Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LEM MODULE 50 Search Results

    LEM MODULE 50 Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    LBUA5QJ2AB-828EVB
    Murata Manufacturing Co Ltd QORVO UWB MODULE EVALUATION KIT PDF
    LBUA5QJ2AB-828
    Murata Manufacturing Co Ltd QORVO UWB MODULE PDF
    LBAA0QB1SJ-295
    Murata Manufacturing Co Ltd SX1262 MODULE WITH OPEN MCU PDF
    MYC0409-NA-EVM
    Murata Manufacturing Co Ltd 72W, Charge Pump Module, non-isolated DC/DC Converter, Evaluation board PDF
    MHM411-21
    Murata Manufacturing Co Ltd Ionizer Module, 100-120VAC-input, Negative Ion PDF

    LEM MODULE 50 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    HEME 1000

    Abstract: lem module 50 lem lta 50p lem heme current 1000 LEM LTA lem current LTA FR7200 LTA51P 50psp1 lem module
    Contextual Info: LEM CURRENT TRANSDUCERS Module LTA 50-P/SP1 Instantaneous Outputs Definition - Principle The LEM type LTA 50-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided


    OCR Scan
    50-P/SP1 50-P/SP1 LTA51P LTA51P HEME 1000 lem module 50 lem lta 50p lem heme current 1000 LEM LTA lem current LTA FR7200 50psp1 lem module PDF

    LEM LTA

    Abstract: lem module lta 50pr lem current LTA LTA50PR lem module HEME 1000 lem 50 p 50PR
    Contextual Info: LEM CURRENT TRANSDUCERS Module LTA 50-PR Instantaneous and True RMS Outputs Definition - Principle The LEM type LTA 50-PR is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided


    OCR Scan
    50-PR 50-PR LEM LTA lem module lta 50pr lem current LTA LTA50PR lem module HEME 1000 lem 50 p 50PR PDF

    lem lta 100p

    Abstract: HEME 1000 lem module 50 FR7200 lem module lem current lem heme current 1000 LEM LTA lem 50 p lem+lta+100p/sp1
    Contextual Info: LEM CURRENT TRANSDUCERS Module LTA 100-P/SP1 Instantaneous Outputs Definition - Principle The LEM type LTA 100-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided


    OCR Scan
    100-P/SP1 100-P/SP1 LTA101P 100-P/SPl lem lta 100p HEME 1000 lem module 50 FR7200 lem module lem current lem heme current 1000 LEM LTA lem 50 p lem+lta+100p/sp1 PDF

    lem lt 100 p

    Abstract: lem current lt 100 lem module HEME 1000 lem heme current 1000 lem current LTA
    Contextual Info: LEM CURRENT TRANSDUCERS Module LTA 100-PR Instantaneous and True RMS Outputs Definition - Principle The LEM type LTA 100-PR is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided


    OCR Scan
    100-PR 100-PR 100PR lem lt 100 p lem current lt 100 lem module HEME 1000 lem heme current 1000 lem current LTA PDF

    lem current

    Abstract: lem module lem module 50 LEM LT 200-S lem current LTA LTA200-SP2 LTA200-S code lem hall current transducer lem module hall effect
    Contextual Info: •70 ^^ o S S/ /' oI ' LEM CURRENT TRANSDUCERS MODULE LTA 200-S/SP2 Instantaneous Output Deflnition - Principle The LEM type LTA 200-S/SP2 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation


    OCR Scan
    LTA200-S LTA200-SP2 200-S/SP2 300Amps 3kVrms/50Hz/l 500mm. 200-S/SP2 lem current lem module lem module 50 LEM LT 200-S lem current LTA LTA200-SP2 code lem hall current transducer lem module hall effect PDF

    IQ226075

    Abstract: LF101 cte table
    Contextual Info: POWEREX W 3=iE D I NC IM E ilE 7S=î4b21 GDOM'ill S H P R X IQ226075 X Powerex, Inc., Hlllls Street, Youngwood, Pennsylvania 15697 412 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 LeM ans, France (43)41.14.14 Chopper IGBTMOD Power Module


    OCR Scan
    IQ226075 Amperes/600 BP107, 75Amperes/600Volts LF101 cte table PDF

    lem current

    Abstract: LEM LTA HEME International 50PR lem module 50 LTA50PR lem heme current 1000 HEME 1000
    Contextual Info: I to - c o i L E M HEME P IO N E E R IN G P O W E R E L E C T R O N IC S LEM CURRENT TRANSDUCERS Module LTA 50PR Instantaneous and True RMS Outputs . Definition - Principle T h e L EM type LTA50PR is a transducer em ploying the Hall Fffect to m e asu re D.C a n d c o m plex wavefor m A.C


    OCR Scan
    LTA50PR RMS/50Hz/l lem current LEM LTA HEME International 50PR lem module 50 lem heme current 1000 HEME 1000 PDF

    lem HA

    Abstract: ha500sr lem ha 400 lem module ha HA500-SR lem module LEM transducer lem current 400sr HA400S
    Contextual Info: LEM CURRENT TRANSDUCERS M o d u les H A 400-SR U , H A 400-SR I H A 500-SR U , H A 500-SR I T ru e RM S O u tp u ts Definition - Principle The LEM type HA400SR and HA500SR are transducers employing the Hall Effect to measure D.C. and complex waveform A.C. currents in a non invasive manner. Galvanic isolation is provided between the primary (measured) and


    OCR Scan
    400-SR 500-SR HA400SR HA500SR HA400-SR HA500-SR HA500SR lem HA lem ha 400 lem module ha HA500-SR lem module LEM transducer lem current 400sr HA400S PDF

    HA400S

    Abstract: lem ha400-s lem HA lem module HA500S HA400-S LEM transducer Current transducer HA 400 SU
    Contextual Info: LEM CURRENT TRANSDUCERS M odu les H A 400-S B , H A 400-S U , H A 400-S I H A 500-S B , H A 500-S U , H A 500-S I In sta n ta n e o u s O u tp u ts Definition - Principle The LEM type HA400S and HA500S are transducers employing the Hall Effect to measure D.C. and complex


    OCR Scan
    400-S 500-S HA400S HA500S HA400-S HA500-S lem ha400-s lem HA lem module HA400-S LEM transducer Current transducer HA 400 SU PDF

    current transducer la 55-tp

    Contextual Info: Current Transducer LA 55-TP IPN = 50 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). 16016 Electrical data IPN IP RM Primary nominal r.m.s. current


    Original
    55-TP current transducer la 55-tp PDF

    Molex 5045-04 ag

    Abstract: lem module 50 Molex 5045-04 LEM transducer LA 400 lem module 0634 ups over smps advantages LEM module application note Current Transducer lem LEM transducer
    Contextual Info: Current Transducer LA 50-S/SP1 IPN = 50 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). 0634 Electrical data Features IPN IP


    Original
    50-S/SP1 5045-04/AG Molex 5045-04 ag lem module 50 Molex 5045-04 LEM transducer LA 400 lem module 0634 ups over smps advantages LEM module application note Current Transducer lem LEM transducer PDF

    has 50 lem

    Abstract: HAS 50-S 5045-04A has lem lem module 100-S
    Contextual Info: Current Transducer HAS 50 . 600-S For the electronic measurement of currents: DC, AC, pulsed., with galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). IPN = 50 . 600 A Electrical data Type Primary nominal Primary current, RoHS since


    Original
    600-S 100-S 200-S 300-S 400-S 500-S 200MHz 700MHz. has 50 lem HAS 50-S 5045-04A has lem lem module 100-S PDF

    High Voltage Busbar

    Abstract: has lem lem module 060613
    Contextual Info: Current Transducer LTC 600-S IPN = 500 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IP ÎP RM Primary nominal r.m.s. current


    Original
    600-S High Voltage Busbar has lem lem module 060613 PDF

    lem 400-P

    Abstract: has lem 100-P lem module 50-P ipm ups design
    Contextual Info: Current Transducer HAS 50 . 600-P For the electronic measurement of currents: DC, AC, pulsed., with galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). IPN = 50 . 600 A Electrical data Type Primary nominal Primary current, RoHS since


    Original
    600-P 100-P 200-P 300-P 400-P 500-P lem 400-P has lem 100-P lem module 50-P ipm ups design PDF

    lem module 50

    Abstract: motors used in transducer
    Contextual Info: IPN = 5 . 50 A AC Current transducer AT-B10 Split-core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). RMS 0-10V voltage output. Electrical data


    Original
    AT-B10 0-10VDC lem module 50 motors used in transducer PDF

    ATB5

    Contextual Info: AC Current transducer AT-B5 IPN = 5 . 50 A Split-core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). RMS 0-5V voltage output. Electrical data


    Original
    PDF

    Contextual Info: IPN = 500 A Current transducer LF 510-S For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features Standards ●● Bipolar and insulated current measurement up to 0.8 kA ●● EN 50178: 1997


    Original
    510-S 4May2015/Version PDF

    AT-B420L

    Contextual Info: AC Current transducer AT-B420L IPN = 5 . 50 A Split-core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). RMS 4-20mA current output. Electrical data


    Original
    AT-B420L 4-20mA B420L 24VDC AT-B420L PDF

    50-SD

    Abstract: LEM current transformer
    Contextual Info: AC Current transformer TT 50-SD IPN = 50 A Split core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). Electrical data IPN IOUT VSZ ÎP Primary nominal current rms


    Original
    50-SD 25ohm 50ohm 100ohm TT50-SD 15ohm 50-SD LEM current transformer PDF

    Contextual Info: Current Transducer HTB 50 . 400 - P and HTB 50 . 100 - TP For the electronic measurement of currents: DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). IPN = 50 . 400 A


    Original
    50-TP1) 100-P, 100-TP1) 150-P 200-P 300-P 400-P 400-P 100-TP PDF

    ELECTRICAL CALCULATION FOR TRANSFORMER

    Abstract: 5LEM LEM split core transducer
    Contextual Info: AC Current transformer TT 50-SD IPN = 50 A Split core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). Electrical data IPN IOUT VSZ ÎP Primary nominal current rms


    Original
    50-SD 25ohm 50ohm 100ohm TT50-SD 15ohm ELECTRICAL CALCULATION FOR TRANSFORMER 5LEM LEM split core transducer PDF

    lem LA 55-P application

    Abstract: LEM module LA 50-P
    Contextual Info: Current Transducer LA 55-P For the electronic measurement of currents: DC, AC, pulsed., with galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). IPN = 50 A 16019 Electrical data IPN Primary nominal current rms


    Original
    PDF

    LF 505-S

    Abstract: Molex 5045-03
    Contextual Info: IPN Current Transducer LF 505-S = 500 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). 16137 Electrical data I PN IP RM Primary nominal rms current


    Original
    505-S 5045-03/A LF 505-S Molex 5045-03 PDF

    LEM Hais 100-P

    Abstract: LEM Hais 50-P HAIS 100-P LEM ups over smps advantages lem 400-P 100-P code lem lem module 100A
    Contextual Info: Current Transducer HAIS 50.400-P Current Transducer HAIS 50.400-P and and HAIS 50.100-TP HAIS 50.100-TP = 50 . 400 A IIPN PN = 50 . 400 A For the For electronic measurement of ofcurrents: DC,AC, AC,pulsed, pulsed., the electronic measurement currents : DC,


    Original
    400-P 100-TP LEM Hais 100-P LEM Hais 50-P HAIS 100-P LEM ups over smps advantages lem 400-P 100-P code lem lem module 100A PDF