MEDER REED SENSOR Search Results
MEDER REED SENSOR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCTH022BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type / FLAG signal latch function | Datasheet | ||
| TCTH021BE | Toshiba Electronic Devices & Storage Corporation | Over Temperature Detection IC / VDD=1.7~5.5V / IPTCO=10μA / IDD=11.3μA / Open-drain type | Datasheet | ||
| COMBOSENSOR | Texas Instruments | XTR117 XTR117 4-20mA Current Loop Transmitter |
|
||
| COMBOBODYSENSOR | Texas Instruments | ADS1292 Complete Low Power Integrated Analog Front End for ECG Applications |
|
||
| V62/20606-01EX | Texas Instruments | Enhanced product, low-power, analog temperature sensor |
|
|
Documents mentioning MEDER REED SENSOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| reed switch | MEDER electronic group Copy right: John Beigel, MEDER electronic group http://www.meder.com Reed Switch Basics part III 04/03/2010 Table of contents • Dynamic Contact Resistance • The Reed Switch as Reed Relay • The Reed Switch as Reed Sensor Copy right: John Beigel, |
Original | ||||
| SHORTFORM CATALOG Reed Relays · Reed Sensors · | SHORTFORM CATALOG Reed Relays · Reed Sensors · Reed Switches www.meder.com SELECTION GUIDE MEDER electronic How to Use This Selection Guide Vision Statement The information provided within this Short Form Catalog gives a general overview of MEDER electronic‘s Standard |
Original | ||||
| meder | MEDER electronic group Copy right: John Beigel, MEDER electronic group http://www.meder.com Reed Switch Basics part I 08/01/2010 Table of contents • What is a Reed Switch? Reed Switch Basic Structure Reed Switch Lead Material - Ruthenium |
Original | ||||
| meder | MEDER electronic group Copy right: John Beigel, MEDER electronic group http://www.meder.com Reed Switch Basics part II 04/02/2010 Table of contents • Reed Switch Operating Characteristics • Pull-in / Drop-out • Hysteresis • Parameters of a Reed Switch |
Original | ||||
| d-78224 | Firmenpräsentation www.meder.com MEDER electronic AG Robert-Bosch-Strasse 4 D-78224 Singen/Htwl. Germany Phone: + 49 (0) 7731-8399-0 Fax: REED RELAIS - REED SENSOREN - REED SCHALTER + 49 (0) 7731-8399-30 Januar 2009 Unternehmens-Philosophie MEDER electronic AG ist ein führendes, sehr innovatives |
Original | ||||
| metal detection | Sensing the Closure Closure of Fire, Safety, and Emergency Doors Using MEDER’s Unique Ferromagnetic Metal Detection Sensors REED RELAYS REED SENSORS REED SWITCHES Introduction Figure 1. Screw mount version diagram of MK02 Series metal detection reed sensors |
Original | ||||
| reed switch | MEDER electronic REED SWITCH CHARACTERISTICS Reed Switch Operational Characteristics Introduction The Reed Switch was first invented by Bell Labs in the late 1930s. However, it was not until the 1940s when it began to find application widely as a sensor and a Reed |
Original | ||||
| PRODUKTÜBERSICHT Reed Relais · Reed Sensoren · | PRODUKTÜBERSICHT Reed Relais · Reed Sensoren · Reed Schalter www.meder.com AUSWAHLHILFE MEDER electronic Auswahlhilfe Im folgenden Abschnitt stellen wir unsere Standard-Reedprodukte und ihre Spezifikationen in Übersichtsform dar. Diese Produkte repräsentieren nur einen kleinen Teil des |
Original | ||||
| reed switch | REED SWITCH CHARACTERISTICS MEDER electronic How Reed Switches are used with a Permanent Magnet Using Reed Switches in a sensing environment, one generally uses a magnet for actuation. It is important to understand this interaction clearly for proper sensor |
Original | ||||
| reed switch | REED SWITCH CHARACTERISTICS MEDER electronic How Reed Switches are used with a Permanent Magnet Using Reed Switches in a sensing environment, one generally uses a magnet for actuation. It is important to understand this interaction clearly for proper sensor |
Original | ||||
| reed switch | REED SWITCH CHARACTERISTICS MEDER electronic How Reed Switches are used with a Permanent Magnet Using Reed Switches in a sensing environment, one generally uses a magnet for actuation. It is important to understand this interaction clearly for proper sensor |
Original | ||||
| reed switch | MEDER electronic REED SWITCH CHARACTERISTICS Reed Switch Operational Characteristics Introduction The Reed Switch was first invented by Bell Labs in the late 1930s. However, it was not until the 1940s when it began to find application widely as a sensor and a |
Original | ||||
| smd mounting | MEDER electronic MK17 Series Reed Sensors for SMD Mounting DESCRIPTION MK17 are magnetically operated Reed proximity switches for SMD mounting. APPLICATIONS • Electronic PCB’s where all components are surface mounted • Telecommunication applications |
Original | ||||
| MEDER electronic MK17 Series Reed Sensors for SMD | MEDER electronic MK17 Series Reed Sensors for SMD Mounting DESCRIPTION MK17 are magnetically operated Reed proximity switches for SMD mounting. APPLICATIONS • Electronic PCB’s where all components are surface mounted • Telecommunication applications |
Original | ||||
|
|
||||||
| reed switch | PRECAUTIONS MEDER electronic Handling and Load Precautions when using Reed Switches in various Sensor and Relay Applications Cutting and Bending a Reed Switch Many users of Reed Switches for sensor and reed relay applications try to make the sensors and or relays themselves internally. Often however, they do not observe |
Original | ||||
| reed switch | PRECAUTIONS MEDER electronic Handling and Load Precautions when using Reed Switches in various Sensor and Relay Applications Cutting and Bending a Reed Switch Many users of Reed Switches for sensor and reed relay applications try to make the sensors and or relays themselves internally. Often however, they do not observe |
Original | ||||
| MEDER electronic MK24 Series Micro-Miniature Reed | MEDER electronic MK24 Series Micro-Miniature Reed Sensors for SMD Mounting DESCRIPTION MK24 are the smallest, magnetically operated Reed proximity switches for SMD mounting. Due to the offset design of the internal reed switch leads, the sensing characteristics are non-symmetrically related to the sensor body. |
Original | ||||
| reed switch | SENSOR APPLICATIONS MEDER electronic Reed Switch and Reed Sensor Applications Introduction Reading the previous sections on the Reed Switch basics, key parameters, and operational characteristics before delving into this section will give one a better background and more insight into developing requirements for your own applications. |
Original | ||||
| Liquid Level Sensors Capable of Operating in | Liquid Level Sensors Capable of Operating in Harsh Environments up to 200° 200°C REED RELAYS REED SENSORS REED SWITCHES Introduction High temperature liquid environments have been around for a long time without any accurate, easy method of measuring their liquid levels. MEDER has solved |
Original | ||||
| MEDER electronic MK03 Series Cylindrical Reed | MEDER electronic MK03 Series Cylindrical Reed Sensors DESCRIPTION MK03 sensors are magnetically operated Reed proximity switches in a cylindrical case with an interconnect cable. The sensor should be mounted on a fixed surface with the actuating magnet on |
Original | ||||
| Meder Electronic MK14 Series Cylindrical Reed | Meder Electronic MK14 Series Cylindrical Reed Sensors DESCRIPTION MK14 sensors are magnetically operated Reed proximity switches in a 4.0 mm diameter miniature module, fitted with interconnect cable. The sensor should be mounted on a fixed surface with the |
Original | ||||
| MK9 Series MEDER electronic Reed Sensor | MK9 Series MEDER electronic Reed Sensor Incorporated into a Hirschmann Connector DESCRIPTION MK9 sensors are magnetically operated Reed proximity switches potted into a standard Hirschmann connector casing according to “DIN 43650 / type AM3”. In combination with the |
Original | ||||
| Meder Electronic MK9 Series Reed Sensor | Meder Electronic MK9 Series Reed Sensor Incorporated into a Hirschmann Connector DESCRIPTION MK9 sensors are magnetically operated Reed proximity switches potted into a standard Hirschmann connector casing according to “DIN 43650 / type AM3”. In combination with the |
Original | ||||
| mk18 | MK18 Series MEDER electronic Cylindrical Reed Sensors DESCRIPTION MK18 sensors are magnetically operated Reed proximity switches in a cylindrical module, fitted with interconnect cable. The sensor should be mounted on a fixed surface with the actuating magnet on |
Original | ||||