRAMME COIL CURRENT PEAK LIMITATION PROGRAMMABLE DWELL RECOVERY TIME WHEN 94 % NOMINAL CURRENT NOT REACHED
    Original PDF
    l497
    rZ 7 SGS-THOMSON L497 y !O T © œ s HALL EFFECT PICKUP IGNITION CONTROLLER ■ DIRECT DRIVING OF THE EXTERNAL PO­ W ER DARLINGTON ■ COIL CURRENT CHARGING ANGLE (dwell) CONTROL ■ PROGRAMMABLE COIL CURRENT PEAK LIMITATION ■ PROGRAMMABLE DWELL RECOVERY TIME
    OCR Scan PDF
    az850
    AZ850 MICROMINIATURE POLARIZED RELAY FEATURES • Microminiature size: Height: .197 inches (5 mm); Length: .551 inches (14 mm); Width: .354 inches (9 mm) • High sensitivity, 79 mW pickup • Monostable and bistable (latching) single coil and two coil versions available
    Original PDF
    az850
    AZ850 MICROMINIATURE POLARIZED RELAY FEATURES • Microminiature size: Height: .197 inches (5 mm); Length: .551 inches (14 mm); Width: .354 inches (9 mm) • High sensitivity, 79 mW pickup • Monostable and bistable (latching) single coil and two coil versions available
    Original PDF
    az850
    AZ850 MICROMINIATURE POLARIZED RELAY FEATURES • Microminiature size: Height: .197 inches (5 mm); Length: .551 inches (14 mm); Width: .354 inches (9 mm) • High sensitivity, 79 mW pickup • Monostable and bistable (latching) single coil and two coil versions available
    Original PDF
    l497
    rZ 7 * 7# S G S -T H O M S O N R (UKgTTISMIKSS L497 HALL EFFECT PICKUP IGNITION CONTROLLER . DIRECT DRIVING OF THE EXTERNAL POWER DARLINGTON - COIL CURRENT CHARGING ANGLE (dwell) CONTROL ■ PROGRAMME COIL CURRENT PEAK LIMITA­ TION . PROGRAMMABLE DWELL RECOVERY TIME
    OCR Scan PDF