PEPPERL FUCHS SJ Search Results
Documents mentioning PEPPERL FUCHS SJ
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| sj5-n | SJ5-N Inductive proximity switches Comfort series 5 mm slot width 5 2 15 10 5 1 6,9 3 10 15 Ø 1,7 www.pepperl-fuchs.com Effective internal inductivityLi Li NAMUR NC 5 mm 4… 6 mm 8V ≤ 1 mA mA 0… 2000 Hz -25… 100 °C (248… 373 K) EN 60947-5-2 |
Original | ||||
| catalog sensors for process applications | FACTORY AUTOMATION CATALOG SENSORS FOR PROCESS APPLICATIONS 1FQQFSM'VDIT°6OCFBUBCMFGPSRVBMJUZBOEDIPJDF 8F BSF B MFBEJOH NBOVGBDUVSFS PG JOEVTUSJBM TFOTPST BOE TFOTPS TZTUFNT NBLJOHVTTQFDJBMJTUTJOUIFTFGJFMETUIFSFGPSFQSPWJEJOHZPVXJUIBOFYUFO |
Original | ||||
| Transformer Isolated Barriers KFD2-SRA-Ex* | Transformer Isolated Barriers KFD2-SRA-Ex* Output: Relay Input EEx ia IIC Input II + - Control circuit EEx ia IIC 24 V DC nominal supply voltage Reversible mode of operation Lead monitoring (short circuit LK and interruption LB) with LED indicator (red flashing), switching output and |
Original | ||||
| sj10-n | 2-Draht NAMUR Schlitzförmig 5,5 25 40 55 Komfortreihe 10 mm Schlitzweite 44 32 10 Ø 18 8 12 45 Pg9 16 10 mm SJ10-N Schutzart Anschlussart Aderquerschnitt Gehäusematerial Daten für den Ex-Bereich EG-Baumusterprüfbescheinigung Zugeordneter Typ Kennzeichnung |
Original | ||||
| sj15-n | 2-Draht NAMUR Schlitzförmig Komfortreihe 15 mm Schlitzweite 30 18 60 42 15 5,8 48 15 mm SJ15-N Schutzart Anschlussart Aderquerschnitt Gehäusematerial Daten für den Ex-Bereich EG-Baumusterprüfbescheinigung Zugeordneter Typ Kennzeichnung Wirksame innere Kapazität Ci |
Original | ||||
| namur | 2-Draht NAMUR Schlitzförmig Komfortreihe 3,5 mm Schlitzweite 5 2 15 10 3,5 1 6,75 3 10 19,5 1,85 3,5 mm SJ3,5-N WEISS Schutzart Anschlussart Aderquerschnitt Gehäusematerial Daten für den Ex-Bereich EG-Baumusterprüfbescheinigung Zugeordneter Typ Kennzeichnung |
Original | ||||
| PlantPAx Process Automation System Selection | PlantPAx Process Automation System Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell |
Original | ||||
| Inductive Proximity Sensors Slot sensors are | Inductive Proximity Sensors Slot sensors are designed to meet IP67 ratings and are protected against shock, vibration, and contamination. We offer 3- and 4-wire DC models, 2-wire AC and NAMUR output style sensor. All are CE and UL listed. See our NAMUR product section for available slot sensors with |
Original | ||||
| brad harrison | B rad H a r r is o n C o n n e c t o r S y s t e m s Micro Change and Multi-Port Interconnect System Technical Data Sheet Woodhead / Brad Harrison Micro Change Portables MICRO CHANGE - 4 POLE 2, 3 & 4 WIRE - SINGLE KEY WAY Male Pins Fem ale C ontacts M12 Male Threads |
OCR Scan | ||||
| mt3809g | Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG December, 2014 Models MT3809G & MT3810G Brooks® Models MT3809G and MT3810G Metal Tube Variable Area Flowmeters Model MT3809G General Purpose Housing Model MT3809G Model MT3809G |
Original | ||||
| MTL5500 Series isolating interface units | MTL5500 Series isolating interface units Instruction Manual INM5500 ii INM5500-4 October 2013 Contents 1 INTRODUCTION… 1 2 DESCRIPTION… 1 |
Original | ||||
NEED IT NOW? BUY REMAN! SEE PAGE lxx xx xvi SOLUTIONS, SOLUTIONS… Q A r e q u a l i t y, c o s t , a n d t i m e i m p o r t a n t to you? A ELECTRICAL SOUTH! Q Do you spend too much of your valuable time dealing with too m a n y d i ff e r e n t r e p a i r v e n d o r s ? |
Original |