NEMIC-LAMBDA L Search Results
NEMIC-LAMBDA L Result Highlights (2)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| LM9044V/NOPB | Texas Instruments | Lambda Sensor Interface Amplifier 20-PLCC -40 to 125 |
|
|
|
| LM9044VX/NOPB | Texas Instruments | Lambda Sensor Interface Amplifier 20-PLCC -40 to 125 |
|
|
Documents mentioning NEMIC-LAMBDA L
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| dsr30 | USERS MANUAL FOR NEMIC-LAMBDA SWITCHING POWER SUPPLY DSR SERIES (DSR30, DSR50) NEMIC-LAMBDA K.K. DSR50(Input DC24V) 1. DSR30(Input DC24V) DSR30(Input DC48V) DSR50(Input DC48V) SPECIAL FEATURES DSR Series is the most reliable switching power supply which was specially |
OCR Scan | ||||
| nemic lambda | NEMIC LAMBDA FR Series Application Notes (apn tl) PR Series Application Notes 1 NEMIC LAMBDA PR Series Application Notes (apntl) PH Series Connection *Add the circuit so that CNT turns on when IOG and ENA signals are both LOW. External Components between the PR series and the PH |
OCR Scan | ||||
| nemic-lambda | NEMIC-LAMBDA Single Output EWS3000T SERIES OPERATION M ANUAL 1. PREPARATION BEFORE U SE----------------------------------------------------------------------------------• Make sure that connections with the input/output terminals are properly made as shown in this manual. |
OCR Scan | ||||
| I NEMIC LAMBDA PP/PPD Series PP/PPD Series | I NEMIC LAMBDA PP/PPD Series PP/PPD Series Application Notes l Application Notes p.2-9 Block Diagram p.9-11 M ounting M ethod p .12 NÈM1 C LAMBDA Z P 'P W & m e * Application Notes ■ Recommended Fuse Ratings Basic Connection 5VDC 12VDC 24VDC 48VDC 2A 1A |
OCR Scan | ||||
| rm30-48 | RM30-48 Specifications NEMIC-LAMBDA * : For delivery, contact to our sales office. C112-01-01 MODEL ITEMS Nominal Output Voltage Maximum Output Current Nominal Output Power Efficiency (Typ) (∗1) Input Voltage Range Input Current (Typ) (∗1) In-rush Current (Typ) |
Original | ||||
| nemic-lambda | NEMIC-LAMBDA LTD ZUP SERIES COMMUNICATION TEST SET UP using Hyper Terminal ( Windows ) software DWG No: IA549-04-03 Prepared Checked Approved TEST PROGRAM: ZUP COMMUNICATION VIA HYPERTERMINAL 1 Equipment: PC with HyperTerminal of Windows, ZUP Power Supply, |
Original | ||||
| RM50-48/TEL Specifications NEMIC-LAMBDA * : For | RM50-48/TEL Specifications NEMIC-LAMBDA * : For delivery, contact to our sales office. C111-01-01/TEL_A MODEL ITEMS Nominal Output Voltage Maximum Output Current Nominal Output Power Efficiency (Typ) (∗1) Input Voltage Range Input Current (Typ) (∗1) In-rush Current (Typ) |
Original | ||||
| nemic-lambda | EWS 100 Specifications NEMIC-LAMBDA A120-01-01C MODEL ITEMS Nominal Output Voltage Average Output Current Average Output Power Efficiency Input Voltage Range * *:For delivery, contact to our sales office. * * * * EWS100 EWS100 EWS100 EWS100 EWS100 EWS100 EWS100 EWS100 EWS100 |
Original | ||||
| File E194395 Project 98ME31667 August 19, 1999 | File E194395 Project 98ME31667 August 19, 1999 REPORT on LISTED - MEASURING, TESTING AND SIGNAL GENERATION EQUIPMENT (UL 3111-1, PICQ, PICQ7) Nemic-Lambda Ltd. 20101 Karmiel, Israel Copyright © 1999 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to |
OCR Scan | ||||
| rm100-48 | RM100-48 Specifications NEMIC-LAMBDA * : For delivery, contact to our sales office. C110-01-01 MODEL ITEMS Nominal Output Voltage Maximum Output Current Nominal Output Power Efficiency (Typ) (∗1) Input Voltage Range Input Current (Typ) (∗1) In-rush Current (Typ) |
Original | ||||
| NEMIC-LAMBDA INSTRUCTION MANUAL SWS 600 | NEMIC-LAMBDA INSTRUCTION MANUAL SWS 600 Instruction Manual_____ BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. WARNING and CAUTION |
OCR Scan | ||||
| ph150s280 | PH150S280 Specifications NEMIC-LAMBDA * PH150S PH150S ITEMS 280-3.3 280-5 1 Nominal Output Voltage V 3.3 5 2 Maximum Output Current A 30 30 3 Nominal Output Power W 99 150 72 82 4 Efficiency (Typ) (∗1) % 5 Input Voltage Range - 200 ~ 400VDC 280VDC input A |
Original | ||||
| nemic-lambda | 4 - 04.8 (Mounting holes) m i i i i j_L -H to r rX i i i i LLJ c (1 1 .8 ) (13.8) (23.8) 35+1 r (unit : mm) M X B -1230-33 &NEMIC-LAMBDA MODEL NAME 18MAX 1 15±1 18MAX G021 —0 2 —04A |
OCR Scan | ||||
| kwd10-1212 | KWD10 Specifications NEMIC-LAMBDA *: For delivery, contact to our sales office. PA774-01-01 KWD10-1212 MODEL ITEMS CH1 KWD10-1515 CH2 -12V CH2 1 Nominal Output Voltage V +12V 2 Minimum Output Current A 3 Maximum Output Current A 0.45 0.45 0.36 0.36 4 Maximum Output Power |
Original | ||||
|
|
||||||
| kwd15 | KWD15 Specifications NEMIC-LAMBDA *: For delivery, contact to our sales office. PA775-01-01 KWD15-1212 MODEL ITEMS CH1 KWD15-1515 CH2 -12V CH2 1 Nominal Output Voltage V +12V 2 Minimum Output Current A 3 Maximum Output Current A 0.65 0.65 0.52 0.52 4 Maximum Output Power |
Original | ||||
| NEMIC-LAMBDA ZWS 5 SPECIFICATIONS A152-01-01C 13 | NEMIC-LAMBDA ZWS 5 SPECIFICATIONS A152-01-01C 13 14 15 16 17 18 19 20 21 22 23 24 25 26 MODEL ITEMS Nominal Output Voltage Minimum Output Current Maximum Output Current Maximum Peak Output Current Maximum Output Power Maximum Peak Output Power Efficiency (Typ) |
Original | ||||
| pf1000a-360 | PF1000A-360 Specifications NEMIC-LAMBDA * : For delivery, contact to our sales office. C109-01-01A PF1000A-360 V A W % Hz A A % V V V °C V mA - 360VDC 360VDC 100 ~ 240VAC 200 ~ 240VAC 85 ~ 265VAC 170 ~ 265VAC 85 ~ 255VAC 170 ~ 255VAC 2.8 4.2 1008 1512 90 |
Original | ||||
| pa766-01-01a | KWS5 Specifications NEMIC-LAMBDA *: For delivery, contact to our sales office. PA766-01-01A MODEL KWS5-5 KWS5-12 KWS5-15 15 ITEMS 1 Nominal Output Voltage V 5 12 2 Minimum Output Current A 3 Maximum Output Current A 1.0 0.45 0.35 4 Maximum Output Power W 5.0 |
Original | ||||
| pa758 | KS10 Specifications NEMIC-LAMBDA *: For delivery, contact to our sales office. PA758-01-01A MODEL KS10-5 KS10-12 12 ITEMS 1 Nominal Output Voltage V 5 2 Minimum Output Current A 3 Maximum Output Current A 2.0 0.9 4 Maximum Output Power W 10.0 10.8 5 Efficiency (typ) |
Original | ||||
| kws15-5 | KWS15 Specifications NEMIC-LAMBDA *: For delivery, contact to our sales office. PA768-01-01A MODEL KWS15-5 KWS15-12 KWS15-15 ITEMS 1 Nominal Output Voltage V 5 12 15 2 Minimum Output Current A 3 Maximum Output Current A 3.0 1.3 1 4 Maximum Output Power W 15.0 |
Original | ||||
| kwd5-1212 | KWD5 Specifications NEMIC-LAMBDA *: For delivery, contact to our sales office. PA773-01-01 KWD5-1212 MODEL ITEMS CH1 KWD5-1515 CH2 -12V CH2 1 Nominal Output Voltage V +12V 2 Minimum Output Current A 3 Maximum Output Current A 0.22 0.22 0.18 0.18 4 Maximum Output Power |
Original | ||||
| nemic-lambda | LWT 30H OUTPUT DERATING NEMIC-LAMBDA TOTAL OUTPUT POWER (W) Ta (°C) MOUNTING : A MOUNTING : B MOUNTING : C MOUNTING : D 0 ~ 20 30 40 50 60 30 30 30 24 18 30 30 30 24 18 30 30 15 - 30 30 15 - Total Output Wattage (W) OUTPUT DERATING CURVE Convection Cooling |
Original | ||||
| pa508-01-01 | PP10-5 Specifications NEMIC-LAMBDA PA508-01-01 " MODEL ITEMS PP 10-5-5 PP10-5-12 PP10-5-15 5 ------ ------ 1 Nominal Output Voltage 2 Maximum Output Current 3 Nominal Output Power V A 1.6 12 0.7 15 0.6 W 8.0 8.4 9.0 % 72 72 72 2.33 2.50 4 Efficiency (Typ) |
OCR Scan | ||||
| NEMIC-LAMBDA ZWS 10 SPECIFICATIONS A153-01-01C 13 | NEMIC-LAMBDA ZWS 10 SPECIFICATIONS A153-01-01C 13 14 15 16 17 18 19 20 21 22 23 24 25 26 MODEL ITEMS Nominal Output Voltage V Minimum Output Current A Maximum Output Current A Maximum Peak Output Current (*1) A Maximum Output Power W Maximum Peak Output Power |
Original | ||||
| nemic-lambda | EWS 150 Specifications NEMIC-LAMBDA A121-01-01C * MODEL *:For delivery, contact to our sales office. * * * * EWS150 EWS150 EWS150 EWS150 EWS150 EWS150 EWS150 EWS150 EWS150 -5 -6 -9 -12 -15 -18 -24 -28 V 5 6 9 12 15 18 24 28 A 30.0 25.0 16.7 12.5 10.0 8.4 6.3 |
Original | ||||