OF GAS SE Search Results
OF GAS SE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| BQ27425YZFR-G2A | Texas Instruments | System-Side Impedance Track™ Fuel Gauge | Gas Gauge Battery 15-DSBGA -40 to 85 |
|
|
|
| BQ27621YZFR-G1A | Texas Instruments | System-Side Fuel Gauge with Dynamic Voltage Correlation, Battery Gas Gauge 9-DSBGA -40 to 85 |
|
|
|
| BQ27411DRZR-G1A | Texas Instruments | Pack-Side Impedance Track™ Fuel Gauge | Battery Gas Gauge 12-SON -40 to 85 |
|
|
|
| BQ27425YZFR-G2B | Texas Instruments | System-Side Impedance Track™ Fuel Gauge | Gas Gauge Battery 15-DSBGA -40 to 85 |
|
|
|
| BQ27411DRZT-G1C | Texas Instruments | Pack-Side Impedance Track™ Fuel Gauge | Battery Gas Gauge 12-SON -40 to 85 |
|
|
Documents mentioning OF GAS SE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ad81 | g GAS SENSORS : TYPE AD81 CO & NO2 GAS SENSOR DESCRIPTION: PROVISIONAL DATA DIMENSIONS: Gas sensor made of thick film element. FEATURES: • Two sensing element on one chip: for CO(gasoline exhaust gas) and NO2(diesel exhaust gas) • Low influence of ambient atmosphere |
Original | ||||
| ad81 | GAS SENSORS : TYPE AD81 CO & NO2 GAS SENSOR DESCRIPTION: PROVISIONAL DATA DIMENSIONS: Gas sensor made of thick film element. FEATURES: • Two sensing element on one chip: for CO(gasoline exhaust gas) and NO2(diesel exhaust gas) • Low influence of ambient atmosphere |
Original | ||||
| infrared gas analyzer | INFRARED GAS ANALYZER FOR STACK GAS DATA SHEET ZSU This analyzer consists of an infrared gas analyzer, a zirconia O2 sensor and a gas sampling device. It is used for simultaneous and continuous measurement of the NOX, SO2, CO, CO2 and O2 components in the flue gas of various boilers, garbage incinerators, etc. |
Original | ||||
| exhaust gas sensor | PRODUT NAME : EXHAUST GAS SENSOR MODEL No. : GSP-EX01 DETECTING GAS : Exhaust gas of autovehicle (NOx and H2 ,,CO, HC etc.) FEATURES Uses Simple electrical circuit High sensitivity to exhaust gas of autovehicle APPLICATIONS For automobile ventilation control |
Original | ||||
| flow meter | Model LLQ Roots Flow meter for Gas LLQ Roots flow meter for gas (hereafter for short called flow meter) is a kind of volumetric flow meter used to measure volume flow of gas continuously passing through the pipe. In consideration of high velocity of gas flow, roots rotor is made of |
Original | ||||
| tgs 2611 | FIGARO PRODUCT INFORMATION TGS 2611 - for the detection of Methane Features: Applications: * Low power consumption * High sensitivity to methane * Long life and low cost * Uses simple electrical circuit * Domestic gas alarms * Portable gas detectors * Gas leak detector for gas appliances |
Original | ||||
| propane gas | Data Sheet GSD600 Gas Leak Detector for Methane and Propane The Amprobe GSD600 is a fast responding gas leak detector for methane and propane gas. The meter emits a frequency tone when gas is detected. The frequency of the beep coincides with the concentration of the gas. The LEDs display |
Original | ||||
| tgs 2611 | FIGARO PRODUCT INFORMATION TGS 2611 - for the detection of Methane Features: Applications: * Low power consumption * High sensitivity to methane * Long life and low cost * Uses simple electrical circuit * Domestic gas alarms * Portable gas detectors * Gas leak detector for gas appliances |
Original | ||||
| gas sensor | Overview PerkinElmer has designed a new Natural Gas Alarm Sensor in response to OEMs’ needs for highly reliable solution for natural gas detection. The Natural Gas Alarm sensor, as part of the Gas Sensor family, uses nondispersive infrared radiation (NDIR) and |
Original | ||||
| tgs 2611 | FIGARO PRODUCT INFORMATION TGS 2611 - for the detection of Methane Features: Applications: * Low power consumption * High sensitivity to methane * Long life and low cost * Uses simple electrical circuit * Domestic gas alarms * Portable gas detectors * Gas leak detector for gas appliances |
Original | ||||
| zaf-3 | THERMAL CONDUCTIVITY GAS ANALYZER <THERMOMAT> DATA SHEET ZAF-3 Thermal conductivity gas analyzer is a gas analyzer which quantitatively measures gas concentration by utilizing a causal relationship that the temperature of a heated platinum wire changes with gas concentration. |
Original | ||||
| infrared gas analyzer | INFRARED GAS ANALYZER FOR STACK GAS DATA SHEET ZSP This instrument consists of an (or two) infrared gas analyzer(s), a zirconia O2 sensor and a sampling device. It is used for measuring the NOx, SO2, CO and O2 components in the flue gas of various boilers, garbage incinerators, furnaces, etc. |
Original | ||||
| gas sensor | If you search “gas sensor” on www.seeedstudio.com , you can find a lot of gas sensor. We know that the air component is diverse, and a certain gas sensor can detect one or more air components, so we designed a series of gas sensor. There are about 7 kind of gas sensor for sale. They have similar name, it’s likely to cause |
Original | ||||
| infrared gas analyzer | NDIR TYPE INFRARED GAS ANALYZER DATA SHEET ZRC6 This infrared gas analyzer measures the concentration of gas by utilizing the characteristic of gas (molecule consisting of different-kind atoms) that it absorbs the infrared ray of a specific wavelength. Stable and accurate measurement is ensured due to use |
Original | ||||
|
|
||||||
| Data Pack A Issued July 1998 302-1016 Portable | Data Pack A Issued July 1998 302-1016 Portable Gas Monitors Data Sheet What is Gas? Figure 1 The name gas comes from the word chaos which neatly summarises the main feature of the simplest state of matter. A gas is a swarm of particles moving randomly and chaotically; |
Original | ||||
| awm40000 | ISSUE 4 Installation Instructions for the AWM40000 Series Mass Gas-Flow Sensors PK 80005 GENERAL INFORMATION AWM40000 Series microbridge mass gas-flow sensors operate on the theory of heat transfer due to mass gas-flow across the surface of the sensing element. The sensing element consists of a resistor |
Original | ||||
| Overvoltage Protection Gas-filled surge arresters | Overvoltage Protection Gas-filled surge arresters Gas Arresters/Diodes Gas arresters consist of a ceramic or glass tube designed with a specific diameter and length depending on the operating voltage. The cylinder is sealed with an inert gas inside and electrode caps and connection wire on |
OCR Scan | ||||
| sl1411a | Gas Discharge Tubes Heavy Duty Delta Range RoHS SL1411A Series Two-terminal Gas Plasma Arrester Pb ® The Greentube™ SL1411A (Delta) Series Gas Plasma Arrester (improved gas discharge tube (GDT)) features is a highperformance transient voltage suppressor designed for heavyduty protection of telecom and industrial equipment. |
Original | ||||
| henan hanwei electronics | Henan Hanwei Electronics Co., Ltd www.hwsensor.com MQ-4 Semiconductor Sensor for Natural Gas Sensitive material of MQ-4 gas sensor is SnO2, which with lower conductivity in clean air. When the target combustible gas exist, The sensor’s conductivity is more higher along with the gas concentration |
Original | ||||
| gas sensors | GAS SENSORS : TYPE AD35 AUTOMOTIVE CABIN GAS SENSOR DESCRIPTION: PROVISIONAL DATA DIMENSIONS: Gas sensor made of thick film element. FEATURES: • Two sensing elements for low sensitivity to ambient atmosphere • Typical applications include air purifier in |
Original | ||||
| pgc2005 | General Specifications Process Gas Chromatographs PGC2005 Temperature Programmed GC Application Usage Specialty analysis for separation of wide boiling range compounds. The PGC2005 “Temperature Programmed” Gas Chromatograph uses component separation to analyze gas or liquid samples. The |
Original | ||||
| ad35 | g GAS SENSORS : TYPE AD35 AUTOMOTIVE CABIN GAS SENSOR DESCRIPTION: PROVISIONAL DATA DIMENSIONS: Gas sensor made of thick film element. FEATURES: • Two sensing elements for low sensitivity to ambient atmosphere • Typical applications include air purifier in |
Original | ||||
| pgc2000 | Process Gas Chromatographs PGC2000 Series – Utility Consumptions SUPPORT GAS QUALITY PROCESS GAS CHROMATOGRAPHS INSTRUMENT AIR Instrument air is used for the purge of the electronics housings, the oven heater and to operate the chromatography valves. Normally instrument air should be oil free with a dew point of -40oC. |
Original | ||||