    MARKING TH8 Search Results

    Documents mentioning MARKING TH8

    Document Partial File Text Tags Type PDF
    TH8 DC HOUR METER TH8 Hour Meter Features 1. IP66
    TH8 DC HOUR METER TH8 Hour Meter Features 1. IP66 waterproof construction The front panel surface keeps water and dust out. Perfect for use in rough conditions. 2. Includes operation light (LED) The operation LED illuminates so you can quickly verify operation status.
    Original PDF
    sel5020
    5-mm pitch lead contact mount LEDs (for automatic insertion) ■SEL5020 series (Flat type) 1.0min 23.0min 4.2±0.5 6.0±0.2 Cathode Cathode mark Resin heap 0.8max 3.3±0.2 0.5±0.1 3.6 0.65max 0.5±0.1 1.4 6.2 (P.5.0) Outline drawing A SEL5420E ■SEL5021 series (ø3 lens type)
    Original PDF
    sml1016
    Bicolor LEDs ■SML1016 series (Standard type) Outline drawing A 2.8 0.8 0.65max 5.0±0.2 7.0±0.5 2.5±0.2 ■SML70020 series (Flat lens type for contact mounting) 0.45±0.1 1.5max Outline drawing D Resin burr 0.3max ø5.0±0.2 Resin burr 0.3max (P.2.54)
    Original PDF
    Round-type contact mount LEDs (for automatic
    Round-type contact mount LEDs (for automatic insertion) 0.8±0.2 23.0min 4.5±0.5 (1.6) 2.5±0.1 1.0min Cathode 4.0±0.2 0.45±0.1 0.4±0.1 0.65max 0.45±0.1 4.0±0.2 (P.2.54) ø3.1±0.1 Cathode 3.5 0.4±0.1 Resin heap 0.8max 4.4 23.0min 5.5±0.5 (1.7) 3.5±0.1
    Original PDF
    SAK-Series SAK-Series Appendix SAK-Series TS 35 A
    SAK-Series SAK-Series Appendix SAK-Series TS 35 A SAK-Series TS 32 B SAK-Series combination foot TS 35 + TS 32 C SAK-Series for special applications D AKZ-Series TS 15 E Multi-pole terminal strips F KLBÜ shielded connection G Busbars / Terminal rails H Accessories
    Original PDF
    HOUR METER TH13·TH23 Hour Meters UL File No.:
    HOUR METER TH13·TH23 Hour Meters UL File No.: E42876 CSA File No.: LR39291 52 2.047 Features 52 2.047 54 2.126 mm inch TH23 series (with reset function) 1. High-performance compact synchronous motor The accurately turning motor is employed to provide for longer period of measurement.
    Original PDF
    th13
    PRECAUTIONS IN USING THE HOUR METERS 1. Frequency setting Frequency is specified for AC motor-driven hour meters. Before installing, be sure to check your local power frequency. 2. Connections • TH13,23,14,24,40,50,63,64 For measuring energized time of load
    Original PDF
    3smc170a
    Central 3SMC5.0A THRU 3SMC170A TM Semiconductor Corp. SURFACE MOUNT UNI-DIRECTIONAL GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR 3000 WATTS, 5.0 THRU 170 VOLTS DESCRIPTION The CENTRAL SEMICONDUCTOR 3SMC5.0A Series types are Surface Mount Uni-Directional Glass Passivated Junction
    Original PDF
    3smc170ca
    Central TM 3SMC5.0CA THRU 3SMC170CA Semiconductor Corp. SURFACE MOUNT BI-DIRECTIONAL GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR 3000 WATTS, 5.0 THRU 170 VOLTS DESCRIPTION The CENTRAL SEMICONDUCTOR 3SMC5.0CA Series types are Surface Mount Bi-Directional Glass Passivated Junction
    Original PDF
    th70
    DIN48 DC TYPE HOUR METER TH70 Hour Meters Features 80.5 3.169 1. Driven on DC power The hour meters can be built in DC-powered control panels. Machine tools and similar machinery are monitored from the control panel for added safety. 2. High-performance compact sync motor with ultra-accurate quartz oscillator
    Original PDF
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA)
    REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Updated boilerplate to include class N. Added case outline X. Editorial changes throughout. – TMH 98-01-27 Monica L. Poelking B Changes in accordance with NOR 5962-R043-99. 99-03-04 Monica L. Poelking
    Original PDF
    th40
    DIN48 DUAL INDICATOR HOUR METER TH40 Hour Meters 80.5 3.169 Features 1. Upgraded composite function Specified-period measurement and total-time measurement can be monitored on a single hour meter. 2. High-performance compact syncronous motor The accurately turning motor is employed to provide for longer
    Original PDF
    din48
    DIN48 MINUTES INDICATOR HOUR METER 80.5 3.169 TH50 Hour Meters Features 1. Measurement and management in units of minutes Unlike conventional hour meters, the time can be measured and managed in minutes. 2. Reset button The hour meters can be reset to zero for repeated measurement.
    Original PDF
    hour meter
    HOUR METER TH13·TH23 Hour Meters UL File No.: E42876 CSA File No.: LR39291 52 2.047 Features 52 2.047 54 2.126 mm inch TH23 series (with reset function) 1. High-performance compact synchronous motor The accurately turning motor is employed to provide for longer period of measurement.
    Original PDF
    lr39291
    DIN48 SIZE HOUR METER TH14·TH24 Hour Meters UL File No.: E42876 CSA File No.: LR39291 80.5 3.169 Features 48 1.890 48 1.890 mm inch Silver panel Black panel TH24 series (with reset button) 1. High-performance compact syncronous motor The accurately turning motor is employed to provide for longer
    Original PDF
    THS8133, THS8133A, THS8133B TRIPLE 10ĆBIT, 80
    THS8133, THS8133A, THS8133B TRIPLE 10ĆBIT, 80 MSPS VIDEO D/A CONVERTER WITH TRIĆLEVEL SYNC GENERATION SLVS204C − APRIL 1999 − REVISED SEPTEMBER 2000 features TQFP-48 PowerPAD™ PACKAGE (TOP VIEW) M2 M1 AVSS ABPb AVDD ARPr AVSS AGY AVDD COMP FSADJ VREF
    Original PDF
    th63
    DIN HALF SIZE HOUR METER TH63·TH64 Hour Meters UL File No.: E42876 CSA File No.: LR39291 57.5 2.264 mm inch 24 .945 48 1.890 TH64 series (with reset button) TH63 series (without reset button) RoHS Directive compatibility information http://www.nais-e.com/
    Original PDF
    ’06–’07 Timers/Time Switches/Counters/Hour Meters
    ’06–’07 Timers/Time Switches/Counters/Hour Meters Timers/Time Switches/Counters/Hour Meters ’06–’07 Please contact… Matsushita Electric Works, Ltd. Automation Controls Business Unit Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan
    Original PDF
    ths8134
    THS8134, THS8134A, THS8134B TRIPLE 8ĆBIT, 80 MSPS VIDEO D/A CONVERTER WITH TRIĆLEVEL SYNC GENERATION SLVS205D − MAY 1999 − REVISED MARCH 2000 features TQFP-48 PowerPAD™ PACKAGE (TOP VIEW) M2 M1 AVSS ABPb AVDD ARPr AVSS AGY AVDD COMP FSADJ VREF D Triple 8-Bit D/A Converters
    Original PDF
    ths8134
    THS8134, THS8134A, THS8134B TRIPLE 8ĆBIT, 80 MSPS VIDEO D/A CONVERTER WITH TRIĆLEVEL SYNC GENERATION SLVS205D − MAY 1999 − REVISED MARCH 2000 features TQFP-48 PowerPAD™ PACKAGE (TOP VIEW) M2 M1 AVSS ABPb AVDD ARPr AVSS AGY AVDD COMP FSADJ VREF D Triple 8-Bit D/A Converters
    Original PDF