LOOP AN Search Results
LOOP AN Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| SF-QSFPLOOPBK-003 | Amphenol Cables on Demand | Amphenol SF-QSFPLOOPBK-003 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 3dB Attenuation & 1.5W Power Consumption [Copper+Optical Ready] | |||
| SF-QSFPLOOPBK-002 | Amphenol Cables on Demand | Amphenol SF-QSFPLOOPBK-002 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 0dB Attenuation & 0W Power Consumption [Copper+Optical Ready] | |||
| SF-SFPPLOOPBK-0DB | Amphenol Cables on Demand | Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption | |||
| SF-SFPPLOOPBK-003.5 | Amphenol Cables on Demand | Amphenol SF-SFPPLOOPBK-003.5 SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 3.5dB Copper/Optical Cable Emulation | |||
| SF-QSFPLOOPBK-001 | Amphenol Cables on Demand | Amphenol SF-QSFPLOOPBK-001 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 0dB Attenuation & 1.5W Power Consumption [Copper+Optical Ready] |
Documents mentioning LOOP AN
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| max1737 | Maxim > App Notes > POWER-SUPPLY CIRCUITS Keywords: source-current loop, input-current loop, Li+ battery charger Dec 16, 2002 APPLICATION NOTE 1817 Reduce Component Count and Cut Costs by Disabling the MAX1737 Source-Current Loop Abstract: The MAX1737 source-current loop protects low-power sources from being overloaded, however, this sourcecurrent loop can be disabled when using high-power sources. Disabling the source-current loop reduces component |
Original | ||||
| hook | Scotchmate Hook & Loop Fastening System SJ3530 (Hook) & SJ3531 (Loop) Product Data Sheet Updated : July 1999 Supersedes : January 1995 Product Description High Peel Moderate Shear Pressure Sensitive SJ3530 (Hook) SJ3531 (Loop) 3M Scotchmate hook and loop fasteners described |
Original | ||||
| antenna | Antennas for RFIC Transmitter and Receiver Part I : Loop Antennas Efficiency of Small Loop Antenna Small size printed loop antenna is widely used in many applications for RFIC transmitters and receivers. The efficiency of a loop antenna becomes a key issue for the |
Original | ||||
| DC Loop Contactors, Contactor Lugs and Dynamic | DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data DC Loop Contactors, Contactor Lugs and DB Resistors Table of Contents 1370 DC Loop Contactors…3 Catalog Number Explanation…3 |
Original | ||||
| 420i | Loop Powered Isolators 420I R ❚ High accuracy TE YEA ❚ Low voltage drop E The 420I loop powered isolator generates a second isolated loop from an existing loop. Power is derived from the input signal. No external power supply is required. GUARAN ❚ 1kV isolation |
Original | ||||
| 420i | Loop Powered Isolators 420I The 420I loop powered isolator generates a second isolated loop from an existing loop. Power is derived from the input signal. No external power supply is required ■ Low voltage drop ■ High accuracy ■ 1kV isolation ■ High noise immunity |
Original | ||||
| ® www.datel.com DMS-40LCD-4/20S Ultra-Low 2.9V | ® www.datel.com DMS-40LCD-4/20S Ultra-Low 2.9V Loop-Drop 4½ Digit LCD-Display Process Monitor Actual Size Features • Loop-powered, no power supply required! • 2.9V typical loop-drop; 190-Ohm (max.) loop impedance • Dip-switch-selectable range, offset, and |
Original | ||||
| 5 'D A T E L INNOVATION and EXCELLENCE | 5 'D A T E L INNOVATION and EXCELLENCE DMS-40LCD-4/20S 4-20mA Input Loop-Powered, Low Impedance 41/2 Digit, LCD-Display Process Monitor Preliminary Information Features • Loop-powered, no power supply required! • 3.0V typical loop-drop; 190-0hm (max.) loop |
OCR Scan | ||||
| tn8000 | Technical Note TN8000.09 Digital Frequency Locked Loop TN8000.09 Technical Note D.F.L.L Digital Frequency Locked Loop Rev 1 Feb 2006 www.semtech.com 1 Technical Note TN8000.09 Digital Frequency Locked Loop INTRODUCTION A Digital Frequency Locked Loop (DFLL) is an algorithm used to precisely set an RC oscillator frequency using a |
Original | ||||
| Loop-Powered Trip Alarm/ Current Loop Alarm | Loop-Powered Trip Alarm/ Current Loop Alarm ADTECH Analog-Digital Technology, Inc. The Adtech CLA 114 Loop-Powered Trip Alarm accepts 4-20 mA DC input and provides a relay contact output. The CLA loop-powered alarm does not require a separate DC or AC power supply source as conventional alarms |
Original | ||||
| DMS-40LCD-4/20S Series Ultra-Low 2.9V Loop-Drop | DMS-40LCD-4/20S Series Ultra-Low 2.9V Loop-Drop 4½ Digit LCD Display Process Monitor FEATURES N Loop-powered, no power supply required! N 2.9V typical loop-drop; 190-Ohm (max.) loop impedance N Dip-switch-selectable range, offset, and decimal points N Hundreds of different input/readout combinations |
Original | ||||
| Line Loop Tester Available with Field Replaceable | Line Loop Tester Available with Field Replaceable Switches Simpson’s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel “reverse polarity” switch allows |
Original | ||||
| Product catalogue | Electronics | Analogue signal | Product catalogue | Electronics | Analogue signal conditioning | DC/DC passive isolator | Output current loop supply General ordering data Order No. Part designation Version EAN Qty. 8543730000 WAZ5 OLP Output current loop feed, 4…20 mA (current loop) , |
Original | ||||
| Phase-Locked Loop (ALTPLL) Megafunction User | Phase-Locked Loop (ALTPLL) Megafunction User Guide UG-ALTPLL-8.0 © November 2009 Introduction The Phase-Locked Loop (PLL) is a closed-loop frequency-control system that compares the phase difference between the input signal and the output signal of a voltage-controlled oscillator (VCO). The negative feedback loop of the system forces |
Original | ||||
|
|
||||||
| APPLICATION NOTE AN-102 Loop Current Detection | APPLICATION NOTE AN-102 Loop Current Detection for LITELINK AN-102 Loop Current Detection for LITELINK Many DAA applications require loop current detection capability especially in voice communications equipment. Traditionally, an optocoupler device in series with |
Original | ||||
| 8543720000 | Product catalogue | Electronics | Analogue signal conditioning | DC/DC passive isolator | Output current loop supply General ordering data Order No. Part designation Version EAN Qty. 8543720000 WAS5 OLP Output current loop feed, 4…20 mA (current loop) , |
Original | ||||
| an10331 | AN10331 Philips LPC2xxx family phase lock loop Rev. 01 — 1 November 2004 Application note Document information Info Content Keywords LPC2000, Phase Lock Loop Initialization Abstract Application information for the LPC2000 family Phase Lock Loop AN10331 Philips Semiconductors |
Original | ||||
| isl5239 | Open-Loop Power Amplifier Characterization Using the ISL5239 Evaluation Board ® Application Note July 2002 AN1025.0 Aaron Algiere and Randy Raczek Description: This application note presents tools and an example of open-loop power amplifier characterization. An open-loop |
Original | ||||
| fs7140 | FS7140 / FS7145 Programmable Phase-Locked Loop Clock Generator 1.0 Features 2.0 Description • Extremely flexible and low-jitter phase-locked loop (PLL) frequency synthesis • No external loop filter components needed • Configurable CMOS or pseudo-ECL outputs |
Original | ||||