NDIR GAS SENSOR Search Results
NDIR GAS SENSOR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| COMBOSENSOR | Texas Instruments | XTR117 XTR117 4-20mA Current Loop Transmitter |
|
||
| COMBOBODYSENSOR | Texas Instruments | ADS1292 Complete Low Power Integrated Analog Front End for ECG Applications |
|
||
| V62/20606-01EX | Texas Instruments | Enhanced product, low-power, analog temperature sensor |
|
|
Documents mentioning NDIR GAS SENSOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ndir gas sensor | Visible/IR Lamps for NDIR Gas Sensors Gilway offers a line of Visible/IR lamps for use in applications such as nondispersive infrared gas sensors, analyzers, and monitors. Nondispersive Infrared (NDIR) sensors are simple spectroscopic devices often used for gas analysis. |
Original | ||||
| MICROPROCESSOR BASED NDIR GAS ANALYZER DATA SHEET | MICROPROCESSOR BASED NDIR GAS ANALYZER DATA SHEET ZRF This NDIR gas analyzer features a high accuracy, multiple functions and easy operation through use of a microprocessor. It also utilizes a mass flow detector noted for its high sensitivity and reliability. Being housed in a 19 inch rack case suitable |
Original | ||||
| gas sensor | Overview PerkinElmer has designed a new Natural Gas Alarm Sensor in response to OEMs’ needs for highly reliable solution for natural gas detection. The Natural Gas Alarm sensor, as part of the Gas Sensor family, uses nondispersive infrared radiation (NDIR) and |
Original | ||||
| gas analyzer | NDIR TYPE INFRARED GAS ANALYZER DATA SHEET ZRH This NDIR gas analyzer is used for measuring CO2, CO, SO2 and CH4 and features a high accuracy, multiple functions and easy operation through use of a microprocessor. It is housed in a 19 inch rack case suitable for mounting on a panel |
Original | ||||
| infrared gas analyzer | NDIR TYPE INFRARED GAS ANALYZER (5-COMPONENT ANALYZER) DATA SHEET This gas analyzer (ZKJ) is capable of measuring the concentrations of NO, SO 2, CO 2, CO, CH4 and O2 components in sample gas. NO, SO2, CO2, CO and CH4 are measured by non-dispersion infrared method (NDIR), while O 2 is measured by built-in |
Original | ||||
| infrared gas analyzer | NDIR TYPE INFRARED GAS ANALYZER DATA SHEET ZRG This NDIR gas analyzer features high accuracy, multiple functions and easy operation through use of a microprocessor. It also utilizes a mass flow detector noted for its high sensitivity and reliability. This analyzer is used not only for measuring environmental pollution but is also used for various processes and/or |
Original | ||||
| infrared gas analyzer | NDIR TYPE INFRARED GAS ANALYZER DATA SHEET ZRC6 This infrared gas analyzer measures the concentration of gas by utilizing the characteristic of gas (molecule consisting of different-kind atoms) that it absorbs the infrared ray of a specific wavelength. Stable and accurate measurement is ensured due to use |
Original | ||||
| tps 2534 | Lighting | Imaging | Telecom p Thermopile Infrared Detectors Dual Channel Thermopile TPS 2534 Thermistor temperature reference included Applications: infrared absorption (NDIR) gas sensing with reference channel The dual thermopile sensor TPS 2534 employs two single thermopile chips |
Original | ||||
| INFRARED GAS ANALYZER DATA SHEET ZRJ This gas | INFRARED GAS ANALYZER DATA SHEET ZRJ This gas analyzer (ZRJ) is capable of measuring the concentrations of CO2, CO, CH4,SO2 and O2 components in sample gas. CO2, CO, CH4 and SO2 are measured by non-dispersion infrared method (NDIR), while O2 is measured by paramagnetic or zirconia method. A maximum of 4 components including O2 (max. 3 components except for O2 measurement) |
Original | ||||
| ir1011 | [IR1011] IR1011 Photovoltaic Infrared Sensor GENERAL DESCRIPTION IR1011 is the world smallest mid-infrared quantum photo diode, made of InSb. This surface mount type sensor can be operated at room temperature, and applicable to human body detection, non-contacting temperature measurement, and NDIR gas sensor. |
Original | ||||
| ndir | Advance Cemas-NDIR Multi component Measuring System for Emission Monitoring and Process Control Specification Sheet 10/23 8.20 EN July 2002 n Complete analyzer system with gas sampling, sample conditioning, analyzer and system control unit in a single cabinet |
Original | ||||
| ir33b | IR3xxx Series, IR4xxx Series Miniature Infrared Gas Sensors for Non-Hazardous Areas FEATURES * * * * * * * * * * * * * * * * * * * Configured for carbon dioxide (IR31BC, IR41BC), hydrocarbons (IR32BC, IR33BC, IR42BC, IR43BC) or acetylene (IR34BC, IR44BC) Sensing ranges: 0 – 2% vol. (optional 0 – 5% vol.) for CO2, |
Original | ||||
| IR15TT, IR15TT-M, IR25TT, IR25TT-M Miniature | IR15TT, IR15TT-M, IR25TT, IR25TT-M Miniature Infrared Twin-Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining FEATURES * * * * * * * * * * * * * * * * * * * * * * * * * Two active gas channels for simultaneous detection of carbon dioxide, methane and hydrocarbons |
Original | ||||
| ir10100 | — Mixed Signal & Sensor Solutions IR 10100 PRODUCT BRIEF InSb Mid-Infrared Sensor Description The IR10100 is the smallest photovoltaic midinfrared sensor, based on an evolutionary InSb p-i-n structure. It detects wavelength from 2 to 7|jm at room tem perature, suitable for human body |
OCR Scan | ||||
|
|
||||||
| zke24 | Fuji Instrumentation & Control AUTOMOBILE EXHAUST GAS ANALYZER MODEL : ZKE23:(CO/HC/CO2) ZKE24:(CO/HC/CO2/O2) About 25 years have passed since Fuji Electric first marketed a CO/HC automobile exhaust gas analyzer. The high-level technology incorporated in these |
Original | ||||
| Amphenol Advanced Sensors ® 6713 CO2 Module NDIR | Amphenol Advanced Sensors ® 6713 CO2 Module NDIR CO2 Module designed for applications that require high accuracy in a compact package The Telaire ® T6713 CO 2 is ideal for applications where CO 2 levels need to be measured and controlled for indoor air quality |
Original | ||||
| LMP91051 www.ti.com SNAS581B – MARCH 2012 – | LMP91051 www.ti.com SNAS581B – MARCH 2012 – REVISED MAY 2013 LMP91051 Configurable AFE for Nondispersive Infrared (NDIR) Sensing Applications Check for Samples: LMP91051 FEATURES 1 • 2 Dual Channel Input Programmable Gain Amplifier |
Original | ||||
| PORTABLE GAS ANALYZER DATA SHEET ZFY This unit is | PORTABLE GAS ANALYZER DATA SHEET ZFY This unit is a simple and stable analyzer using a single-beam infrared-ray system. It is designed for measuring carbon dioxide gas (CO2), carbon monoxide (CO) or methane (CH4), and is used to measure atmospheric gases in agricultural |
Original | ||||
| co sensor | CO/O2 GAS ANALYZER FOR STACK GAS DATA SHEET ZSW This instrument is equipped with a non-dispersive infrared CO sensor and a galvanic oxygen sensor and used for measuring CO and O2 in the gas emitted from garbage incinerators. CO instantaneous value, O2 instantaneous value and CO |
Original | ||||
| tps 4339 | Lighting | Imaging | Telecom p Thermopile Infrared Detectors Quad Thermopile TPS 4339 Thermistor temperature reference included Internal aperture to avoid cross talk Standard gas filter sets for reference, CO, hydrocarbon, CO2 The quad thermopile sensor consists of four single thermopile chips mounted in a TO 5 |
Original | ||||
| tps 4339 | TPS 4339 - Quad Thermopile Four Individual Thermopiles with Different Infrared Bandpass Filters D A T A S H E E T Optoelectronics Description Features The TPS 4339 quad thermopile sensor consists of four single thermopile chips mounted in a TO 5 housing with a |
Original | ||||