    DF2B20M4SL
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-18.5 V, SOD-962 (SL2) Datasheet
    DF2B6M4ASL
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) Datasheet
    DF2B7BSL
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) Datasheet
    DF2B7ASL
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-5.5 V, SOD-962 (SL2) Datasheet
    DF2S6P2FU
    Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Unidirectional, 5.5 V, SOD-323 (USC) Datasheet

    Documents mentioning MCB TRIPPING VOLTAGE

    Document Partial File Text Tags Type PDF
    miniature circuit breaker
    Miniature circuit breakers Breaking capacities Tripping characteristics Miniature circuit breaker (magnetic trip setting) Type C60HB MCB (type B: 3-5In) C60HC MCB (type C: 5-10In C60HD MCB (type D: 10-14In) C120 HB MCB C120 HC MCB C120 HD MCB NG125 N NG125 H
    Original PDF
    nc100lma
    Contents Axiom MCB’s features and benefits C60 features and benefits Axiom MCB outgoers C60 MCB outgoers MCB auxiliaries MCB accessories DPN MCB’s NC100 MCB NC100 auxiliaries NC100 accessories NC100LMA P25M P25M accessories P25M auxiliaries 41 42 44-45
    Original PDF
    s500
    Technical catalogue 2010 S800/S500 The High Performance MCB High performance MCB S800 and S500 The S800 and S500 high performance circuit breakers are miniature circuit breakers that restrict current and energy. The maximum rated ultimate short-circuit breaking capacity
    Original PDF
    Technical data Miniature circuit-breakers S 280
    Technical data Miniature circuit-breakers S 280 UC series System pro M Prior to connection of aluminum conductors (ͧ 4 mm2) ensure that their contact points are cleaned, brushed and coated with grease. Conditions for Delivery and Sale For domestic business, the Standard Terms for Delivery of Products and Services of the Electrical
    Original PDF
    I12_018-021_b_G.fm Seite 21 Donnerstag, 16.
    I12_018-021_b_G.fm Seite 21 Donnerstag, 16. September 2004 12:41 12 Add-On Functions Auxiliary Contacts, Voltage Releases, MCB Lock 12/21 Circuit diagram Contacts Space units 1 PLE = 18 mm Qty. PE Type Article no. Price See Price List Std. pack Notes Auxiliary contacts and voltage releases
    Original PDF
    s270
    Line Protection Devices MCB- S270 & S260 series Conforms to IEC60898, IS8828-10kA and IEC60947-2 ABB- the pioneer in MCB technology brings to you the S270 range based on system pro M, a modular system developed by ABB. The S270 range of MCBs are designed and constructed to
    Original PDF
    42062 GE Consumer & Industrial Power Protection
    42062 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection The Power Protection division of GE Consumer & Industrial is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components,
    Original PDF
    vigi c60
    10, 30,100, 300mA VIGI C60 add-on residual current devices BS 4293 Application The new range of VIGI C60 residual current devices simply clip on to the right hand side of any C60HB, C60HC and C60HD mcb, without adaptors, to provide a high level of protection against earth
    OCR Scan PDF
    protection of transformers, primary and secondary
    protection of transformers, primary and secondary circuits ■ Protection of transformers In accordance with the IEC/EN 61558 standard, transformers must be protected against overload and short-circuit conditions which may occur during normal operation. The standard does not specify the type or location of the protective
    Original PDF
    miniature circuit breaker
    MCB tra Combinations Miniature Circuit Breakers PLSM, PLZM MW • High-quality miniature circuit breakers for trade and industry applications • Contact position indicator red - green • Guide for secure terminal connection • 3-position DIN rail clip, permits removal from existing busbar
    Original PDF
    Ready to install Distribution boards, DIN rail mounted equipment, enclosures and connection systems Contents Isobar 4 distribution boards and protective devices Section one 7 Modular control products Section two 31 Unit mounted residual current devices Section three
    Original PDF
    12/037 Moeller HPL0211-2001/2002 FAZ tripping
    12/037 Moeller HPL0211-2001/2002 FAZ tripping characteristics at 30 °C: R to IEC/EN 60 947 1.05 1.30 1.13 1.45 FAZ tripping characteristics at 30 °C: B, C, D to IEC/EN 60 898 Specified non-tripping current I nt = 1.13 ҂ I n for t > 1 h Specified tripping current
    Original PDF
    breakers
    TECHNICAL DATA SHEET Sentry Miniature Circuit Breakers 1:3 Sentry® MCBs Description PRODUCT RANGE Sentry MCBs are of the thermo-magnetic, current limiting type and are available with either Type B or Type C operating characteristics. Type B Single pole Rating
    Original PDF
    hpl0211-2004
    12/0 Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures Moeller HPL0211-2004/2005 For Immediate Delivery call KMParts.com at (866) 595-9616 Overview 12/1 Miniature circuit-breakers MCB enclosures, fuse enclosures
    Original PDF
    rccb
    Circuit protection devices MCBs, RCCBs, RCBO, ELR, surge arresters, fuse carriers, complete range of auxiliaries, busbars and connectors EA 2002/1 Welcome to the new edition of our general catalogue For easy reference purposes, Hager general catalogue is divided into three separate catalogues each representing
    Original PDF
    faz
    12/000 Miniature Circuit-Breakers MCB Enclosures, Fuse Enclosures Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures Moeller HPL0211-2001/2002 12/001 Moeller HPL0211-2001/2002 Miniature circuit-breakers System overview Miniature circuit-breakers FAZ miniature circuit-breakers
    Original PDF
    merlin gerin
    Catalogue 2004 Merlin Gerin Miniature circuit-breakers and earth leakage circuit-breakers (MCBs/ELCBs) contents page Miniature circuit-breakers RCCB / ELCB Technical information Mini pragma din kit Merlin Gerin C60a 2 C60N 3 C60H 4 C60N UL489 - DC circuit breaker
    Original PDF
    c60h
    C60H Miniature circuit breakers Ratings 1 to 63A C60HB type B (3 - 5In) Applications Protection and control of circuits against overloads and short circuits. ■ In applications with general load characteristics. ■ Tripping characteristics: BS EN 60898 type B:
    Original PDF