    SF-10GSFPPLCL-000
    Amphenol Cables on Demand Amphenol SF-10GSFPPLCL-000 SFP+ Optical Module - 10GBASE-SR (up to 300m/984') SFP+ Multimode Optical Transceiver Module (Duplex LC Connectors) - Cisco & HP Compatible PDF
    SF-SFP28LPB1W-0DB
    Amphenol Cables on Demand Amphenol SF-SFP28LPB1W-0DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 0dB Attenuation & 1W Power Consumption PDF
    SF-SFPPLOOPBK-0DB
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption PDF
    SF-SFPPLOOPBK-003.5
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-003.5 SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 3.5dB Copper/Optical Cable Emulation PDF
    SF-SFP28LPB1W-3DB
    Amphenol Cables on Demand Amphenol SF-SFP28LPB1W-3DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 3dB Attenuation & 1W Power Consumption PDF

    LEM MODULE HALL EFFECT Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    HEME 1000

    Abstract: lem module 50 lem lta 50p lem heme current 1000 LEM LTA lem current LTA FR7200 LTA51P 50psp1 lem module
    Contextual Info: LEM CURRENT TRANSDUCERS Module LTA 50-P/SP1 Instantaneous Outputs Definition - Principle The LEM type LTA 50-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided


    OCR Scan
    50-p/sp1lta51pheme 1000lem module 50+7lem lta 50plem heme current 1000lem ltalem current ltafr720050psp1lem module PDF

    lem lta 100p

    Abstract: HEME 1000 lem module 50 FR7200 lem module lem current lem heme current 1000 LEM LTA lem 50 p lem+lta+100p/sp1
    Contextual Info: LEM CURRENT TRANSDUCERS Module LTA 100-P/SP1 Instantaneous Outputs Definition - Principle The LEM type LTA 100-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided


    OCR Scan
    100-p/sp1lta101p100-p/spllem lta 100p+9heme 1000lem module 50fr7200lem modulelem currentlem heme current 1000lem ltalem 50 plem+lta+100p/sp1 PDF

    LEM LTA

    Abstract: lem module lta 50pr lem current LTA LTA50PR lem module HEME 1000 lem 50 p 50PR
    Contextual Info: LEM CURRENT TRANSDUCERS Module LTA 50-PR Instantaneous and True RMS Outputs Definition - Principle The LEM type LTA 50-PR is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided


    OCR Scan
    50-prlem ltalem module lta 50prlem current lta+5lta50prlem moduleheme 1000lem 50 p50pr PDF

    lem lt 100 p

    Abstract: lem current lt 100 lem module HEME 1000 lem heme current 1000 lem current LTA
    Contextual Info: LEM CURRENT TRANSDUCERS Module LTA 100-PR Instantaneous and True RMS Outputs Definition - Principle The LEM type LTA 100-PR is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided


    OCR Scan
    100-pr100prlem lt 100 plem current lt 100+4lem moduleheme 1000lem heme current 1000lem current lta PDF

    lem current

    Abstract: lem module lem module 50 LEM LT 200-S lem current LTA LTA200-SP2 LTA200-S code lem hall current transducer lem module hall effect
    Contextual Info: •70 ^^ o S S/ /' oI ' LEM CURRENT TRANSDUCERS MODULE LTA 200-S/SP2 Instantaneous Output Deflnition - Principle The LEM type LTA 200-S/SP2 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation


    OCR Scan
    lta200-slta200-sp2200-s/sp2300amps+103kvrms/50hz/l500mmlem currentlem modulelem module 50lem lt 200-slem current ltacode lemhall current transducerlem module hall effect PDF

    lem lta 50p

    Abstract: LTA50P/SP1 HEME International lem current HEME 1000 lem module 50 Lta100 lem module noryl grade 50P/SP1
    Contextual Info: LEM CURRENT TRANSDUCERS Module LTA 50P/SP1 ! cj ~7~ S Instantaneous Outputs . 03, Definition - Principle The LEM type LTA50P/SP1 is a transducer employing the Hall Effect to measure D.C. and complex waveform A.C. currents in a non invasive manner. Galvanic isolation is provided between the primary (measured) and the analogue


    OCR Scan
    50p/sp1lta50p/sp1lta100/sp1100khz+9v0-150lem lta 50pheme internationallem currentheme 1000lem module 50lta100lem modulenoryl grade PDF

    HEME 1000

    Abstract: lem module LTA100PR lem current HEME International lem module 50 microsecond
    Contextual Info: LEM HEME LEM CURRENT TRANSDUCERS Module LTA100PR Instantaneous and True RMS Outputs . Definition - Principle T h e L EM type LTA100PR is a transducer em ploying the Hall Effect to m easure D.C. and com plex w aveform A.C. currents in a n o n invasive m anner. Galvanic isolation is provided betw een the prim ary (m easured ) an d the analogue


    OCR Scan
    lta100prrms/50hz/lheme 1000lem module+4lem currentheme internationallem module 50microsecond PDF

    lem lta 100p

    Abstract: HEME International lta100p/sp4 LTA100P/SP1 lem current HEME 1000 lem module 100A noryl grade LTA100/SP1 lta100
    Contextual Info: HEMEL I, InternationalÊÊÊ LEM CURRENT TRANSDUCERS Module LTA 100P/SP1 lo7- Instantaneous Outputs . Definition - Principle T he L EM type LTAIOOP/SPI is a transducer em ploying the Hall Effect to m easure D C and com plex w aveform A C currents in a non invasive m a n n e r Galvanic isolation is provided betw een the primary (m easured) and the analogue


    OCR Scan
    lta100p/sp1lta100/sp1v0-150lem lta 100p+7heme internationallta100p/sp4lem currentheme 1000lem module 100anoryl gradelta100 PDF

    lem HA

    Abstract: ha500sr lem ha 400 lem module ha HA500-SR lem module LEM transducer lem current 400sr HA400S
    Contextual Info: LEM CURRENT TRANSDUCERS M o d u les H A 400-SR U , H A 400-SR I H A 500-SR U , H A 500-SR I T ru e RM S O u tp u ts Definition - Principle The LEM type HA400SR and HA500SR are transducers employing the Hall Effect to measure D.C. and complex waveform A.C. currents in a non invasive manner. Galvanic isolation is provided between the primary (measured) and


    OCR Scan
    400-sr500-srha400srha500sr+10ha400-srha500-srlem halem ha 400lem module halem modulelem transducerlem current400srha400s PDF

    HA400S

    Abstract: lem ha400-s lem HA lem module HA500S HA400-S LEM transducer Current transducer HA 400 SU
    Contextual Info: LEM CURRENT TRANSDUCERS M odu les H A 400-S B , H A 400-S U , H A 400-S I H A 500-S B , H A 500-S U , H A 500-S I In sta n ta n e o u s O u tp u ts Definition - Principle The LEM type HA400S and HA500S are transducers employing the Hall Effect to measure D.C. and complex


    OCR Scan
    400-s500-sha400sha500s+7ha400-sha500-slem ha400-slem halem modulelem transducercurrent transducer ha 400 su PDF

    HA300SR

    Abstract: HA200SR lem current lem HA 200-SRU lem module hall effect lem ha 400 300-SR lem module 200-SR
    Contextual Info: LEM CURRENT TRANSDUCERS M o d u les H A 200-SR U , H A 200-SR I H A 300-SR U , H A 300-SR I T ru e RM S O u tp u ts Definition - Principie The LEM type HA200SR and HA300SR are transducers employing the Hall Effect to measure D.C. and complex waveform A.C. currents in a non invasive manner. Galvanic isolation is provided between the primary (measured) and


    OCR Scan
    200-sr300-srha200srha300sr+8ha200-srha300-srlem currentlem ha200-srulem module hall effectlem ha 400lem module PDF

    Contextual Info: AUTOMOTIVE CURRENT TRANSDUCER HAB 100-S/SP1 Principle of HAB xxx-S Family Introduction The HAB Family is best suited for DC, AC or pulsed currents measurement in high power and low voltage automotive applications. It’s contains galvanic isolation between the primary


    Original
    100-s/sp1hab100-s/sp1 PDF

    Contextual Info: AUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5 Principle of HAB xxx-S Family The HAB Family is best suited for DC, AC or pulsed currents measurement in high power and low voltage automotive applications. It’s contains galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit).


    Original
    60-s/sp5 PDF

    Contextual Info: Current Transducer LT 2005-S/SP3 IPN = 1100 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). 0648 Features Electrical data IPN


    Original
    2005-s/sp3 PDF

    lem sensor

    Contextual Info: AUTOMOTIVE CURRENT TRANSDUCER HAB 80-S Principle of HAB xxx-S Family The HAB Family is best suited for DC, AC or pulsed-current measurements in high-power and low-voltage automotive applications. It’s contains galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit).


    Original
    lem sensor PDF

    Contextual Info: AUTOMOTIVE CURRENT TRANSDUCER HABT 100-V/SP1 Principle of HABT Family Introduction The HABT 100-V/SP1 current transducer is attached on the battery cable or bus-bar of a vehicle. It provides to a controller (ECU) the actual value of current lowing in the cable and


    Original
    00-v/sp112m/s PDF

    Contextual Info: AUTOMOTIVE CURRENT TRANSDUCER HABT 100-V Principle of HABT Family Introduction The HABT 100-V current transducer is attached on the battery cable or bus-bar of a vehicle. It provides to a controller (ECU) the actual value of current lowing in the cable and


    Original
    volt20312m/s PDF

    JIS Z 2371

    Contextual Info: AUTOMOTIVE CURRENT TRANSDUCER HABT 120-V Principle of HABT Family Introduction The HABT 120-V current transducer is attached on the battery cable or bus-bar of a vehicle. It provides to a controller (ECU) the actual value of current lowing in the cable and


    Original
    volt20312m/sjis z 2371 PDF

    Contextual Info: Current Transducer LT 4000-S/SP34 For the electronic measurement of currents: DC, AC, pulsed., with galvanic isolation between the primary circuit and the secondary circuit. IPN = 4000 A 0651 Features Electrical data Primary nominal current rms Primary current, measuring range


    Original
    4000-s/sp34curr4000-s/sp3415september2011/version PDF

    Contextual Info: IPN Current Transducer LT 2005-T/SP2 = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data Features IPN IPM


    Original
    2005-t/sp294-v0 PDF

    Contextual Info: IPN Current Transducer LT 2005-S/SP20 = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IPM RM Primary nominal current rms


    Original
    2005-s/sp20 PDF

    Contextual Info: Current Transducer LT 2005-S/SP24 IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IPM Primary nominal current rms


    Original
    2005-s/sp24 PDF

    Contextual Info: IPN Current Transducer LT 2005-T/SP8 = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Features Electrical data • Closed loop (compensated) current


    Original
    2005-t/sp894-v0 PDF

    Contextual Info: Current Transducer LF 2005-S/SP4 IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Features Electrical data IPN IPM


    Original
    2005-s/sp4 PDF