Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PICK UP COIL Search Results

    PICK UP COIL Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    95730-003
    Amphenol Communications Solutions BergStik® 2.54mm, Board To Board Connector, Pick up cap. PDF
    54202-F0810PLF
    Amphenol Communications Solutions CONNECTOR, BERGSTIK 0.10-SMT,D/R,PICK-UP CAPS PDF
    7712E0225S01LF
    Amphenol Communications Solutions Smart Card Reader, Input Output Connectors, Connectors for Vandalism Proof, 8 contacts, Durability Environment, Pick and Place Tray, Lead Free. PDF
    DRV201YFMR
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-DSLGA -40 to 85 Visit Texas Instruments Buy
    DRV201AYMBR
    Texas Instruments 100mA Voice Coil Motor Lens Driver with Ringing Compensation for Camera Autofocus 6-PICOSTAR -40 to 85 Visit Texas Instruments Buy

    Documents mentioning PICK UP COIL

    Document Partial File Text Tags Type PDF
    nn-301
    AC Relays HARTMAN Aerospace Power Products NN-301 SPDT with Time Delay on Pick-Up, 50 Amps, 115 VAC, 400 Hz Features: • SPDT Main Contacts • 115 VAC Coil • Time Delay on Pick-Up • 115 VAC, 400 Hz • 50 Amps • High Reliability • Meets many requirements of MIL-R-6106
    Original PDF
    ds2e
    TESTING HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES 9.9 .390 35.24 1.387 9.8 .386 9.9 .390 20 .787 DS4E 15 .590 DS-RELAYS 9.8 .386 9.9 .390 9.8 .386 DS2E DS1E mm inch • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available
    Original PDF
    DS HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING
    DS HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY 35.24 1.387 DS RELAYS FEATURES 9.9 .390 9.8 .386 9.9 .390 20 .787 9.8 .386 9.9 .390 15 .590 9.8 .386 DS4E DS2E mm inch DS1E • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available
    Original PDF
    ds2e
    TESTING HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES 9.9 .390 35.24 1.387 9.8 .386 9.9 .390 20 .787 DS4E 15 .590 DS-RELAYS 9.8 .386 9.9 .390 9.8 .386 DS2E DS1E mm inch • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available
    Original PDF
    ds4e
    TESTING HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES 9.9 .390 35.24 1.387 9.8 .386 9.9 .390 20 .787 DS4E 15 .590 DS-RELAYS 9.8 .386 9.9 .390 9.8 .386 DS2E DS1E mm inch • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available
    Original PDF
    DS HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING
    DS HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES 9.9 .390 35.24 1.387 9.8 .386 9.9 .390 20 .787 9.8 .386 DS4E 9.9 .390 15 .590 DS RELAYS 9.8 .386 DS2E DS1E mm inch • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available
    Original PDF
    DS HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING
    DS HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES 9.9 .390 35.24 1.387 9.8 .386 9.9 .390 20 .787 9.8 .386 15 .590 DS4E DS RELAYS 9.9 .390 9.8 .386 DS2E DS1E mm inch • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available
    Original PDF
    ds4e
    TESTING HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES 9.9 .390 35.24 1.387 9.8 .386 9.9 .390 20 .787 DS4E 15 .590 DS-RELAYS 9.8 .386 9.9 .390 9.8 .386 DS2E DS1E mm inch • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available
    Original PDF
    DS HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING
    DS HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY 35.24 1.387 DS RELAYS FEATURES 9.9 .390 9.9 .390 20 .787 9.8 .386 9.8 .386 9.9 .390 15 .590 9.8 .38 DS4E DS2E mm inch DS1E • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available
    Original PDF
    rxke 1
    A SEA Catalogue RK33-12 E Edition 1 1979-12 File R, Part 1 Time-lag relay type RXKE 1 with pick-up delay • Pick-up delay adjustable between 20 ms and 99 s For use in protective systems and automatic equipment Continuous or summation time measuring
    OCR Scan PDF
    lr26550
    HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY UL File No.: E43149 ''9.9 ^ ^ s r - i ^ D S - R * • DS1 S CSA File No.: LR26550 200 mW pick-up power 100 mW pick-up power types available Latching types available High switching capacity: 60 W, 125 VA
    OCR Scan PDF
    Bestar POWER RELAY FEATURES Miniature size (28*
    Bestar POWER RELAY FEATURES Miniature size (28* 21.5*35.5mm) High switching capacity up to 5A Conforming to UL stardard UL File No. E l 47052 ■■■ COIL RATING (at 20°C) Nominal Voltage Coil Resistance ( £2±10%) Pick-Up Voltage Drop-Out Voltage 6VDC
    OCR Scan PDF
    az832
    AZ832 160 PCB signal relays Polarized DIP relays - single side stable AZ832 polarized DIP relays - single side stable • Low profile for compact board spacing • DC coils: up to 48 V DC • High sensitivity, 96 mW pick up • Life expectancy to 20 million operations • High switching capacity, 60 W, 250 VA • Fits standard
    Original PDF
    bestar
    Bestar POWER RELAY ■ FEATURES • ^ M iniature size (28* 2 1 .5 * 3 5 .5m m ) High sw itching capacity up to 5A C o n fo rm ing to U L stardard U L File No. E147052 ■ COIL RATING (at 20°C) Nominal Voltage Coil Resistance ( fì±IO%) Pick-Up
    OCR Scan PDF
    schaltungen
    Frauenhofer Institut Mikroelektronische Schaltungen und Systeme Duisburg . Dresden . Münschen FGS1/COB_07 X-Y-Two-Axes Magnetic Field Sensor System Features Due to the changes of magnetic flux inside the core a voltage is induced in the pick-up coils. The second harmonic
    Original PDF
    analog switch
    Maxim > App Notes > BATTERY MANAGEMENT SWITCHES AND MULTIPLEXERS Keywords: analog switch, analogue switch, relay power dissapation, boost pull-in pick-up voltage, dropout voltage Feb 04, 2002 APPLICATION NOTE 956 Analog Switch Lowers Relay Power Consumption
    Original PDF
    Application Note Temperature Considerations for
    Application Note Temperature Considerations for DC Relays Relays and temperature are intertwined. When a relay is exposed to various temperatures, its operating characteristics change dependent upon the temperature. The most notable changes occur in the pick-up
    Original PDF
    RSB n Features • 2 Pole relay suitable for signal
    RSB n Features • 2 Pole relay suitable for signal circuits High sensitivity, polarized ( 100mW pick-up ) Gold clad silver nickel contacts Meets FCC Part 68 2 coil latching version available UL E1555UL E128155 CSA LR700170 n Specifications Contact Arrangement
    Original PDF
    shinmei
    http://www.shinmei-e.co.jp Using Permanent Magnet, High sensitivity Two Poles Signal Relay RSB RELAYS 1/4 [] Features <>2 pole relay suitable for signal circuit. <>High sensitive polarized relay. 100mW pick-up power. (200mW Electric power consumption) <>150mW Electric power consumption available.
    Original PDF
    shinmei
    http://www.shinmei-e.co.jp Using Permanent Magnet, High sensitivity Two Poles Signal Relay RSB RELAYS 1/4 [] Features <>2 pole relay suitable for signal circuit. <>High sensitive polarized relay. 100mW pick-up power. (200mW Electric power consumption) <>150mW Electric power consumption available.
    Original PDF
    JS-M JS-M RELAYS Automotive Ultra-Miniature Power
    JS-M JS-M RELAYS Automotive Ultra-Miniature Power Relay >Low pick-up voltage for high ambient use • Sealed construction >Ultra-miniature size with universal footprint • Usable at high temperature: 85°C 185 F mm inch SPECIFICATIONS Contact Characteristics
    OCR Scan PDF