Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    NDIR GAS SENSOR Search Results

    NDIR GAS SENSOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCTH022BE
    Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function Datasheet
    TCTH021BE
    Toshiba Electronic Devices & Storage Corporation Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type Datasheet
    COMBOSENSOR
    Texas Instruments XTR117 XTR117 4-20mA Current Loop Transmitter Visit Texas Instruments
    COMBOBODYSENSOR
    Texas Instruments ADS1292 Complete Low Power Integrated Analog Front End for ECG Applications Visit Texas Instruments
    V62/20606-01EX
    Texas Instruments Enhanced product, low-power, analog temperature sensor Visit Texas Instruments Buy

    Documents mentioning NDIR GAS SENSOR

    Document Partial File Text Tags Type PDF
    ndir gas sensor
    Visible/IR Lamps for NDIR Gas Sensors Gilway offers a line of Visible/IR lamps for use in applications such as nondispersive infrared gas sensors, analyzers, and monitors. Nondispersive Infrared (NDIR) sensors are simple spectroscopic devices often used for gas analysis.
    Original PDF
    MICROPROCESSOR BASED NDIR GAS ANALYZER DATA SHEET
    MICROPROCESSOR BASED NDIR GAS ANALYZER DATA SHEET ZRF This NDIR gas analyzer features a high accuracy, multiple functions and easy operation through use of a microprocessor. It also utilizes a mass flow detector noted for its high sensitivity and reliability. Being housed in a 19 inch rack case suitable
    Original PDF
    gas sensor
    Overview PerkinElmer has designed a new Natural Gas Alarm Sensor in response to OEMs’ needs for highly reliable solution for natural gas detection. The Natural Gas Alarm sensor, as part of the Gas Sensor family, uses nondispersive infrared radiation (NDIR) and
    Original PDF
    gas analyzer
    NDIR TYPE INFRARED GAS ANALYZER DATA SHEET ZRH This NDIR gas analyzer is used for measuring CO2, CO, SO2 and CH4 and features a high accuracy, multiple functions and easy operation through use of a microprocessor. It is housed in a 19 inch rack case suitable for mounting on a panel
    Original PDF
    infrared gas analyzer
    NDIR TYPE INFRARED GAS ANALYZER (5-COMPONENT ANALYZER) DATA SHEET This gas analyzer (ZKJ) is capable of measuring the concentrations of NO, SO 2, CO 2, CO, CH4 and O2 components in sample gas. NO, SO2, CO2, CO and CH4 are measured by non-dispersion infrared method (NDIR), while O 2 is measured by built-in
    Original PDF
    infrared gas analyzer
    NDIR TYPE INFRARED GAS ANALYZER DATA SHEET ZRG This NDIR gas analyzer features high accuracy, multiple functions and easy operation through use of a microprocessor. It also utilizes a mass flow detector noted for its high sensitivity and reliability. This analyzer is used not only for measuring environmental pollution but is also used for various processes and/or
    Original PDF
    infrared gas analyzer
    NDIR TYPE INFRARED GAS ANALYZER DATA SHEET ZRC6 This infrared gas analyzer measures the concentration of gas by utilizing the characteristic of gas (molecule consisting of different-kind atoms) that it absorbs the infrared ray of a specific wavelength. Stable and accurate measurement is ensured due to use
    Original PDF
    tps 2534
    Lighting | Imaging | Telecom p Thermopile Infrared Detectors Dual Channel Thermopile TPS 2534 Thermistor temperature reference included Applications: infrared absorption (NDIR) gas sensing with reference channel The dual thermopile sensor TPS 2534 employs two single thermopile chips
    Original PDF
    INFRARED GAS ANALYZER DATA SHEET ZRJ This gas
    INFRARED GAS ANALYZER DATA SHEET ZRJ This gas analyzer (ZRJ) is capable of measuring the concentrations of CO2, CO, CH4,SO2 and O2 components in sample gas. CO2, CO, CH4 and SO2 are measured by non-dispersion infrared method (NDIR), while O2 is measured by paramagnetic or zirconia method. A maximum of 4 components including O2 (max. 3 components except for O2 measurement)
    Original PDF
    ir1011
    [IR1011] IR1011 Photovoltaic Infrared Sensor GENERAL DESCRIPTION IR1011 is the world smallest mid-infrared quantum photo diode, made of InSb. This surface mount type sensor can be operated at room temperature, and applicable to human body detection, non-contacting temperature measurement, and NDIR gas sensor.
    Original PDF
    ndir
    Advance Cemas-NDIR Multi component Measuring System for Emission Monitoring and Process Control Specification Sheet 10/23 8.20 EN July 2002 n Complete analyzer system with gas sampling, sample conditioning, analyzer and system control unit in a single cabinet
    Original PDF
    ir33b
    IR3xxx Series, IR4xxx Series Miniature Infrared Gas Sensors for Non-Hazardous Areas FEATURES * * * * * * * * * * * * * * * * * * * Configured for carbon dioxide (IR31BC, IR41BC), hydrocarbons (IR32BC, IR33BC, IR42BC, IR43BC) or acetylene (IR34BC, IR44BC) Sensing ranges: 0 – 2% vol. (optional 0 – 5% vol.) for CO2,
    Original PDF
    IR15TT, IR15TT-M, IR25TT, IR25TT-M Miniature
    IR15TT, IR15TT-M, IR25TT, IR25TT-M Miniature Infrared Twin-Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining FEATURES * * * * * * * * * * * * * * * * * * * * * * * * * Two active gas channels for simultaneous detection of carbon dioxide, methane and hydrocarbons
    Original PDF
    ir10100
    — Mixed Signal & Sensor Solutions IR 10100 PRODUCT BRIEF InSb Mid-Infrared Sensor Description The IR10100 is the smallest photovoltaic midinfrared sensor, based on an evolutionary InSb p-i-n structure. It detects wavelength from 2 to 7|jm at room tem perature, suitable for human body
    OCR Scan PDF
    zke24
    Fuji Instrumentation & Control AUTOMOBILE EXHAUST GAS ANALYZER MODEL : ZKE23:(CO/HC/CO2) ZKE24:(CO/HC/CO2/O2) About 25 years have passed since Fuji Electric first marketed a CO/HC automobile exhaust gas analyzer. The high-level technology incorporated in these
    Original PDF
    Amphenol Advanced Sensors ® 6713 CO2 Module NDIR
    Amphenol Advanced Sensors ® 6713 CO2 Module NDIR CO2 Module designed for applications that require high accuracy in a compact package The Telaire ® T6713 CO 2 is ideal for applications where CO 2 levels need to be measured and controlled for indoor air quality
    Original PDF
    LMP91051 www.ti.com SNAS581B – MARCH 2012 –
    LMP91051 www.ti.com SNAS581B – MARCH 2012 – REVISED MAY 2013 LMP91051 Configurable AFE for Nondispersive Infrared (NDIR) Sensing Applications Check for Samples: LMP91051 FEATURES 1 • 2 Dual Channel Input Programmable Gain Amplifier
    Original PDF
    PORTABLE GAS ANALYZER DATA SHEET ZFY This unit is
    PORTABLE GAS ANALYZER DATA SHEET ZFY This unit is a simple and stable analyzer using a single-beam infrared-ray system. It is designed for measuring carbon dioxide gas (CO2), carbon monoxide (CO) or methane (CH4), and is used to measure atmospheric gases in agricultural
    Original PDF
    co sensor
    CO/O2 GAS ANALYZER FOR STACK GAS DATA SHEET ZSW This instrument is equipped with a non-dispersive infrared CO sensor and a galvanic oxygen sensor and used for measuring CO and O2 in the gas emitted from garbage incinerators. CO instantaneous value, O2 instantaneous value and CO
    Original PDF
    tps 4339
    Lighting | Imaging | Telecom p Thermopile Infrared Detectors Quad Thermopile TPS 4339 Thermistor temperature reference included Internal aperture to avoid cross talk Standard gas filter sets for reference, CO, hydrocarbon, CO2 The quad thermopile sensor consists of four single thermopile chips mounted in a TO 5
    Original PDF
    tps 4339
    TPS 4339 - Quad Thermopile Four Individual Thermopiles with Different Infrared Bandpass Filters D A T A S H E E T Optoelectronics Description Features The TPS 4339 quad thermopile sensor consists of four single thermopile chips mounted in a TO 5 housing with a
    Original PDF