Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    M300 LEACH Search Results

    M300 LEACH Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    XTCHH15M300TJEA2P0
    Murata Manufacturing Co Ltd Sine Output Oscillator, 15.3MHz Nom PDF
    XTCJH15M300TJEA3P0
    Murata Manufacturing Co Ltd Sine Output Oscillator, 15.3MHz Nom PDF
    XNCJH15M300TJEA0P0
    Murata Manufacturing Co Ltd Sine Output Oscillator, 15.3MHz Nom PDF
    XNCHH15M300TJEA0P0
    Murata Manufacturing Co Ltd Sine Output Oscillator, 15.3MHz Nom PDF
    PCM3001E
    Texas Instruments Stereo CODEC with line-out (H/W Control) 28-SSOP Visit Texas Instruments Buy

    M300 LEACH Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    RELAIS LEACH

    Abstract: CECC16101-018 Leach International M300
    Contextual Info: F/M300 RELAIS HERMETIQUE 2 RT /10 A HERMETICALLY SEALED RELAY 2 P D T /10 AMPS J - Relais hermétique monostable polarisé Polarized, non latching hermetically sealed relay - Combinaison des contacts - 2 RT Contact arrangement 2 PDT - Alimentation bobine


    OCR Scan
    F/M300 MIL-R-6106 CECC16101-018 CECC16303-801 RELAIS LEACH CECC16101-018 Leach International M300 PDF

    CECC16303-801

    Abstract: Leach relay M83536 CECC16101-018 all zener diode colour code marking N023 silicone R140 m300A m2xx M300 leach M300 relay
    Contextual Info: M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Direct current Meets the requirements of MIL-R-83536/9 and /10 CECC16101-018 Qualified to CECC16303-801


    Original
    PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 CECC16303-801 Leach relay M83536 all zener diode colour code marking N023 silicone R140 m300A m2xx M300 leach M300 relay PDF

    all zener diode colour code

    Abstract: S300-A1A2 MIL-S-12883 S300-A6B3 S300-A8B9 M300 relay S300-A9B9 Leach Relay FD300 diode CECC16101-018
    Contextual Info: M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Direct current Meets the requirements of MIL-R-83536/9 and /10 CECC16101-018 Qualified to CECC16303-801


    Original
    PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 all zener diode colour code S300-A1A2 MIL-S-12883 S300-A6B3 S300-A8B9 M300 relay S300-A9B9 Leach Relay FD300 diode PDF

    s300a

    Abstract: FD300 diode relay m300
    Contextual Info: M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Direct current Meets the requirements of MIL-R-83536/9 and /10 CECC16101-018 Qualified to CECC16303-801


    Original
    PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 s300a FD300 diode relay m300 PDF

    CECC16101-018

    Abstract: CECC16303-801
    Contextual Info: M300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 2 PDT/10 AMP Polarized, non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Direct current Meets the requirements of MIL-R-83536/9 and /10 CECC16101-018 Qualified to CECC16303-801


    Original
    PDT/10 MIL-R-83536/9 CECC16101-018 CECC16303-801 SF300. CECC16303-801 28Vdc: PDF

    Leach relay M83536

    Abstract: T412 RELAY m400 leach MIL-PRF-12883 SC402 Leach relay M400 2SC4012 M400 relay silicone R140 MS27709
    Contextual Info: SC30*, SC40* ENGINEERING DATA SHEET SOCKET FOR 2 OR 4 POLE 10 AMP SNAP AND LOCK SOCKET SERIES DESIGNATION FOR: SERIES M300, M301, M302, M400, M401, M402, T402, T412 DESIGNED TO THE STANDARDS AND REQUIREMENTS OF: MIL-PRF-12883/41 M83536, M83726 and MS27709


    Original
    MIL-PRF-12883/41 M83536, M83726 MS27709 MIL-PRF-12883/40 M83536 MIL-P-46184 ZZ-R-765 MIL-G-45204 SC400 Leach relay M83536 T412 RELAY m400 leach MIL-PRF-12883 SC402 Leach relay M400 2SC4012 M400 relay silicone R140 PDF

    M300 relay

    Abstract: S301-B1A2 M300 leach Leach relay socket MIL-S-12883 S300-A1B3 S301-C6A2 M300-D4A FLR300 S30-1
    Contextual Info: S300, S301, S302 ENGINEERING DATA SHEET RELAY SOCKET 10 AMP BASIC SOCKET SERIES DESIGNATION FOR: Series M300 DC Coil , M301 (DC Coil), M302 (DC Coil), FD300, FLS300, FLR300 GENERAL CHARACTERISTICS Crimp tool contact #22 M 22520/2-01 with turret M 22520/2-14.


    Original
    FD300, FLS300, FLR300 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 S301-B8A8 M300 relay S301-B1A2 M300 leach Leach relay socket MIL-S-12883 S300-A1B3 S301-C6A2 FLR300 S30-1 PDF

    all zener diode colour code

    Abstract: Leach relay M83536 CECC16101-018 CECC16303-801 relay studs m301 m m300d FD300 diode leach relay series E M400 relay
    Contextual Info: M301 ENGINEERING DATA SHEET RELAY - NONLATCH 2 PDT, 10 AMP Non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Alternating current Meets the requirements of MIL-R-83536/11 CECC16101-018 Qualified to CECC16303-801 PRINCIPLE TECHNICAL CHARACTERISTICS


    Original
    MIL-R-83536/11 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 all zener diode colour code Leach relay M83536 CECC16303-801 relay studs m301 m m300d FD300 diode leach relay series E M400 relay PDF

    Relay M302 Reliability

    Abstract: Leach relay M302 Leach relay M83536 3 PDT M302 leach M302 PCB Leach relay M83536 relay m300 Relay leach all zener diode colour code silicone R140
    Contextual Info: M302 ENGINEERING DATA SHEET RELAY - LATCH 2 PDT, 10 AMP Polarized, latching hermetically sealed relay 2 PDT Contact arrangement Meets the requirements of MIL-R-83536/12 and /13 Coil supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS APPLICATION NOTES:


    Original
    MIL-R-83536/12 SC400 SC401-1 SC401-2 SC402 Relay M302 Reliability Leach relay M302 Leach relay M83536 3 PDT M302 leach M302 PCB Leach relay M83536 relay m300 Relay leach all zener diode colour code silicone R140 PDF

    Leach relay M83536 3 PDT

    Abstract: leach relay 250
    Contextual Info: M301 ENGINEERING DATA SHEET RELAY - NONLATCH 2 PDT, 10 AMP Non latching hermetically sealed relay 2 PDT Contact arrangement Coil supply Alternating current Meets the requirements of MIL-R-83536/11 CECC16101-018 Qualified to CECC16303-801 PRINCIPLE TECHNICAL CHARACTERISTICS


    Original
    MIL-R-83536/11 CECC16101-018 CECC16303-801 SC400 SC401-1 SC401-2 SC402 Leach relay M83536 3 PDT leach relay 250 PDF

    Relay M302 Reliability

    Abstract: Leach relay M302 M302 PCB Leach relay M83536
    Contextual Info: M302 ENGINEERING DATA SHEET RELAY - LATCH 2 PDT, 10 AMP Polarized, latching hermetically sealed relay 2 PDT Contact arrangement Meets the requirements of MIL-R-83536/12 and /13 Coil supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS APPLICATION NOTES:


    Original
    MIL-R-83536/12 SC400 SC401-1 SC401-2 SC402 Relay M302 Reliability Leach relay M302 M302 PCB Leach relay M83536 PDF

    FLS300

    Abstract: relay studs m300d relay socket studs M300 relay Leach relay M302 leach relay
    Contextual Info: FLS300 ENGINEERING DATA SHEET TIME DELAY RELAY 1PST SSO Time delay relay (on operate, on release or repeat cycle timer) Fixed or adjustable timing delay Contact arrangement 1 solid state output Power supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS


    Original
    FLS300 25mAmps FLS300 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 S301-B8A8 relay studs m300d relay socket studs M300 relay Leach relay M302 leach relay PDF

    M300 relay

    Abstract: S301-C8A8
    Contextual Info: FLS300 ENGINEERING DATA SHEET TIME DELAY RELAY 1PST SSO Time delay relay (on operate, on release or repeat cycle timer) Fixed or adjustable timing delay Contact arrangement 1 solid state output Power supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS


    Original
    FLS300 25mAmps FLS300 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 S301-B8A8 M300 relay S301-C8A8 PDF

    FLR300

    Contextual Info: FLR300 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 2 AMP Time delay relay on operate, on release or repeat cycle timer Fixed or adjustable timing delay Contact arrangement 2 PDT Power supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at


    Original
    FLR300 /30mV 28VdC 115Vac/60-400Hz M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 FLR300 PDF

    Leach Relay Reliability

    Abstract: TDH-6050 TDH-6051 Leach relay M302
    Contextual Info: TDH-6050/6051 ENGINEERING DATA SHEET ON OPERATE-FIXED PERIOD 2 PDT, 10 AMP FEATURES ● ● ● ● ● ● ● Small size and weight High-reliability design Hermetically sealed High transient immunity Long life Low-power consumption Reverse Polarity Protection


    Original
    TDH-6050/6051 MIL-STD-883, 1x10-8 MIL-T-10727 TDH-6050/51 MIL-PRF-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B Leach Relay Reliability TDH-6050 TDH-6051 Leach relay M302 PDF

    M300 relay

    Abstract: Leach relay high temperature M300 leach Leach International M300
    Contextual Info: TDH-6070/6071 ENGINEERING DATA SHEET ON RELEASE-FIXED PERIOD 2 PDT, 10 AMP FEATURES ● ● ● ● ● ● ● Small size and weight High-reliability design Hermetically sealed High transient immunity Long life Low-power consumption Reverse Polarity Protection


    Original
    TDH-6070/6071 MIL-STD-883, 1x10-8 MIL-T-10727 TDH-6070/71 MIL-R-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B M300 relay Leach relay high temperature M300 leach Leach International M300 PDF

    M400D

    Abstract: Leach Relay 0.5 amp 2 pdt m400 leach MS27709 LRE M300 M401 MIL-C-39029 complete standard M400-D4A M402D Leach relay M400
    Contextual Info: T402 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 2 AMP Time delay relay on operate or on release Fixed or adjustable timing delay Contact arrangement 2 PDT Power supply 28 Vdc PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 2 Amps / 28 Vdc Weight


    Original
    /30mV 28VdC 115Vac/60-400Hz SC400 SC401-1 SC401-2 SC402 M400D Leach Relay 0.5 amp 2 pdt m400 leach MS27709 LRE M300 M401 MIL-C-39029 complete standard M400-D4A M402D Leach relay M400 PDF

    F300 relay

    Abstract: LEACH RELAY M300 relay F300 Leach VFD300 Leach relay FD370 m302 relay Relays FD300 leach relay series E
    Contextual Info: FD300 ENGINEERING DATA SHEET HERMETICALLY SEALED RELAY 1 PDT/10 AMP/56VDC Polarized, non latching hermetically sealed relay 1 PDT NC - NO DB - DM Contact arrangement Coil supply Direct current PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 10 Amps / 56 Vdc


    Original
    FD300 PDT/10 AMP/56VDC SF300CE40E F300 relay LEACH RELAY M300 relay F300 Leach VFD300 Leach relay FD370 m302 relay Relays FD300 leach relay series E PDF

    FLS300

    Abstract: Tai Shing relay date code marking Tai Shing date code marking
    Contextual Info: TDH-6060/6061 ENGINEERING DATA SHEET ON OPERATE-ADJUSTABLE PERIOD 2 PDT, 10 AMP FEATURES ● ● ● ● ● ● ● ● Small size and weight High-reliability design Hermetically sealed High transient immunity Long life Low-power consumption Adjustable Time Delays


    Original
    TDH-6060/6061 MIL-STD-883, MIL-T-10727 TDH-6060/61 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S300-A8B9 FLS300 Tai Shing relay date code marking Tai Shing date code marking PDF

    S301-B1A2

    Abstract: m302 relay Leach Relay
    Contextual Info: TDH-6060/6061 ENGINEERING DATA SHEET ON OPERATE-ADJUSTABLE PERIOD 2 PDT, 10 AMP FEATURES ● ● ● ● ● ● ● ● Small size and weight High-reliability design Hermetically sealed High transient immunity Long life Low-power consumption Adjustable Time Delays


    Original
    TDH-6060/6061 MIL-STD-883, MIL-T-10727 TDH-6060/61 MIL-PRF-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B S300-A8A8 S301-B1A2 m302 relay Leach Relay PDF

    TDH-6070

    Abstract: m300d fd300 M300 relay S30-1
    Contextual Info: TDH-6070/6071 ENGINEERING DATA SHEET ON RELEASE-FIXED PERIOD 2 PDT, 10 AMP FEATURES ● ● ● ● ● ● ● Small size and weight High-reliability design Hermetically sealed High transient immunity Long life Low-power consumption Reverse Polarity Protection


    Original
    TDH-6070/6071 MIL-STD-883, 1x10-8 MIL-T-10727 TDH-6070/71 MIL-R-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B TDH-6070 m300d fd300 M300 relay S30-1 PDF

    TDH-6050

    Abstract: m302 relay S300-A1A2
    Contextual Info: TDH-6050/6051 ENGINEERING DATA SHEET ON OPERATE-FIXED PERIOD 2 PDT, 10 AMP FEATURES ● ● ● ● ● ● ● Small size and weight High-reliability design Hermetically sealed High transient immunity Long life Low-power consumption Reverse Polarity Protection


    Original
    TDH-6050/6051 MIL-STD-883, 1x10-8 MIL-T-10727 TDH-6050/51 MIL-PRF-6106 M300-D4A 301-D4F/-K 301-D4E/-J MIL-S-12883/41B TDH-6050 m302 relay S300-A1A2 PDF

    Leach relay M400 d4a

    Abstract: M400 relay Leach relay M400 S400-A1B3 T412 relay silicone R140 MS27709
    Contextual Info: T412 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 10 AMP Time delay relay on operate or on release Fixed or adjustable timing delay Contact arrangement 2 PDT Power supply 28 Vdc PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 10 Amps / 28 Vdc Weight


    Original
    28Vdc SC400 SC401-1 SC401-2 SC402 Leach relay M400 d4a M400 relay Leach relay M400 S400-A1B3 T412 relay silicone R140 MS27709 PDF

    Leach relay M83536

    Abstract: m400 leach Leach relay M83536 3 PDT M400 relay Leach relay M400 M402 relay Leach relay M402 relay socket studs M400-D4A M300 relay
    Contextual Info: T402 ENGINEERING DATA SHEET TIME DELAY RELAY 2 PDT, 2 AMP Time delay relay on operate or on release Fixed or adjustable timing delay Contact arrangement 2 PDT Power supply 28 Vdc PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 2 Amps / 28 Vdc Weight


    Original
    /30mV 28VdC 115Vac/60-400Hz SC400 SC401-1 SC401-2 SC402 Leach relay M83536 m400 leach Leach relay M83536 3 PDT M400 relay Leach relay M400 M402 relay Leach relay M402 relay socket studs M400-D4A M300 relay PDF