MAGNETIC FLOWMETER Search Results
MAGNETIC FLOWMETER Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| RJMG2210D4450ER | Amphenol Communications Solutions | RJ Magnetic (RJMG) - 2xN, Input Output Connectors, 2X1 | |||
| RJMG3266N11G0ER | Amphenol Communications Solutions | RJ Magnetic (RJMG), Input output Connectors, 2X6 10G | |||
| RJMG3211L11D3FR | Amphenol Communications Solutions | RJ Magnetic (RJMG), Input output Connectors, 2x1 10G | |||
| RJMG163217101NR | Amphenol Communications Solutions | RJ Magnetic (RJMG) - 1x1, Input Output Connectors, 10/100 CONNECTOR | |||
| RJMG201821130ER | Amphenol Communications Solutions | RJ Magnetic (RJMG) - 1x1, Input Output Connectors, GIGABIT SINK |
Documents mentioning MAGNETIC FLOWMETER
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| magnetic flow meter | LDCK Magnetic Flow Meter Model LDCK magnetic Flow meter is composed of LDCK Magnetic Flow Transducer and LDCB F1 or F2 Magnetic Flow Converter. It can be used to measure the flow of various media in the pipes. They are corrosive liquids of acid、alkali、salt, |
Original | ||||
| d184b094u02 | Operating Instruction D184B094U02 Valid for Software Versions from A.3X magnetic Flowmeter FXT4000 (COPA-XT) in 2-Wire Technology with Pulsed DC Magnetic Fields Product Designation FXT4000 Operating Instruction Part No. D184B094U02 Issue date: Revision: |
Original | ||||
| flowmeter | Configurable Flowmeter Module (Cat. No. 1771-CFM) Product Data Calculate fast and accurate measurements for your flowĆmetering and/or shaftĆspeed applications. The CFM module interfaces Allen-Bradley programmable logic controllers (PLCs) with magnetic |
Original | ||||
| turbine flowmeter | Specification Turbine Flowmeters Signal Conditioners Series FTSC Main Menu Conditions modulated carrier or magnetic pickoffs Long range transmission, in excess of 1 mile (1.6 km) 10 V pulse output, frequency proportional to flowrate Lightweight polypropylene, Nema 4X or |
Original | ||||
| Solid State Sensors Position Sensors FEATURES • | Solid State Sensors Position Sensors FEATURES • Magnetic sensing using Hall effect technology • 3.8 to 30 volt supply voltages (SS400/ SS100) • Wide variety of package sizes • Sensor only and combination magnet/sensor units • Digital and analog outputs |
OCR Scan | ||||
| Solid State Sensors Position Sensors FEATURES | Solid State Sensors Position Sensors FEATURES OPERATION • Magnetic sensing using Hall effect technology • 4.5 to 24 volt supply voltages • Wide variety of package sizes • Sensor only and com bination m agnet/sensor units • Digital and analog outputs |
OCR Scan | ||||
| gmr sensors | APPLICATION NOTES MAGNETIC SENSORS P R E C I S I O N I N E L E C T R O N I C S GMR sensors Displacement and proximity sensors Sample pressure sensor implementation GMR sensors exhibit excellent linearity and repeatability, and their high sensitivity allows them |
Original | ||||
| oxygen analyzer | PARAMAGNETIC OXYGEN ANALYZER DATA SHEET ZKG This product is a dumbbell type paramagnetic oxygen analyzer. Because this analyzer is based on that the magnetic susceptibility of oxygen gas is larger than coexisting gases, stable measurement is ensured unaffected by coexisting gases. The detector does not have a heating part |
Original | ||||
| ss2-mtg100-0300 | No. SS2-MTG100-0300 MagneW Neo Smart Two-wire magnetic Flowmeter Integral type JIS Explosion-protected Apparatus Model MTG15A OVERVIEW The MagneW Neo is a high performance two wired magnetic flowmeter based on field proven Yamatake two-wire loop powered technologies. |
Original | ||||
| d184s043u02 | Data sheet D184S043U02 magnetic Flowmeter FXT4000 (COPA-XT) 2-Wire Compact Design with Pulsed DC Excitation ■ Function – magnetic flowmeters can be used to accurately measure the flowrate of liquids, pulps, slurries and sludges – Minimum fluid conductivity 20 μS/cm |
Original | ||||
| SIEMENS 6 Silicon Hail-Effect Sensors 6.1 | SIEMENS 6 Silicon Hail-Effect Sensors 6.1 Introduction Silicon Hall-Effect Sensors Electrical Tests and Application Circuit • The sockets or integrated circuits must not be conducting any voltage when individual devices or assembled circuit boards are inserted or withdrawn, unless works’ |
OCR Scan | ||||
| 1771-qrd | AllenĆBradley Pulse Flowmeter Module (Cat. No. 1771-QRD) User Manual Important User Information Because of the variety of uses for this product and because of the differences between solid state products and electromechanical products, those responsible for applying and using this product must satisfy themselves as to the |
Original | ||||
| hall | Silicon Hall-Effect Sensors 6.3 Technology Automotive manufacturers and industry in general are placing ever increasing demands on accurate sensor systems for wheel speed sensing systems, engine and transmission management as well as power steering. In addition such systems are also required for |
Original | ||||
| d184s031u02 | Data Sheet D184S031U02 FieldIT magnetic Flowmeter COPA-XM / MAG-XM ■ Function – The flowrate of liquids, slurries, pastes and sludges can be measured accurately with the electromag netic flowmeter – Minimum conductivity 5 µS/cm – The measurement system consists of a flowmeter |
Original |