LINEAGE POWER Search Results
LINEAGE POWER Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| SF-SFP28LPB1W-0DB | Amphenol Cables on Demand | Amphenol SF-SFP28LPB1W-0DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 0dB Attenuation & 1W Power Consumption | |||
| SF-SFPPLOOPBK-0DB | Amphenol Cables on Demand | Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption | |||
| SF-SFP28LPB1W-3DB | Amphenol Cables on Demand | Amphenol SF-SFP28LPB1W-3DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 3dB Attenuation & 1W Power Consumption | |||
| SF-100GLB1.5W-6DB | Amphenol Cables on Demand | Amphenol SF-100GLB1.5W-6DB QSFP 100G Loopback Adapter Module for QSFP28 Port Testing - 6dB Attenuation & 1.5W Power Consumption [100-Gigabit Ethernet Ready] | |||
| SF-QSFPLOOPBK-003 | Amphenol Cables on Demand | Amphenol SF-QSFPLOOPBK-003 QSFP+ 40G Loopback Adapter Module for QSFP/QSFP+ Port Testing - 3dB Attenuation & 1.5W Power Consumption [Copper+Optical Ready] |
LINEAGE POWER Price and Stock
Protektive Pak
Protektive Pak LIDS; LINEAGE POWERLIDS |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LIDS; LINEAGE POWER | Bulk | 50 |
|
Get Quote | ||||||
Protektive Pak STORAGE CONTAINER; LINEAGE POWERSTORAGE CONTAINER |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
STORAGE CONTAINER; LINEAGE POWER | Bulk | 50 |
|
Get Quote | ||||||
Documents mentioning LINEAGE POWER
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| j85500s-1 | Lineage® 2000 1800-Ampere, -48-Volt ECS Battery Plant J85500S-1 Product Manual 167-790-061 Comcode 107310286 Issue 6 January 1999 ©Lucent Technologies 1999 Product Manual Select Code 167-790-061 Comcode 107310286 Issue 6 January 1999 Lucent Technologies Lineage® 2000 |
Original | ||||
| 3X improvement over current technologies | 3X improvement over current technologies footprint capacitance cost reliability response Integrated Power Solutions for DSPs & FPGAs Lineage Power has raised the bar for cost-effective high power density for modular high density POL (point-ofload) power DC/DC converters. Lineage’s DC/DC products are well suited to powering designs that include |
Original | ||||
| j85568 | Lineage® 2000 Secondary DC Distribution Bay (Mini-Distribution Bay) J85568E-1 Product Manual Select Code 157-005-102 Comcode 107098840 Issue 6 January 2008 Product Manual J85568E-1 Select Code 157-005-102 Comcode 107098840 Issue 6 January 2008 Lineage® 2000 |
Original | ||||
| h5694772g300-cc | Lineage Power H5694772G300-CC Installation Manual Product Manual Comcode CC848838391-MAN Issue 2 - Draft January 2008 Notice: The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power assumes no responsibility for any errors that may appear |
Original | ||||
| j85500a-2 | Lineage 2000® Battery Plant J85500A-2 Product Manual Select Code 167-790-032 Comcode 108190596 Issue 4 April 1999 © 1999 Lucent Technologies Product Manual Select Code 167-790-032 Comcode 108190596 Issue 4 April 1999 Lineage® 2000 Battery Plant J85500A-2 |
Original | ||||
| j85500a-2 | Lineage 2000® Battery Plant J85500A-2 Product Manual Select Code 167-790-032 Comcode 108190596 Issue 6 January 2008 Product Manual Select Code 167-790-032 Comcode 108190596 Issue 6 January 2008 Lineage® 2000 Battery Plant J85500A-2 Notice: The information, specifications, and procedures in this manual are |
Original | ||||
| j85502c-1 | Lineage® 2000 125-Ampere, 60-Hertz Ferroresonant Rectifier J85502C-1 Product Manual Select Code 169-790-121 Comcode 107044992 Issue 8 July 1999 © 1999 Lucent Technologies Product Manual Select Code 169-790-121 Comcode 107044992 Issue 8 July 1999 Lineage® 2000 |
Original | ||||
| AC Current Interface Unit (CIU) for the | AC Current Interface Unit (CIU) for the Galaxy/Millennium Controller With L60 – L69 Interface Units Operation, Installation and Maintenance Manual WP-93497 Select Code 167-792-103 Comcode 107877870 Issue 7 January 2008 © 2008 Lineage Power All International Rights Reserved |
Original | ||||
| qs941 | QS941A Controller WEB Interface Product Manual Comcode CC848843953-MAN Issue 1 February 2008 Notice: The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power assumes no responsibility for any errors that may appear |
Original | ||||
| fc250s6r51 | Advance Data Sheet April 2008 FC250S6R51 Power Module: dc-dc Converter; 18 Vdc to 36 Vdc Input, 6.5 Vdc Output; 250 W Features n Lineage PowerThe FC250S6R51 Power Module uses advanced, surface-mount technology and delivers highquality, compact, dc-dc conversion at an economical price. |
Original | ||||
| Product Manual J85500T-1 Select Code 167-790-059 | Product Manual J85500T-1 Select Code 167-790-059 Comcode 107300592 Issue 4 October 1998 Lucent Technologies Lineage® 2000 Global Power System Notice: Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. |
Original | ||||
| bdfb | Smart Distribution Monitor – VIM1 Adding Enhancements to BDFB/BDCBB Management The VIM1 Smart Distribution Monitor replaces the digital meters used on Lineage Power Battery Distribution Fuse Bays (BDFB) and Battery Distribution Circuit Breaker Bays (BDCBB). Traditional |
Original | ||||
| qs941a controller | QS941A Controller User Interface Product Manual Select Code 167-792-184 Comcode CC848816612 Issue 3 November 2009 Notice: The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power assumes no responsibility for any errors that may appear |
Original | ||||
| ks-24194 | Data Sheet March 2010 ™ KS-24194 Power Wire The economical KS-24194 non-halogenated copper wire is flame-retardant, low smokeemitting, and recommended for use in 600 V RHH* telecommunication power plant applications. Lineage Power KS-24194 Power Wire is a rugged, |
Original | ||||
|
|
||||||
| wp-93497 | AC Voltage Interface Unit (VIU) for the Galaxy/Millennium Controller With L50 – L55 Interface Units Operation, Installation and Maintenance Manual WP-93497 Select Code 167-792-104 Comcode 107877854 Issue 9 January 2008 © 2008 Lineage Power All International Rights Reserved |
Original | ||||
| solder joint | Application Note August 28, 2009 PDF Name: block_pin_sj_guidelines.pdf Application Guidelines for Non-Isolated Converters AN09-002: Block Pin Solder Joint Guidelines Introduction Lineage Power Austin LynxTM SMT Point of Load power modules utilize block pins as interconnections between the |
Original | ||||
| CCH Series 75 Watt Swithing Power Supply by | CCH Series 75 Watt Swithing Power Supply by Lineage Power Features: ∎ 75 Watt Modular Power Supply ∎ Universal AC Input Range (90-264 VAC) ∎ Optional Power Factor Correction (CCH Models) ∎ Low Profile for 1U High Applications ∎ Meets VDE/FCC Class “B” EMI |
Original | ||||
| millennium | Basic Installation and User’s Guide for the Millennium II Controller J85501P-1 Product Manual Select Code 167-792-181 Comcode 108994645 Issue 3 January 2008 Notice: The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power assumes no responsibility for any errors that may appear |
Original | ||||
| AC Frequency Interface Unit (FIU) for the | AC Frequency Interface Unit (FIU) for the Galaxy/Millennium Controller With L70 and L71 Interface Units Operation, Installation and Maintenance Manual WP-93497 Select Code 167-792-102 Comcode 107877862 Issue 7 January 2008 © 2008 Lineage Power All International Rights Reserved |
Original | ||||
| j85577a-1 | Lineage® 2000 Intelligent Reserve Unit (IRU) J85577A-1 Product Manual Select Code 157-010-100 Comcode 106791205 Issue 5 November 1999 ©1999 Lucent Technologies Product Manual Select Code 157-010-100 Comcode 106791205 Issue 5 November 1999 Lucent Technologies |
Original | ||||
| Application Note April 2009 Compact Power Line | Application Note April 2009 Compact Power Line (CPL) Graphical User Interface (GUI) User Manual Demonstrating the platform’s i2C based protocol The interactive Graphical Interface is designed to demonstrate, and as a tool evaluate, the i2C based communications capabilities of the Lineage CPL power system. The cpgui.exe file can |
Original | ||||
| j85500l-1 | Product Manual J85500L-1 Select Code 167-790-047 Comcode 106979073 Issue 5 January 1998 Lucent Technologies Lineage® 2000 600 Ampere, -48 Volt Global Power System Notice: Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. |
Original | ||||
| galaxy gateway | Galaxy Gateway v3 Web-Based Remote Monitoring and Control Product Manual Select Code 193-104-106 Comcode 108728163 Issue 9 January 2008 Notice: The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power assumes no responsibility for any errors that may appear |
Original | ||||