OUTSIDE SENSOR SIEMENS Search Results
OUTSIDE SENSOR SIEMENS Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| G842C051T3EU | Amphenol Communications Solutions | G842H Series, 1.0mm Pitch, Cable Side Terminal, Matte Tin, AWG#28-AWG#32, OD-0.8mm | |||
| U10KH7426001T | Amphenol Communications Solutions | SlimSAS Vertical X12 30u\\ Gold plating, Latch pin outside, Latch pin length=4.2mm, 24G, T&R packing | |||
| U10BH7424001T | Amphenol Communications Solutions | SlimSAS Vertical X8 30u\\ Gold plating, Latch pin outside, Latch pin length=2.2mm, 12G, T&R packing |
Documents mentioning OUTSIDE SENSOR SIEMENS
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| temperature sensors | 1 813 Passive sensor Active sensor Outside temperature sensors QAC100 QAC160 QAC170 Use The sensors are used for acquiring the outside air temperature. They are designed for use in connection with automation equipment, display and logging devices. Type summary |
Original | ||||
| fw-t1g | 1 Outdoor sensor 819 FW-T1G for heating, ventilation and air conditioning systems Outdoor sensor for heating, ventilation and air conditioning systems – T1 measuring element – Attractive, stylish design – Easy to mount, firm connection Use The FW-T1G outdoor sensor is suitable for the measurement of the outside temperature |
Original | ||||
| s Synco™ 700 Switching and monitoring device | s Synco™ 700 Switching and monitoring device RMS705B incl. extension modules RMZ785, RMZ787und RMZ788 Basic documentation CE1P3124en 01.04.2010 Building Technologies Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 |
Original | ||||
| 1811p01 | 1 1811P01 811 QAC… Outside Sensors Passive sensors for acquiring the outside temperature and – to a lesser degree – solar radiation, the wind effect and the temperature of the wall. Use The QAC… outside sensors are for use in heating, ventilation and air conditioning |
Original | ||||
| hkz 121 | SIEMENS Hall-Effect Vane Switch HKZ 121 Features Bipolar IC • Contactless switch with open collector output (40 mA) • Static switching • High switching frequency • Hermetically sealed with plastic • Unaffected by dirt, light, vibration • Large temperature and voltage range |
OCR Scan | ||||
| solar sensor | 942 1 FS-T1 Solar Sensor The sensor measures the influence of solar irradiation on the heating of internal rooms. The sensor allows the flow temperature or the supply air temperature to be optimised for different sides of the building in order to reduce energy use and to |
Original | ||||
| SIEMENS Typenbeschreibung Type Description 3 | SIEMENS Typenbeschreibung Type Description 3 Typenbeschreibung 3 Type Description 3.1 Niederdruckbereich (50 mbar bis 100 mbar) 3.1 Low Pressure Range (50 mbar to 100 mbar) Unterhalb von 200 mbar lassen sich mit kreisförmigen Membranen nur noch Aus gangssignale von höchstens 5 mV/V er |
OCR Scan | ||||
| SFH 900 SERIES SFH 905 SERIES SIEMENS MINIATURE | SFH 900 SERIES SFH 905 SERIES SIEMENS MINIATURE LIGHT REFLECTION EMITTER/SENSOR Package Dimensions in Inches (mm) Plastic Flash (Betwaen Leads) Sensor Surface .177 (4.5) .189(4.8)' .256(6.5) .276(7.0) .012(0.3) .020 (0.5) .059(1.5) .071 (1.8) FEATURES 524(13.3) —I |
OCR Scan | ||||
| qam22 | 1 Mounting flange 1771P02 1771P034 1771P01 771 QAM22 QAM22.2, QAM22.6 Duct Temperature Sensors QAM22… Serie B Sensors für acquiring the temperature in air ducts. Use The QAM22… duct temperature sensor is for use in ventilation and air conditioning plants for the following purposes: |
Original | ||||
| SFH 900 SERIES SIEMENS Miniature Light Reflection | SFH 900 SERIES SIEMENS Miniature Light Reflection Emitter/Sensor Dimensions in inches (mm) Plastic Flash (Between Lead s) S e nso r Surface .177 (4.5) .169 (4.8) 256 (6.5) .276 (7.0) L .012 (0.3) - H H .020 (0.5) '' .059 (1.5) .071 (1.8) FEATURES • Designed for short distances up to 5 mm |
OCR Scan | ||||
| mini profet family | APPLICATIONS POWER SEMICONDUCTORS Klaus Reinmuth ● Holger Heil Mini PROFET family: Rugged high-side switches with extremely low quiescent current Although designed as general-purpose switches, Siemens Mini PROFETs with their quiescent current of less than 10 µA are ideal |
Original | ||||
| qfa66 | 1 1852P020 1852P010 852 QFA66 QFA66 with AQF21.1 QFA66 Room sensor for relative humidity and temperature • Operating voltage AC 24 V Autput signals DC 0…10 V for relative humidity and temperature Very high measuring accuracy throughout the entire measuring range |
Original | ||||
| 1pa5e00054075 | SITRANS TW Instruction Manual (de/en) 03/2004 Instruction Manual (de/en) Edition 03/2004 @1PA5E00054075@ 1P A5E00054075 sitrans tw Siemens AG Bereich Automation and Drives Geschaeftsgebiet Process Instrumentation and Analytics D-76181 Karlsruhe www.siemens.com/processinstrumentation |
Original | ||||
| SFH 900 SERIES SIEMENS Miniature Light Reflection | SFH 900 SERIES SIEMENS Miniature Light Reflection Emitter/Sensor Dimensions in inches (mm) Plastic Flash (Between Leads) .177 (4.5) .189 (4.8)' 256 (6.5) 276 (7.0) .012(0.3) .020 (0.5) .039 (1 0 ) Max .059(1.5) _2 .071(1.8) FEATURES • |
OCR Scan | ||||
|
|
||||||
| transducer | 5 Signal transducer (T1) for Ni1000 temperature sensor 142 AQA61.20 Signal transducer allowing the use of Ni1000 sensors for controllers with a T1 sensor input. Converts an Ni1000 sensor signal into a T1-type output signal Transducer supply from connected controller |
Original | ||||
| System Catalog 2014 The information in this | System Catalog 2014 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. |
Original | ||||
| pressure sensor | 1 920 Differential pressure sensor QBE63-DP… for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and negative pressures and pressure differentials in HVAC systems. |
Original | ||||
| th300 | 2 © Siemens AG 2013 Temperature Measurement 2/2 Product overview 2/124 2/7 2/11 2/18 2/25 2/31 2/38 2/45 2/57 2/62 2/70 Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system |
Original | ||||
| simirel | SIMIREL Temperaturüberwachungsrelais 3RS1040/1140 3RS1041/2041 3RS2040/2140 Temperature monitoring relay Relais thermostatique Relé de vigilancia/monitorización de temperatura Relè di sorveglianza temperaturas Relé de controle de temperatura TW114202 S |
Original | ||||
| SIEMENS SFH 900 SERIES SFH 905 SERIES MINIATURE | SIEMENS SFH 900 SERIES SFH 905 SERIES MINIATURE LIGHT REFLECTION EMITTER/SENSOR Package Dimensions in Inches (mm) Plastic Flash {Between Leads) .177 (4.5) .169 (4.8) 256 (6.5) ,276 (7.0) .012(0.3) .020 (0.5) .039 (1.0) Max .059 (1.5) .071 (1.8) FEATURES 5 24(13.3) |
OCR Scan | ||||
| IPMI Overview, Progress and Implementation Tom | IPMI Overview, Progress and Implementation Tom Tom Slaight Slaight Server Server Management Management Architect Architect Enterprise Server Group Group Enterprise Server Intel Intel Corporation Corporation John John Graf Graf Server Server Management Management Architect |
Original | ||||
| 2 © Siemens AG 2015 Temperature Measurement 2/2 | 2 © Siemens AG 2015 Temperature Measurement 2/2 2/7 2/11 2/18 2/25 2/31 2/38 2/45 Product overview Transmitters for mounting in sensor head SITRANS TH100 two-wire system (Pt100) SITRANS TH200 two-wire system universal SITRANS TH300 two-wire system universal, HART |
Original | ||||
| fep300 | Data Sheet DS/FEP300-EN Electromagnetic Flowmeter ProcessMaster FEP300 Intuitive operation - Softkey-based functionality - “Easy Set-up” function Non-contact buttons - Parameterization of the device without the need to open the housing Diagnostics for real-life situations |
Original | ||||
| fep500 | Data Sheet DS/FEP500-EN Electromagnetic Flowmeter ProcessMaster FEP500 Intuitive operation - Softkey-based functionality - “Easy Set-up” function Diagnostics for real-life situations - Status messages in accordance with NAMUR - Help texts in the display |
Original | ||||