PELTIER POWER Search Results
PELTIER POWER Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| SF-SFP28LPB1W-0DB | Amphenol Cables on Demand | Amphenol SF-SFP28LPB1W-0DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 0dB Attenuation & 1W Power Consumption | |||
| SF-SFPPLOOPBK-0DB | Amphenol Cables on Demand | Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption | |||
| SF-SFP28LPB1W-3DB | Amphenol Cables on Demand | Amphenol SF-SFP28LPB1W-3DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 3dB Attenuation & 1W Power Consumption | |||
| SF-100GLB1.5W-6DB | Amphenol Cables on Demand | Amphenol SF-100GLB1.5W-6DB QSFP 100G Loopback Adapter Module for QSFP28 Port Testing - 6dB Attenuation & 1.5W Power Consumption [100-Gigabit Ethernet Ready] | |||
| SF-QSFPLOOPBK-003 | Amphenol Cables on Demand | Amphenol SF-QSFPLOOPBK-003 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 3dB Attenuation & 1.5W Power Consumption [Copper+Optical Ready] |
Documents mentioning PELTIER POWER
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| cpm-2f | rev. PART NUMBER: CPM-2F DESCRIPTION: peltier cooling unit CUI’s patented CPM-2 series cooling modules incorporate peltier technology in a convenient package that maximizes heat absorption and reduces overall assembly cost. The CPM-2 is assembled with our high performance peltier device between two precision-machined aluminum plates using thermally-conductive |
Original | ||||
| cw laser diode | HIGH POWER CW LASER DIODE with PELTIER-COOLING L8413 HIGH POWER CW LASER DIODE with PELTIER-COOLING L8413 Figure 1: Radiant Output Power vs. Forward Current (Typ.) RELATIVE RADIANT OUTPUT POWER (%) Top(c) = 20 °C 20 10 10 30 20 FORWARD CURRENT If (A) PRELIMINARY DATA |
Original | ||||
| HIGH POWER CW LASER DIODE with A Heatsink for | HIGH POWER CW LASER DIODE with A Heatsink for PELTIER-COOLING L8413 PRELIMINARY DATA Compact Peltier-cooling type FEATURES High optical power : 30 W/bar High stability Long life High cost performance Compact APPLICATIONS Pumping source for solid state lasers |
Original | ||||
| l8413 | HIGH POWER CW LASER DIODE with PELTIER-COOLING L8413 HIGH POWER CW LASER DIODE with PELTIER-COOLING L8413 Figure 1: Radiant Output Power vs. Forward Current (Typ.) Figure 2: Typical Emission Spectrum 100 RELATIVE RADIANT OUTPUT POWER (%) 30 Top=25℃ RADIANT OUTPUT POWER (W) |
Original | ||||
| peltier effect | Issued March 1999 232-3052 Data Pack F Data Sheet Peltier effect heat pumps RS stock numbers 618-724, 618-730 A range of semi-conductor thermoelectric devices working on the Peltier effect. When supplied with a suitable electric current they can either cool or heat. When |
Original | ||||
| power drivers | 19-2447; Rev 1; 5/04 KIT ATION EVALU E L B A AVAIL Power Drivers for Peltier TEC Modules The MAX1968/MAX1969 are highly integrated and costeffective, high-efficiency, switch-mode drivers for Peltier thermoelectric cooler (TEC) modules. Both devices utilize direct current control to eliminate current surges in |
Original | ||||
| max1968 | 19-2447; Rev 2; 2/07 KIT ATION EVALU E L B A IL AVA Power Drivers for Peltier TEC Modules The MAX1968/MAX1969 are highly integrated and costeffective, high-efficiency, switch-mode drivers for Peltier thermoelectric cooler (TEC) modules. Both devices utilize direct current control to eliminate current surges in |
Original | ||||
| max1968 | 19-2447; Rev 0; 4/02 KIT ATION EVALU E L B A AVAIL Power Drivers for Peltier TEC Modules The MAX1968/MAX1969 are highly integrated and costeffective, high-efficiency, switch-mode drivers for Peltier thermoelectric cooler (TEC) modules. Both devices utilize direct current control to eliminate current surges in |
Original | ||||
| 19-2447; Rev 2; 2/07 KIT ATION EVALU E L B A | 19-2447; Rev 2; 2/07 KIT ATION EVALU E L B A AVAIL Power Drivers for Peltier TEC Modules The MAX1968/MAX1969 are highly integrated and costeffective, high-efficiency, switch-mode drivers for Peltier thermoelectric cooler (TEC) modules. Both devices utilize direct current control to eliminate current surges in |
Original | ||||
| peltier | Issued March 1997 232-3052 Data Pack F Data Sheet Peltier effect heat pumps RS stock numbers 618-724, 618-730 A range of semi-conductor thermoelectric devices working on the Peltier effect. When supplied with a suitable electric current they can either cool or heat. When |
Original | ||||
| SIEMENS SFH 482201 GaAlAs-LASER DIODE (250 mW) | SIEMENS SFH 482201 GaAlAs-LASER DIODE (250 mW) Package Dimensions in mm 11.7 04 0 Laser M irror ! ::;z 3 c : 7.0 1. 2. 3 4 Peltier-C ooler + NTC NTC Lase rdiode C athode 5 6 7 8 Laserdiode A node M onitor Diode Anode M onitor Diode C athode Peltier-C ooler (-) |
OCR Scan | ||||
| SIEMENS SFH 482301 GaAlAs-Laser Diode 500 mW | SIEMENS SFH 482301 GaAlAs-Laser Diode 500 mW Package Dimensions in mm 1. 2. 3. 4. Peltier-Cooler (+) NTC NTC Laserdiode Cathode 5. 6. 7. 8. Laserdiode Anode Monitor Diode Anode Monitor Diode Cathode Peltier-Cooler (-) FE A T U R E S Maximum Ratings * Monochromatic, Coherent Radiation |
OCR Scan | ||||
| SFH 482201 SIEMENS G aA lA s-LA S ER DIODE (250 | SFH 482201 SIEMENS G aA lA s-LA S ER DIODE (250 mW) Package Dimensions in mm 1. 2. 3 4. Peltier-Cooler + NTC NTC Laserdiode Cathode 5 6 7 8 Laserdiode Anode Monitor Diode Anode Monitor Diode Cathode Peltier-Cooler (-) FEATURES Maximum Ratings * Quantum-W ell Structure Manufactured |
OCR Scan | ||||
| peltier effect | Issued November 1988 F9192 Peltier effect heat pumps Stock numbers 618-718, 618-724, 618-730 A range of semi-conductor thermoelectric devices working on the Peltier effect. When supplied with a suitable electric current they can either cool or heat. When subjected to an externally applied temperature |
Original | ||||
|
|
||||||
| peltier effect | Issued March 1997 232-3052 Data Pack F Data Sheet Peltier effect heat pumps RS stock numbers 618-718, 618-724, 618-730 A range of semi-conductor thermoelectric devices working on the Peltier effect. When supplied with a suitable electric current they can either cool or heat. When |
Original | ||||
| peltier effect | Issued November 1988 009-192 Data Pack F Data Sheet Peltier effect heat pumps RS stock numbers 618-718, 618-724, 618-730 A range of semi-conductor thermoelectric devices working on the Peltier effect. When supplied with a suitable electric current they can either cool or heat. When |
Original | ||||
| SIEMENS SFH 482201 G aA lA s-LA SE R DIO DE (250 | SIEMENS SFH 482201 G aA lA s-LA SE R DIO DE (250 mW) Package Dimensions in mm 1. 2. 3. 4. Peltier-Cooler + NTC NTC Laserdiode Cathode 5. 6. 7 8. Laserdiode Anode Monitor Diode Anode Monitor Diode Cathode Peltier-Cooler (-) FEATU RES Maximum Ratings • Quantum-Well Structure Manufactured |
OCR Scan | ||||
| peltier | PART NUMBER: CP Series page 1 of 8 date 01/2009 DESCRIPTION: application notes APPLICATION NOTES 1. PELTIER HISTORY Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today’s thermoelectric industry. Seebeck found that if you placed a temperature gradient across the junctions of two dissimilar conductors, |
Original | ||||
| compressors | B C A NEW! Peltier Modules 100mm CUI Peltier Modules provide a convenient and reliable cooling solution. Their compact size make them ideal for applications that are size or weight limited and in applications where heat sinks, compressors or fans wouldn’t be feasible. They can be operated in any orientation, do not require the use of chloroflurocarbons and have |
Original | ||||
| Maxim > App Notes > AUTOMOTIVE TEMPERATURE | Maxim > App Notes > AUTOMOTIVE TEMPERATURE SENSORS and THERMAL MANAGEMENT Keywords: PID, DWDM, SFF, SFP, Fiber Optic, Laser Module, Thermoelectric Cooler, Peltier, Seebech, Thermocouple, TEC, Temperature Control, Thermal Loop, Thermistor Aug 23, 2004 APPLICATION NOTE 3318 |
Original | ||||