LINE REACTO Search Results
LINE REACTO Equivalents
Sorry, but there were no results for that search. Please update your search settings or try another search term.
LINE REACTO Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| AV-THLIN2BNCM-005 | Amphenol Cables on Demand | Amphenol AV-THLIN2BNCM-005 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 5ft | |||
| AV-THLIN2BNCM-002.5 | Amphenol Cables on Demand | Amphenol AV-THLIN2BNCM-002.5 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 2.5ft | |||
| AV-THLIN2BNCM-007.5 | Amphenol Cables on Demand | Amphenol AV-THLIN2BNCM-007.5 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 7.5ft | |||
| AV-THLIN2BNCM-015 | Amphenol Cables on Demand | Amphenol AV-THLIN2BNCM-015 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 15ft | |||
| AV-THLIN2BNCM-025 | Amphenol Cables on Demand | Amphenol AV-THLIN2BNCM-025 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 25ft |
Documents mentioning LINE REACTO
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| tpdr series | THREE PHASE DELTA, 600VAC, REACTORS, TPDR SERIES FEATURES AND SPECIFICATIONS SPECIFICATIONS 1.0 HIGHPOT RATING: LINE-TO-GROUND: 2500 VAC LINE-TO-LINE: 2500 VAC 2.0 MAXIMUM LEAKAGE CURRENT, EACH LINE TO GROUND, @ 600VAC, 60Hz: 10 uA max 3.0 PERFORMANCE 0.05 |
Original | ||||
| THREE PHASE DELTA, 600VAC, REACTORS, TPDR SERIES | THREE PHASE DELTA, 600VAC, REACTORS, TPDR SERIES FEATURES AND SPECIFICATIONS SPECIFICATIONS 1.0 HIGHPOT RATING: LINE-TO-GROUND: 2500 VAC LINE -TO-LINE: 2500 VDC 2.0 MAXIMUM LEAKAGE CURRENT, EACH LINE TO GROUND, @ 600VAC, 60Hz: 10 uA max 3.0 PERFORMANCE 0.05 |
Original | ||||
| Enhanced Design Reactors for Line and Load The | Enhanced Design Reactors for Line and Load The MTE RLW REACTOR is MTE’s newest reactor line that, like our RL Reactor product line, keeps equipment running longer by absorbing many of the power line disturbances which otherwise damage or shut down inverters, variable frequency drives (VFDs), variable speed controllers, and other sensitive |
Original | ||||
| Line filters and reactors FN 3400 Three-phase line | Line filters and reactors FN 3400 Three-phase line filter ■ EMC filter for applications with high noise levels Integrated line reactor for low frequency interference and harmonics reduction Compact all-in-one solution for motor drives Significant increase of conducted |
Original | ||||
| Capacitors, Arresters and Harmonic Filters | Capacitors, Arresters and Harmonic Filters Line/Load Reactors—up to 600V…20-2 Line/Load Reactors—Three-phase Reactors…20-4 Matrix Series D Harmonic Filters…20-6 |
Original | ||||
| 1321 | 1321 Power Conditioning Products Technical Data LINE REACTORS REFLECTED WAVE DEVICES ISOLATION TRANSFORMERS COMMON MODE CHOKES DC LINK CHOKES DON’T IGNORE THE COST OF POWER LINE DISTURBANCE 1321 Power Conditioning Products Overview Allen-Bradley reactors help keep equipment running longer by absorbing many of the power line disturbances which can |
Original | ||||
| hsz070245 | Product Specification Bulletin Double Ended Compact 70W 50 Hz Reactor Ballast HSZ070245 IEC 60922: 1997 Input Volts 240 HSZ: Line Current ( Amps ) 0.39 Operating Open Circuit Starting 0.75 0.78 Regulation ±6% Line Volts Lamp Watts ±10% Temperature Ratings |
Original | ||||
| Line reactors RWK 212 Three-phase line reactor | Line reactors RWK 212 Three-phase line reactor for motor drive applications ■ Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents |
Original | ||||
| Line Reactors RWK 212 Three-phase Line Reactor | Line Reactors RWK 212 Three-phase Line Reactor for Motor Drive Applications ■ Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents |
Original | ||||
| reactor | Line filters and reactors RWK 212 Three-phase line reactor for motor drive applications n n n n n n Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents |
Original | ||||
| bonitron | M3345 Line Regen Modules Overvoltage Solutions for AC Drives TYPE-1 M3345 Line Regen Modules are used with AC Drives to eliminate overvoltage faults. Bonitron’s M3345 Line Regen is used in systems with extended braking times or frequent regeneration, and makes any |
Original | ||||
| 1 EMC and Power Quality > RWK 212 Line Reactors | 1 EMC and Power Quality > RWK 212 Line Reactors RWK 212 Three-phase Line Reactor for Motor Drive Applications ■ Provision of 4% impedance Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics |
Original | ||||
| 3-Phase Reactors Line/Load Reactors • Increase | 3-Phase Reactors Line/Load Reactors • Increase Drive System Reliability Filter Power Line Disturbances Reduce Harmonics Reduce Surge Currents Reduce dv/dt Extend Transistor Life Reduce Motor Noise and Temperature Reduce Voltage Doubling Effects |
Original | ||||
| reactor | Seite 1 LR3 40-4/35 Line reactor Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. 4 % Uk Power harmonic damping Increases the service life of consumers Three-phase line and commutation reactor to IEC 61558-2-20, |
Original |