    DCL540H01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: High / Output enable Datasheet
    DCL541L01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Output enable Datasheet
    DCL542L01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=2:2) / Default Output Logic: Low / Output enable Datasheet
    DCL542H01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=2:2) / Default Output Logic: High / Output enable Datasheet
    DCL540L01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: Low / Output enable Datasheet

    NAMUR OUTPUT Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: NAMUR Hazardous Location Sensors Sensor Systems NAMUR refers to the standards committee of measurement and control of the chemical industry of Europe. Namco sensors comply with DIN 19234 and therefore are compatible with the NAMUR requirements. NAMUR sensors are typically used


    Original
    EE931-02103 EE931-02303 EE931-Series 1-800-NAMTECH PDF

    baumer electric sensor proximity

    Abstract: EC certificate PTB ATEX 1144 X DETECTEUR Baumer CH-8501 inductive EC certificate PTB 03 ATEX 2146
    Contextual Info: Induktive Sensoren Inductive sensors Détecteurs inductifs Elektrischer Anschluss Connection diagram Schéma de raccordement Abmessungen Dimensions Dimensions IFRM 08X9501/S35 BK NAMUR Näherungsschalter NAMUR 0V 35 50 SW 13 Détecteur de proximité NAMUR


    Original
    08X9501/S35 CH-8501 D-38116 baumer electric sensor proximity EC certificate PTB ATEX 1144 X DETECTEUR Baumer CH-8501 inductive EC certificate PTB 03 ATEX 2146 PDF

    Inductive proximity switch

    Abstract: DJ6G transistor DJ marking DJ10 DIN19234
    Contextual Info: Proximity Sensors Inductive Nickel-plated Brass Housing Types DJ, M 14, PG 21, Namur • Nickel-plated brass housing, cylindrical • Diameter: M 14, PG 21 • Sensing distance: 2 to 6 mm • Power supply: 8.2 VDC Namur • Output: Namur (DIN 19 234) • 2 m cable


    Original
    PDF

    EC certificate PTB 03 ATEX 2146

    Abstract: baumer electric sensor proximity DETECTEUR facon ga 44 CH-8501 Frauenfeld EC certificate PTB ATEX 2146 Baumer inductive SENSOR CH-8500 baumer electric ch-8501 frauenfeld
    Contextual Info: Induktive Sensoren Inductive sensors Détecteurs inductifs Elektrischer Anschluss Connection diagram Schéma de raccordement Abmessungen Dimensions Dimensions IFRM 08X9503/S35 BK NAMUR 0V 41 25 SW 13 Proximity sensor NAMUR Détecteur de proximité NAMUR 10235313


    Original
    08X9503/S35 CH-8501 D-38116 EC certificate PTB 03 ATEX 2146 baumer electric sensor proximity DETECTEUR facon ga 44 CH-8501 Frauenfeld EC certificate PTB ATEX 2146 Baumer inductive SENSOR CH-8500 baumer electric ch-8501 frauenfeld PDF

    Namur isolating switching amplifier

    Abstract: namur output DIN19234 IM12-02B-N-ZW0 IM12-04N-N-ZW0
    Contextual Info: IM 12 NAMUR Inductive Proximity Sensors DC Highlights • Shielded or unshielded • Enclosure rating IP 67 • NAMUR to DIN 19 234 • LED status indicator • High switching frequency • Robust brass housing with nickel=plated fine thread M8 x 1 IM 12 NAMUR


    Original
    M12x1 IM12-02B-N-ZW0 IM12-04N-N-ZW0 Namur isolating switching amplifier namur output DIN19234 IM12-02B-N-ZW0 IM12-04N-N-ZW0 PDF

    namur standard

    Abstract: namur 0601
    Contextual Info: Proximity Sensors Inductive Stainless Steel Housing Types EI, Ø 6.5, M8, NAMUR • Stainless steel housing, cylindrical • Diameter: Ø 6.5, M8 • Short versions • Sensing distance: 1 to 2 mm • Output: NAMUR DIN 19234 • Protection: Reverse polarity


    Original
    PDF

    transistor BU 102

    Abstract: bk 101 transistor SS TRANSISTOR DIN19234
    Contextual Info: Proximity Sensors Inductive ABS Housing Type DU, Fork-shaped • Fork-shaped ABS housing • Slot sizes: 3.5, 5, 6, 10 mm • Power supply: 8.2 VDC NAMUR 24 VDC • Output: NAMUR (DIN 19234) Transistor NPN, make switching • Protection: Reverse polarity


    Original
    PDF

    namur standard

    Abstract: namur N00219 efector namur out put nv0201 5501 led display EFECTOR proximity BS5501 capteur de proximity
    Contextual Info: R Schaltverstärker NAMUR EN 50227 N 00219 107 22 42 2-kanalig [EEx ia / ib] IIC \DATEN\100\DB-FORMPZD/02/06/95 Normen und Richtlinien 87 35,5 Steuerstromkreis zugelassen für Zone 0 102 NAMUR Schaltverstärker NV 0201 Befestigung auf Tragschiene Der NAMUR-Verstärker NV 0201 erfüllt alle


    Original
    \DATEN\100\DB-FORM--PZD/02/06/95 namur standard namur N00219 efector namur out put nv0201 5501 led display EFECTOR proximity BS5501 capteur de proximity PDF

    proximity switch wiring

    Abstract: namur DR RELAYS namur output
    Contextual Info: Proximity Sensors Capacitive Thermoplastic Polyester Housing Types DR 6, DR 10, Ø22, Ø30, Namur • Thermoplastic polyester housing, cylindrical • Diameter: Ø22, Ø30 • Sensing distance: 5 - 10 mm • Output: Namur DIN 19 234 • 2 m cable Product Description


    Original
    SD110/210. proximity switch wiring namur DR RELAYS namur output PDF

    inductive proximity sensor

    Abstract: namur output namur
    Contextual Info: Proximity Sensors Inductive High Temperature Types IA, M12, NAMUR • • • • • • Nickel-plated brass housing Sensing distance: 2 mm Power supply: 8 VDC Output: NAMUR For flush mounting 2 m silicone cable Product Description Ordering Key Inductive proximity sensor


    Original
    PDF

    Contextual Info: Proximity Sensors Inductive Thermoplastic Polyester Housing Types IA, M12, M18 and M30, NAMUR • Euronorm thermoplastic polyester housing, cylindrical • Short or long versions • Diameter: M12, M18, M30 • Sensing distance: 2 to 15 mm • Output: NAMUR EN 50 227


    Original
    PDF

    Contextual Info: Proximity Sensors Inductive High Temperature Types IA, M12, NAMUR • • • • • • Nickel-plated brass housing Sensing distance: 2 mm Power supply: 8 VDC Output: NAMUR For flush mounting 2 m silicone cable Product Description Ordering Key Inductive proximity sensor


    Original
    mounti-25Â PDF

    EC certificate PTB 03 ATEX 2146

    Abstract: EC certificate PTB ATEX 1144 X baumer electric CH-8501 cable baumer electric sensor proximity
    Contextual Info: Induktive Sensoren Inductive sensors Détecteurs inductifs Elektrischer Anschluss Connection diagram Schéma de raccordement Abmessungen Dimensions Dimensions IFRM 12X9503 BK NAMUR Näherungsschalter NAMUR BU BK = Schwarz/black/noir BU = Blau/blue/bleu 0V


    Original
    12X9503 2002/95/EC CH-8501 54/9/CE D-38116 EC certificate PTB 03 ATEX 2146 EC certificate PTB ATEX 1144 X baumer electric CH-8501 cable baumer electric sensor proximity PDF

    Contextual Info: Proximity Sensors Inductive Stainless Steel Housing Types IA, M12, M18 and M30, NAMUR • Stainless steel housing, cylindrical • Diameter: M12, M18, M30 • Short or long versions • Sensing distance: 2 to 15 mm • Output: NAMUR EN 50 227 • Protection: Reverse polarity


    Original
    PDF

    MQD9-415

    Abstract: MIAD9DQ MIAD9D Quick disconnect QD connector Ex-94.C.7937 VOC sensor dc sensors MIAD9CVQ FM3610 40143
    Contextual Info: MIAD9 Series NAMUR Intrinsically Safe DC Sensors* MIAD9 Series NAMUR Sensors are small, rugged, self-contained twowire sensors designed for use with approved switching amplifiers with intrinsically safe input circuits. MIAD9 Series sensors are designed in


    Original
    SMB312S 15-turn MQD9-415 MIAD9DQ MIAD9D Quick disconnect QD connector Ex-94.C.7937 VOC sensor dc sensors MIAD9CVQ FM3610 40143 PDF

    Contextual Info: Capacitive Proximity Sensors M30 Capacitive Proximity Sensors Standard Length Metal Housing 3 Wire DC 2 Wire AC NAMUR ABS and Teflon housing available NAMUR 3 Wire DC 2 Wire DC 3 CPM723015C PNP – Normally Open (1) CPM323020C CPM323020M12 CPM323020P CPM323020C.A


    Original
    CPM723015C CPM323020C CPM323020M12 CPM323020P CPM323020C CPM333020C CPM333020M12 CPM333020P CPM333020C CPM343020C PDF

    inductive proximity sensor

    Abstract: "inductive Proximity Sensor" PROX 120 proximity switch wiring namur
    Contextual Info: Proximity Sensors Inductive High Temperature Types IA, M12, NAMUR • Nickel-plated brass housing • Sensing distance: 2 mm • Power supply: 8 VDC • Output: Namur • For flush mounting • 2 m silicone cable Product Description Ordering Key IA 12 ASF 02 UHT-K


    Original
    PDF

    EC certificate PTB 03 ATEX 2146

    Abstract: EC certificate PTB ATEX 1144 X EC certificate PTB ATEX 2146 baumer electric sensor proximity Baumer ifrm DETECTEUR
    Contextual Info: Induktive Sensoren Inductive sensors Détecteurs inductifs Elektrischer Anschluss Connection diagram Schéma de raccordement Abmessungen Dimensions Dimensions IFRM 18X9103 BK NAMUR Näherungsschalter NAMUR +V S RL BU BK = Schwarz/black/noir BU = Blau/blue/bleu


    Original
    18X9103 2002/95/EC CH-8501 D-38116 EC certificate PTB 03 ATEX 2146 EC certificate PTB ATEX 1144 X EC certificate PTB ATEX 2146 baumer electric sensor proximity Baumer ifrm DETECTEUR PDF

    baumer electric sensor proximity

    Abstract: proximity se EC certificate PTB 03 ATEX 2146 03 atex 1144 x
    Contextual Info: Induktive Sensoren Inductive sensors Détecteurs inductifs Elektrischer Anschluss Connection diagram Schéma de raccordement Abmessungen Dimensions Dimensions IFRM 18X9103 BK NAMUR Näherungsschalter NAMUR +V S RL BU BK = Schwarz/black/noir BU = Blau/blue/bleu


    Original
    18X9103 CH-8501 D-38116 baumer electric sensor proximity proximity se EC certificate PTB 03 ATEX 2146 03 atex 1144 x PDF

    Contextual Info: Capacitive Proximity Sensors M18 Capacitive Proximity Sensors Standard Length NAMUR 3 Wire DC ABS Material PTFE Material NAMUR 3 Wire DC 2 Wire DC Wiring Schematic CPN72185C (1) CPN32188C CPN32188M12 CPN32188C.A CPN32188C.F PNP – Normally Closed (1) CPN33188C


    Original
    CPN72185C CPN32188C CPN32188M12 CPN32188C CPN33188C CPN33188M12 CPN33188C CPN34188C PDF

    ei 3015 nacs

    Abstract: 0601 ei 1202 namur standard ei1202nacs NACS EI 54 EI1805NACS EI 30
    Contextual Info: Proximity Sensors Inductive Stainless Steel Housing Types EI, Ø 6.5, M 8, M 12, M 18, M 30, Namur • Stainless steel housing, cylindrical • Diameter: Ø 6.5, M 8, M 12, M 18, M 30 • Short versions • Sensing distance: 1 to 15 mm • Output: Namur DIN 19234


    Original
    18/EI ei 3015 nacs 0601 ei 1202 namur standard ei1202nacs NACS EI 54 EI1805NACS EI 30 PDF

    SJ10E

    Abstract: SJ30 SJ15
    Contextual Info: Inductive Proximity Sensors Slot sensors are designed to meet IP67 ratings and are protected against shock, vibration, and contamination. We offer 3- and 4-wire DC models, 2-wire AC and NAMUR output style sensor. All are CE and UL listed. See our NAMUR product section for available slot sensors with


    Original
    sensorsaredesignedtomeetIP67ratingsandare approximately60% SJ15-E SJ15-E2 SJ15-WS SJ15-WO SJ10E SJ30 SJ15 PDF

    baumer electric sensor proximity

    Abstract: EC certificate PTB 03 ATEX 2146
    Contextual Info: Induktive Sensoren Inductive sensors Détecteurs inductifs Elektrischer Anschluss Connection diagram Schéma de raccordement Abmessungen Dimensions Dimensions IFRM 06X9503/P BK NAMUR Näherungsschalter NAMUR +V S RL BU BK = Schwarz/black/noir BU = Blau/blue/bleu


    Original
    06X9503/P CH-8501 D-38116 baumer electric sensor proximity EC certificate PTB 03 ATEX 2146 PDF

    EI0802NACS

    Abstract: Inductive proximity switch NACS
    Contextual Info: Proximity Sensors Inductive Stainless Steel Housing Types EI, Ø 6.5, M 8, M 12, M 18, M 30, Namur • Stainless steel housing, cylindrical • Diameter: Ø 6.5, M 8 • Short versions • Sensing distance: 1 to 2 mm • Output: Namur DIN 19234 • Protection: Reverse polarity


    Original
    PDF