Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    OF BLOWN FUSE INDI Search Results

    OF BLOWN FUSE INDI Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCKE800NA
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B Datasheet
    TCKE800NL
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B Datasheet
    TCKE805NA
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Datasheet
    TCKE805NL
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, Fixed Over Voltage Clamp, WSON10B Datasheet
    TCKE812NA
    Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, Fixed Over Voltage Clamp, WSON10B Datasheet

    Documents mentioning OF BLOWN FUSE INDI

    Document Partial File Text Tags Type PDF
    Screw Clamp 35 mm DIN-Rail Terminals Circuit
    Screw Clamp 35 mm DIN-Rail Terminals Circuit Protection Fuse and Feed Through KDKS 1 KDKS1 KDKS 1/PE com bi-foot Note for blown fuse indicator version: Note for blown fuse indicator version: In the event of a faulty fuse, the In the event of a faulty fuse, the
    OCR Scan PDF
    blown fuse indicator
    Product Data Sheet 6SM30AXI Replace “X” with 1, 2, 3 or 4 for number of poles Midget Enclosed Fuse Holder 30 Amps, 600 Volts AC/DC with Blown Fuse Indicator 80V min for blown fuse indicator Wire Range: #6 - #14 AWG Cu Recommended Torque: 17.7 lbf-in. (2.0 N·m)
    Original PDF
    blown fuse indicator
    Product Data Sheet 6SC30AXI Replace “X” with 1, 2, 3 or 4 for number of poles Class CC Enclosed Fuse Holder 30 Amps, 600 Volts AC/DC with Blown Fuse Indicator 80V min for blown fuse indicator Wire Range: #6 - #14 AWG Cu Recommended Torque: 17.7 lbf-in. (2.0 N·m)
    Original PDF
    accessories
    DIAZED AND NEOZED ACCESSORIES SCREW CAP The Screw Cap types offered fit the various fuse and Fuse Base sizes. They hold the fuses in place and connect the head of the fuse with the load side of the Fuse Holder. The colored blown fuse indicator on the head of the fuse is
    Original PDF
    ask 1 ld
    Circuit Protection Terminals ASK 1 LD ASK 1 W arning: • Install AP partition after last fuse terminal. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures and reduce costly
    OCR Scan PDF
    ask 1 ld
    Circuit Protection Terminals ASK 1 LD ASK 1 Warning: • Install AP partition after last fuse terminal. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures and reduce costly
    Original PDF
    KDKS 1 Circuit Protection Terminals KDKS 1 KDKS 1
    KDKS 1 Circuit Protection Terminals KDKS 1 KDKS 1 PE Combi-foot Warning: • Install AP partition after last or KDKS 1. • Disconnect power before replacing the fuse. . Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures
    OCR Scan PDF
    Circuit Protection Terminals KDKS 1 with power on
    Circuit Protection Terminals KDKS 1 with power on indication combi-foot Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures
    Original PDF
    blown fuse indicator
    Circuit Protection Terminals KDKS 1 with power on indication combi-foot Warning: • Install AP partition after last ASK 1 or KDKS 1. • Disconnect power before replacing the fuse. Fuse terminals are available with LED blown fuse indicators, which speed identification of fuse failures
    Original PDF
    1262-2012.qxp:QuarkCatalogTempNew 8/31/12 8:44 AM
    1262-2012.qxp:QuarkCatalogTempNew 8/31/12 8:44 AM Page 1262 14 TEST & MEASUREMENT Blown-Fuse Indicating Panel Mount Type for 3AG Fuses INTERCONNECT Fuses, Fuse Holders, Fuse Blocks and Fuse Clips Approvals: Recognized under the Components Program of Underwriters Laboratories and Certified by CSA. Specifications.
    Original PDF
    ask 1 ld
    Terminal Blocks with Components ASK 1 LD/EN Blown Fuse Indication Fuse cartridge 5 x 20 only 805081 n___ r*» TH Warning: In the event of a faulty fuse, the connected circuit has a maximum leakage current of 2mA Dimensions Terminal width (+0.2 assembly tolerance)
    OCR Scan PDF
    Class CC Enclosed Fuse Holders - 600 Volt
    Class CC Enclosed Fuse Holders - 600 Volt Specifications: Tested and Approved for 200,000 Amps Short Circuit Withstand Rating Touchsafe IEC Type Design (IP20) DIN Rail Mount (35mm - symmetrical) Blown Fuse Indication Available Red dual LED indicator - range of operating
    Original PDF
    Blocks and Holders Fuse Blocks, Holders and
    Blocks and Holders Fuse Blocks, Holders and Accessories Class J POWR-SAFE Holders Features/benefits • Meets “Dead Front” requirements. Mountable on 35mm DIN-Rail. Blown fuse identification (Indicating versions only). Easy installation and removal of fuses. No special fuse pullers or tools
    Original PDF
    Terminal Blocks with Components W SI6LD Blown
    Terminal Blocks with Components W SI6LD Blown Fuse Indication Fuse cartridge, 5 x 2 0 WSI 6/2 LD DISC Fuse cartridge, VUmx 1/4M 5x25 5x30 with LED indicator with LED indicator for DC or A C voltage Note: Note: In the event of a faulty fuse, the connected circuit has a max
    OCR Scan PDF
    AKZ 4/10 (switch) AKZ 4/TC TS 15 SAKR for 5 x 20
    AKZ 4/10 (switch) AKZ 4/TC TS 15 SAKR for 5 x 20 mm fuse with 2 sockets Fuse Terminals: Warning: In case of blown fuse, the connected circuit is energized. Disconnect power before replacing the fuse. TS 15 TS 15 0366560000 without marking ASK 1 1627010000
    Original PDF
    GFN 1-1/2” X 13/32” GFN midget indicating fuses
    GFN 1-1/2” X 13/32” GFN midget indicating fuses are available in 34 ratings from 1/10A through 30A. These time-delay fuses have built-in blown fuse indicators which pop out at the end of the fuse to visually indicate when the fuse has operated to open the
    Original PDF
    fuses
    General Purpose US US Fuses General Purpose Fuses Midget Fuses (10x38 US) Time Delay GFN GFN midget indicating fuses are available in 34 ratings from 1/10A through 30A. These timedelay fuses have built-in blown fuse indicators which pop out at the end of the fuse to visually
    Original PDF
    GFN 1-1/2” x 13/32” MIDGET FUSES GFN midget
    GFN 1-1/2” x 13/32” MIDGET FUSES GFN midget indicating fuses are available in ratings from 1/10A through 30A. These time-delay fuses have built-in blown fuse indicators which pop out at the end of the fuse to visually indicate when the fuse has operated to open the circuit. Indicators may
    Original PDF
    Fuseholders For 3AG Fuses Blown-Fuse Indicating
    Fuseholders For 3AG Fuses Blown-Fuse Indicating Panel Mount Type ® QPL ORDERING INFORMATION: APPROVALS: Recognized under the Components Program of Underwriters Laboratories and Certified by CSA. Catalog Number 344 000 344 400 Series Series SPECIFICATIONS:
    Original PDF
    Fuseholders For 3AG Fuses Blown-Fuse Indicating
    Fuseholders For 3AG Fuses Blown-Fuse Indicating Panel Mount Type ® QPL ORDERING INFORMATION: APPROVALS: Recognized under the Components Program of Underwriters Laboratories and Certified by CSA. Catalog Number 344 000 344 400 Series Series SPECIFICATIONS:
    Original PDF
    Datasheet W S I F u s e Te r m i n a l s w i t h
    Datasheet W S I F u s e Te r m i n a l s w i t h L o w Current Status Indication Weidmuller offers versions of the WSI fuse terminals with low current blown fuse indication (BFI). The BFI circuit is located in parallel with the fuse so that a current goes through the indicator only when the
    Original PDF