Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MODEM WESTERMO Search Results

    MODEM WESTERMO Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-DSNULW29FF-005
    Amphenol Cables on Demand Amphenol CS-DSNULW29FF-005 DB9 Female to DB9 Female Null Modem Cable - Double Shielded - Full Handshaking 5ft PDF
    CS-DSNULW19MF-025
    Amphenol Cables on Demand Amphenol CS-DSNULW19MF-025 DB9 Male to DB9 Female Null Modem Cable - Double Shielded - No Handshaking 25ft PDF
    CS-DSNULW29MF-005
    Amphenol Cables on Demand Amphenol CS-DSNULW29MF-005 DB9 Male to DB9 Female Null Modem Cable - Double Shielded - Full Handshaking 5ft PDF
    CS-DSNL4259MF-010
    Amphenol Cables on Demand Amphenol CS-DSNL4259MF-010 DB25 Male to DB9 Female Null Modem Cable - Double Shielded - Full Handshaking 10ft PDF
    CS-DSNULW29MF-025
    Amphenol Cables on Demand Amphenol CS-DSNULW29MF-025 DB9 Male to DB9 Female Null Modem Cable - Double Shielded - Full Handshaking 25ft PDF

    Documents mentioning MODEM WESTERMO

    Document Partial File Text Tags Type PDF
    td-36
    Advanced telephone- and leased line modem for industrial applications TD-36 485 Modem for industrial PSTN- and 2/4-wire leased line applications The TD-36 485 is an analogue V.34 PSTN modem as well as an industrial 2/4-wire leased line modem. V.34 provides data
    Original PDF
    td-36
    Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased line modem. V.34 provides data rates up to 33.6kbit/s on the communication line. Several
    Original PDF
    td-35
    TD-35 Industrial High Speed PSTN/Leased Line modem The TD-35 is a high quality V.34 PSTN and leased line modem designed for use in harsh industrial environments. To make installation and maintenance easy all the connections are at the front and the modem is designed to snap easily onto a DIN rail.
    Original PDF
    td-36
    TD-36 6618-2201 TD-36 DIN-rail Tele and Leased Line modem TD-36 485 DIN-rail Tele and Leased Line modem with I/O and RS-485 www.westermo.com © Westermo Teleindustri AB • 2006 User Guide Legal information The contents of this document are provided “as is”. Except as required by applicable
    Original PDF
    td-36
    6618-3201 TDW-33 TD-36, TR-36 4 3 2 1 4 3 2 1 Industrial Telephone Modem www.westermo.com © Westermo Teleindustri AB • 2007 AT Commands Interface Guide Introduction This document describes the AT-commands that can be used to configure and control the TDW-33, TD-36 and TR-36 modem.
    Original PDF
    odw-621
    ODW-621/631 Fibre Optic Modem 6650-2221 Industrial Converter Serial to Fibre optic link. Point to point applications www.westermo.com © Westermo Teleindustri AB • 2006 User Guide Legal information The contents of this document are provided “as is”. Except as required by applicable
    Original PDF
    westermo
    TDW-33 6619-2201 DIN-rail Tele V.90 modem www.westermo.com © Westermo Teleindustri AB • 2006 User Guide Legal information The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to,
    Original PDF
    tdw-33
    TDW-33 6619-2201 DIN-rail Tele V.90 modem www.westermo.com © Westermo Teleindustri AB • 2006 User Guide Legal information The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to,
    Original PDF
    odw-632
    Fibre Optic Modem ODW-632 RS-422/485 to fibre optic link, redundant ring or multidrop applications The ODW-632 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces. The ODW-632 is designed for harsh industrial
    Original PDF
    ed-200
    ED-200 Ethernet Router … Field of application Ethernet Router RS-232 or RS-422 serial interface Up to 115.2 kbit/s Integrated 4 port plug and play switch Point to point applications Modem initialisation support
    Original PDF
    odw-622
    Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces. The ODW-622 is designed for harsh industrial usage as well as road or railway installations meeting
    Original PDF
    TDW-33 Telephone modem, RS-232 … Extended
    TDW-33 Telephone modem, RS-232 … Extended temperature range –25°C to +70°C Data rate up to 56 kbit/s (V90) Terminal rate up to 115.2 kbit/s DTR and incoming data dialling Watchdog Secure call back and access Industrial environment transient protection
    Original PDF
    westermo
    W-OM-001 Rev. 3 Westermo Modems and Omron PLC’s AppNote Contents and Contact Details Title…………………………………………………………. 1 Contents and Contact Details…………………………….2 Introduction………………………………………… 3
    Original PDF
    MD- 45 Converter Transmission Interface 1
    MD- 45 Converter Transmission Interface 1 Technical data Asynchronous, full/half duplex or simplex EIA RS-232-C/ITU-T V.24, 9-position D-sub, female, or 9-position screw block EIA RS-422/RS-485/ITU-T V.11, 5-position screw block Up to 115.2 kbit/s Power, RD, CTS, RTS, TD
    Original PDF
    md-12
    Application Asynchronous Modems MD-12, MD-12DC Point-to-point communication is often used to communicate over long distances between different units, e.g. a computer, a printer or a robot. These modems allow you to extend the distance to18,000 m, with a transmission speed of up to 38,400 bit/s. The modems are intended for use
    Original PDF
    ED-10 UDP Industrial Ethernet Adapter The ED-10
    ED-10 UDP Industrial Ethernet Adapter The ED-10 is an Industrial Ethernet to serial interface adaptor; it allows almost any serial device to be connected to a new or existing Ethernet network. The unit can support either RS-485/422 or RS-232 running up to 115.2 kbits/s on the serial port and has a 10BaseT Ethernet connection.
    Original PDF
    6873-sg004h-en-p
    2009 Europe, Middle East & Africa Edition Publication 6873-SG004H-EN-P – June 2009 Supersedes Publication 6873-SG004G-EN-P – January 2008 Copyright ©2009 Rockwell Automation, Inc. All Rights Reserved. Printed in USA. Encompass Program Product Directory
    Original PDF
    current loop converter
    Application 20 mA Current Loop Converter MD-21, MD-21DC These modems are used for different cash register systems (shops) and in certain industrial robot and PLC systems. The converter has a 20 mA current loop interface and an RS-232/V.24 interface. It is most commonly
    Original PDF
    ma-12dc
    Application Asynchronous Modems MA-12, MA-12DC, MA-19 Point-to-point communication is often used to communicate over long distances between different units, e.g. a computer, a printer or a robot. These modems allow you to extend the distance to 18,000 m, with a
    Original PDF
    current loop converter
    Application 20 mA Current Loop Converter MA-21, MA-21DC, MA-29 These modems are used for different cash register systems (shops) and in certain industrial robot and PLC systems. The converter has a 20 mA current loop interface and an RS-232/V.24 interface. It is most commonly
    Original PDF
    rd-48dc
    Application RS-422/485 Repeaters RD-48, RD-48DC These repeaters are used to extend an RS-422/485 bus or as converters between two- and four-wire applications. According to the standard, RS-422/485 can handle 32 devices at a distance of 1,200 m. One or several
    Original PDF
    Datum 980205 PRODUKTINFORMATION FRÅN HÄMTFAX +46
    Datum 980205 PRODUKTINFORMATION FRÅN HÄMTFAX +46 8 735 35 33 FAX ON DEMAND +46 8 735 35 29 INTERNET http://www.elfa.se TEKNISK INFORMATION +46 8 735 35 15 ORDERTEL +46 8 735 35 35 ORDERFAX +46 8 730 30 88 Vi reserverar oss mot fel samt förbehåller oss rätten till ändringar utan föregående meddelande
    Original PDF
    ed-12
    INSTALLATION MANUAL 6609-2250 Galvanic Isolation Transient Protection Balanced Transmission CE Approved Industrial Ethernet adapter – Dual serial channels www.westermo.com © Westermo Teleindustri AB • 2003 • REV.A ED-12 TCP Contents 1. Introduction
    Original PDF
    mdw-45
    MDW-45 6617-2202 Converter RS-232 – RS-422/485 www.westermo.com © Westermo Teleindustri AB • 2005 User Guide Safety ! Before using this unit: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe
    Original PDF
    ddw-100
    DDW-100 6621-2202 Industrial Ethernet SHDSL Extender www.westermo.com © Westermo Teleindustri AB • 2006 User Guide Legal information The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to,
    Original PDF