Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    PATCH PANELS Search Results

    PATCH PANELS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MP-54RJ45UNNE-001
    Amphenol Cables on Demand Amphenol MP-54RJ45UNNE-001 Cat5e Non-Booted Patch Cable with RJ45 Connectors (350MHz) 1ft PDF
    MP-54RJ45UNNE-002
    Amphenol Cables on Demand Amphenol MP-54RJ45UNNE-002 Cat5e Non-Booted Patch Cable with RJ45 Connectors (350MHz) 2ft PDF
    MP-54RJ45DNNE-010
    Amphenol Cables on Demand Amphenol MP-54RJ45DNNE-010 Cat5e STP Double Shielded Patch Cable (Braid+Foil Screened) with RJ45 Connectors - 350MHz CAT5e Rated 10ft PDF
    MP-54RJ45SNNE-025
    Amphenol Cables on Demand Amphenol MP-54RJ45SNNE-025 Cat5e STP Shielded Patch Cable (Foil-Screened) with RJ45 Connectors - 350MHz CAT5e Rated 25ft PDF
    MP-5ERJ45UNNB-003
    Amphenol Cables on Demand Amphenol MP-5ERJ45UNNB-003 Cat5e UTP Patch Cable (350-MHz) with Snagless RJ45 Connectors - Blue 3ft PDF

    PATCH PANELS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: Modular Patch Panels & Verteiler Modular Patch Panels & Distributors 3 Modular Patch Panels und Verteiler M odular Patch Panels and Distributors Inhaltsübersicht Modular Patch Panels und Verteiler Product Survey Modular Patch Panels and Distributors 1. 19" Modular Patch Panels


    OCR Scan
    d-71144 PDF

    krone

    Abstract: krone connector cat 6 patch panel 24 port patch panel cat 6 6690 AS PATCH PANEL TELCO 50 patch panel cat 6 krone km8 patch panels
    Contextual Info: Patch Panels 33 CAT 6 CL 16 WAY PATCH PANEL 19” 1U Category 6 performance patch panel. Jacks are fitted. Integral cable management and reusable label holders. Supplied complete with fixings. PATCH PANELS CL CL 16 way shielded patch panel Description Pack Qty


    Original
    482mm175mm483mm101mm+9kronekrone connectorcat 6 patch panel 24 portpatch panel cat 66690 aspatch paneltelco 50patch panel cat 6 krone km8patch panels PDF

    CP647

    Abstract: CP235 CP635
    Contextual Info: C P Series Quick Patch Coaxial Patch Panels Features • Quick Connect • Auto Locking • Reduced Weight • Various P ort Arrangements • Positive Pre-removal Interlocks • Replaceable Contacts CP Series Patch Panels Quick Patch coaxial patch panels are a new and unique


    OCR Scan
    cp375_cp435cp445cp455+8cp475_cp635cp645cp655cp675cp637cp647cp235 PDF

    CP-435

    Abstract: cp647 CP345 CP255 patch panel CP375 CP635
    Contextual Info: CP Series Quick Patch Coaxial Patch Panels Features • • • • • • Quick Connect Auto Locking Reduced Weight Various Port Arrangements Positive Pre-removal Interlocks Replaceable Contacts CP Series Patch Panels Mounting Surface A RF contact C Quick Patch coaxial patch panels are a new and unique


    Original
    pane60cp-435cp647cp345+4cp255patch panelcp375cp635 PDF

    PPE2232-MVJ-BK

    Abstract: PPE1232-MVJ-BK PPE2232-MVJT-BK PPE1226-SVJT-BK PPE4632-MVJ-BK PPE1224-SVJ-BK PPI2232RS-MVJ-BK PPI2232RS-MVJT PPE2224-SVJT-BK PPI1232RS-MVJ
    Contextual Info: Pro Patch Video Patching Systems www.adc.com • Pro Patch™ Video Panels Introduction 45 Pro Patch™ PPI/PPV Series Video Panels 47 Pro Patch™ PPE Series Video Panels 50 Pro Patch™ Unloaded Video Panels 52 Component Patching System CAPS 54 Video Jacks


    Original
    ppe2232-mvj-bkppe1232-mvj-bkppe2232-mvjt-bkppe1226-svjt-bk+6ppe4632-mvj-bkppe1224-svj-bkppi2232rs-mvj-bkppi2232rs-mvjtppe2224-svjt-bkppi1232rs-mvj PDF

    Contextual Info: NetKey Category 6 Patch Cords D ATA S H E E T Category 6/Class E patch cords are constructed of UTP 24 AWG stranded copper cable and a modular plug at each end. Patch cords are used in all work area outlets and patch panels. Patch cords are wired to be


    Original
    t568at568btia/eia-568-cansi/tia-777+2nkds31--ww-engww-nkds10 PDF

    patch panels

    Abstract: panels
    Contextual Info: 4 Modular Patch Panels & Verteiler Modular Patch Panels & Distributors " 6. Z u b e h ö r M odular Patch Panels 4ccessor/es M o d u la r Patch Panel', Bestell-Nr. Abb. Anmerkung Order Nr, Fig. Remarks B06013A0010 A Kabelrangierbügel für 19" Patch Panels


    OCR Scan
    b06013a0010h02025aq116h02025a0117m04022aoooo+7h02025a0111h06000a0001h02025a0084h02025a0085r00040a0006patch panelspanels PDF

    panduit UL-1863

    Abstract: NK6PC5BUY NK688M
    Contextual Info: NetKey Category 6 Patch Cords D ATA S H E E T Category 6/Class E patch cords are constructed of UTP 24 AWG stranded copper cable and a modular plug at each end. Patch cords are used in all work area outlets and patch panels. Patch cords are wired to be


    Original
    t568at568bnk688mtia/eia-568-c+4nkds10ww-nkds10panduit ul-1863nk6pc5buy PDF

    mb 11801

    Abstract: TX5500 ISO 11801 acr CPA72BL PSFC5504LG-ED PSFL5504DG-ED D11801 acr 100
    Contextual Info: TX5e Shielded Patch Cord SPECIFICATION SHEET specifications Patch cords shall be constructed of shielded 26 AWG stranded copper cable and shielded high performance modular plugs at each end. Patch cords shall be used in all work area outlets and patch panels. Patch cords shall be offered in gray


    Original
    t568at568btx5500ncsp16+8ww-ncsp16mb 11801iso 11801 acrcpa72blpsfc5504lg-edpsfl5504dg-edd11801acr 100 PDF

    UTP6X20

    Abstract: UTP6X10 CJ6X88TG
    Contextual Info: TX6 10G IG ™ Patch Cords SPECIFICATION SHEET specifications Patch cords shall be constructed of TX6 ™ 10GIG ™ UTP solid copper cable and enhanced performance TX6 ™ PLUS modular plugs at each end. Patch cords shall be used in all work area outlets and patch panels. Patch cords shall be


    Original
    10gigt568at568butp6x10+6utp6x14utp6x2010phonecom/ncsp10ncsp10cj6x88tg PDF

    log TX6

    Abstract: CJ6X88TG UTP6X20 PUL6X04DG-UE 10G rj45 PUP6X04BU-U PSANEXT UTP6X10
    Contextual Info: TX6 10G IG ™ Patch Cords SPECIFICATION SHEET specifications Patch cords shall be constructed of TX6 ™ 10GIG ™ UTP solid copper cable and enhanced performance TX6 ™ PLUS modular plugs at each end. Patch cords shall be used in all work area outlets and patch panels. Patch cords shall be


    Original
    10gigt568at568butp6x10+9utp6x14utp6x20sa-ncsp10log tx6cj6x88tgpul6x04dg-ue10g rj45pup6x04bu-upsanext PDF

    Contextual Info: NetKey Category 5e Patch Cords D ATA S H E E T Category 5e/Class D patch cords are constructed of UTP 24 AWG stranded copper cable and a modular plug at each end. Patch cords are used in all work area outlets and patch panels. Patch cords are wired to be


    Original
    t568at568btia/eia-568-cansi/tia-968-a+2nkds33--ww-engww-nkds06 PDF

    NK6PPG24Y

    Abstract: NK6PC5BUY
    Contextual Info: NetKey Category 6 Patch Cords DATA SHEET Category 6/Class E patch cords are constructed of UTP 24 AWG stranded copper cable and a modular plug at each end. Patch cords are used in all work area outlets and patch panels. Patch cords are wired to be compatible with both T568A and T568B


    Original
    t568at568bnk688mtia/eia-568-c+4nkds10ww-nkds10nk6ppg24ynk6pc5buy PDF

    6653 2 102-48

    Contextual Info: TrueNet Plug-and-Play Patch Panels As a part of the TrueNet® end-to-end solution, plug-and-play patch panels offer maximum versatility for any installation. These TrueNet panels come in three different versions, the Patch Plus panel, High-density Plug-and-Play panel, and the Mini patch panel. These blank patch panels


    Original
    19-inch104221ae6653 2 102-48 PDF

    PJ979

    Abstract: diode PJ979 diode pj88 diode pj76 PJ74 DIODE pj88 PJ84 PJ83 diode pj86 PJ76
    Contextual Info: Copper Communications Components Patch Cords – Bantam Two and Three Conductor Bantam Patch Cords Bantam patch cords are plastic jacketed, shielded cords with moldedon plugs. The plugs are made with molded insulation between conductors. Bantam patch cords are


    Original
    pj979diode pj979diode pj88diode pj76+6pj74 diodepj88pj84pj83diode pj86pj76 PDF

    Contextual Info: Enhanced IBM-Type Cabling System Patch Cords / Cable Assemblies Patch Cords. The enhanced patch cord has an Enhanced Data Connector on each end and utilizes the new Type 6A cable. These cords can be used to make moves and changes at the distribution patch panel,


    Original
    037-2551-4e037-2a037-6000-16-p037-6000-64-p PDF

    Contextual Info: LC to LC Patch cord, 1 fibre, tight-buffered cable, LSZH, 2.0 mm legs Single-mode OS2 XB , 15 m 143 Patch cables are used for non-permanent connections between patch panels, transmission equipment, etc. Pre-assembled cables allow for the implementation of


    Original
    tia/eia-604020201h2z31015m PDF

    Contextual Info: DP5e Punchdown Patch Panels SPECIFICATION SHEET specifications Category 5e/Class D, punchdown patch panels shall terminate 4-pair, 22 – 26 AWG, 100 ohm unshielded twisted pair cable with an industry standard single wire 110 punchdown tool. Patch panels shall include


    Original
    t568at568btx550024-port+5dpa245e88tgy48-portdpa485e88tgy12-portdp125e88tgy PDF

    Contextual Info: LC to LC Patch cord, 1 fibre, tight-buffered cable, LSZH, 2.0 mm legs Single-mode OS2 XB , 8 m 143 Patch cables are used for non-permanent connections between patch panels, transmission equipment, etc. Pre-assembled cables allow for the implementation of


    Original
    tia/eia-604020201h2z31008m PDF

    Contextual Info: Table of Contents Modular Plugs Patch Panels - PCB Category 5 Products Module & PCB Type Patch Cords RJ45 Jacks- Module Splitter & Couplers Pages 6-7 Surface Mount Box - PCB Blank Patch Panels Blank SMB - Module ya Multi-Port Outlet System, Module and PCB Type


    OCR Scan
    jo-13 PDF

    J02020

    Contextual Info: Jr Modular Patch Panels & Verteiler Modular Patch Panels & Distributors 1 19" M odular Patch Panels 19" M o d u la i Patch Parieis Leistungsmerkmale: • Geeignet für Datenübertragungen in High-Speed LANs mit Übertragungsraten > 100 Mbit/s. • EMV-Zertifikate nach EN 50081-2 und 50082-2 für den Industriebereich für die geschirmten Ausführungen.


    OCR Scan
    j02021a0013j02021a0014j02020a0011jo2o2oa0o12+3l00040a0009d-71144j02020 PDF

    UTP6X20

    Contextual Info: DP6 10G IG ™ Patch Panels SPECIFICATION SHEET specifications Patch panels shall mount to standard EIA 19" or 23" racks. Industry standard single wire 110 punchdown tools shall be used for terminations. Patch panels shall be supplied with T568A and T568B wiring configurations.


    Original
    t568at568b10gigdp246x88tg+4dp486x88tgdpa246x88tgdpa486x88tgutp6x20 PDF

    Contextual Info: SC to SC Patch cord, 1 fibre, tight-buffered cable, LSZH, 2.8 mm legs Single-mode OS2 , 10 m 143 Patch cables are used for non­-permanent connections between patch panels, transmission equipment, etc. Pre­-assembled cables allow for the implementation of


    Original
    tia/eia-60400800-corning1585801r3z31010m PDF

    Contextual Info: SC to SC Patch cord, 1 fibre, tight-buffered cable, LSZH, 2.8 mm legs Single-mode OS2 , 2 m 143 Patch cables are used for non­-permanent connections between patch panels, transmission equipment, etc. Pre­-assembled cables allow for the implementation of


    Original
    tia/eia-60400800-corning1585801r3z31002m PDF