Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ORIFICE FLOW METER Search Results

    ORIFICE FLOW METER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    GP-IE156327SS-002
    Amphenol Cables on Demand Amphenol GP-IE156327SS-002 Shielded GPIB Cable (IEEE-488 Cable) w/ Stackable GPIB Connectors (24-pin M/F) 2m PDF
    GP-IE156327SS-001
    Amphenol Cables on Demand Amphenol GP-IE156327SS-001 Shielded GPIB Cable (IEEE-488 Cable) w/ Stackable GPIB Connectors (24-pin M/F) 1m PDF
    GP-IE156327SS-003
    Amphenol Cables on Demand Amphenol GP-IE156327SS-003 Shielded GPIB Cable (IEEE-488 Cable) w/ Stackable GPIB Connectors (24-pin M/F) 3m PDF
    GP-IE156327SS-005
    Amphenol Cables on Demand Amphenol GP-IE156327SS-005 Shielded GPIB Cable (IEEE-488 Cable) w/ Stackable GPIB Connectors (24-pin M/F) 5m PDF
    GP-IE156327SS-006
    Amphenol Cables on Demand Amphenol GP-IE156327SS-006 Shielded GPIB Cable (IEEE-488 Cable) w/ Stackable GPIB Connectors (24-pin M/F) 6m PDF

    Documents mentioning ORIFICE FLOW METER

    Document Partial File Text Tags Type PDF
    LG Series Flow Measurement Throttle Devices
    LG Series Flow Measurement Throttle Devices Throttle orifice Injecting nozzle device Direct-reading throttle orifice flow meter Venturi tube throttling device Part one Summary Preface Throttle device is the most historic and most extensively used flow measurement instrument. It features itself
    Original PDF
    User Guide IM/OMM Issue 2 Compact Orifice Flow
    User Guide IM/OMM Issue 2 Compact Orifice Flow Meter OriMaster M ABB The Company EN ISO 9001:2000 We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental
    Original PDF
    orifice flow meter
    User Guide – Sizing & Selection Software IM/OM/SW Issue 1 Compact Orifice Flow Meter OriMaster ABB The Company EN ISO 9001:2000 We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental
    Original PDF
    Data Sheet DS/OM Issue 2 Compact Orifice Flow
    Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster „ Integrated DP Flow measurement system – combines primary element with DP Transmitter in a single flowmeter assembly „ One-piece flowmeter, pressure tested as an assembly – improved reliability with no leaks to trace and rectify
    Original PDF
    differential pressure
    Data Sheet SS/DP Differential Pressure Flow Elements Issue 4  Comprehensive range of DP primary elements – including orifice plates, carrier assemblies, metering runs, nozzles, Venturi tubes, Torbar averaging pitot tubes, Wedge meters and meters for subsea use
    Original PDF
    2101160-ag
    Data Sheet 2101160-AG INTRODUCTION Based on ABB Totalflow XSeries technology, the µFLO 6210/6213 (microFLO) is a little sibling to the XFC and XRC (eXtendable Flow Computer and eXtendable Remote Controller). The µFLO is an accurate and reliable single tube orifice gas
    Original PDF
    VARIABLE AREA FLOWMETERS Flow Reference Section
    VARIABLE AREA FLOWMETERS Flow Reference Section Retaining Ring End Cap Body Flow Indicator Dust Guard Scale Assembly Seal Bumper Flow End Fitting Spider Plate Metering Cone Figure 4: Piston-type Variable Area Flowmeter 1 3 5 Magnet/ Piston Assembly A. INLET PORT
    Original PDF
    CAT.EUS70-26 A -UK Direct Operated 3 Port
    CAT.EUS70-26 A -UK Direct Operated 3 Port Solenoid Valve For Water, Oil, Steam, Air Reduction of power consumption (DC specification) 4.5 W 8 W 7 W 11.5 W  10.5 W 6 W New VX 3 Series VX31/32 /33 Reduction of power consumption Improvement of corrosion
    Original PDF
    CAT.EUS70-23 A -UK Direct Operated 2 Port
    CAT.EUS70-23 A -UK Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air New Series VX21/22 /23 Reduction of power consumption (DC specification) 4.5 W 4. 8 WǞ 7 W 10. 0.5 W 11.5 1.5 W Ǟ 10.5 6 WǞ Low power consumption type: 0. W 0.8 (Held at 24 VDC)
    Original PDF
    6200e
    Data Sheet 2101162-AH XFC 6200EX Overview 6200 Series Products XFC 6200EX INTRODUCTION FEATURES Based on ABB Totalflow XSeries technology, the XFC 6200EX offers an explosion proof product for differential metering and automation systems. The XFC 6200EX is an accurate and
    Original PDF
    vxz22
    Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve For Air, Water, Oil Reduced power consumption (DC spec.) 7W VXZ23: 11.5 W → 10.5 W VXZ22: 8 W → New VX Z Series VXZ22/23 CAT.EUS70-31A-UK Solenoid valves for various fluids used in a wide variety of
    Original PDF
    Series VC Direct Operated 2 Port Solenoid Valve
    Series VC Direct Operated 2 Port Solenoid Valve for Steam Series VCS VX VN„ VQ VDW VC LV PA 4.5-51 Multipurpose Valve for Steam Direct Operated 2 Port Solenoid Valve for Steam Series VCS Improved durability (nearly twice the life of the previous series) The internal resistance of moving parts has been reduced
    Original PDF
    Notice of Intellectual Property Rights The OMEGA®
    Notice of Intellectual Property Rights The OMEGA® Handbook Series is based upon original intellectual property rights that were created and developed by OMEGA. These rights are protected under applicable copyright, trade dress, patent and trademark laws. The distinctive, composite appearance of these Handbooks is uniquely identified with
    Original PDF
    2-Colour Display Digital Flow Switch Flow rate
    2-Colour Display Digital Flow Switch Flow rate range: 10, 25, 50,100 l/min. Minimum unit setting: 0.01 l/min. Fluid (0.1 l/min when the flow rate range is 25, 50, 100 l/min.) Air, N2, Ar, CO2 Repeatability: ±1%F.S. or less Grease-free Flow adjustment valve is integrated.
    Original PDF
    2600t
    Operating instructions 2600T Series Pressure Transmitters Model 267C Model 269C Contents 1 1 Safety Page Safety… 2 General safety precautions and health protection… 2
    Original PDF
    Data Sheet 2101199-AD Measurement and Automation
    Data Sheet 2101199-AD Measurement and Automation Products XSERIES FLOW COMPUTERS (XFC) and XSERIES REMOTE CONTROLLERS (XRC) Integrated Packages Battery powered Solar Panel or other DC voltage charging system Communications equipment in enclosure CSA C/US Class I, Div 2, Grp CD,
    Original PDF
    water meter
    Issued March 1997 232-6130 Data Pack G Water meter classification Data Sheet Water meters are primarily classified by size. That is, the nominal diameter of the water meter is matched to the size of the pipe to which it is being connected. However, it should always be confirmed that the expected flow
    Original PDF
    2101113-ab
    Data Sheet 2101113-AB INTRODUCTION Based on ABB Totalflow XSeries technology, the XFC 6201EX offers an explosion proof product for linear metering and automation systems. XFC 6201EX Overview 6200 Series Products XFC 6201EX Optional • Twelve (12) I/O point daughter card
    Original PDF
    2.217 A N C I L L I A R Y V A LV E S S E R I E S
    2.217 A N C I L L I A R Y V A LV E S S E R I E S ASS S O F T S TA R T - U P V A LV E S E R I E S ASS W h e n t h e m a i n c o m p re s s e d a i r s u p p l y i s s w i t c h e d o ff overnight or longer the air throughout the system re d u c e s t o a t m o s p h e r i c p re s s u re .
    Original PDF
    267cs
    Data Sheet SS/267CS/269CS Series 2600T Pressure Transmitters Model 267CS/269CS Multivariable for mass flow, selectable maximum working pressure up to 41 MPa, 5945 psi ■ Base accuracy: ± 0.075 %/± 0.04 % ■ Span limits – 0.05 to 2000 kPa; 0.2 in H2O to 290 psi
    Original PDF
    269cs
    Data Sheet FieldIT SS/269CS_4 2600T Series Pressure Transmitters Model 269CS Multivariable for mass flow selectable maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.04% ■ Span limits – 0.05 to 2000kPa, 0.2inH2O to 290psi differential
    Original PDF
    267cs
    Data Sheet FieldIT SS/267CS_4 2600T Series Pressure Transmitters Model 267CS Multivariable for mass flow selectable maximum working pressure up to 41MPa, 5945psi ■ Base accuracy : ±0.075% ■ Span limits – 0.05 to 2000kPa, 0.2inH2O to 290psi differential
    Original PDF