    APP-20

    Abstract: long range locators diagram RXTUG 2H type of microprocessor in printer APP20 X101 power cable fault locator power transformers fault ranza printer high voltage transformer
    Contextual Info: ASEA RELAYS INFORMATION From/Date RFR, D ecem ber 1984 Edition 2 RK 881-300 E Reg 7631 Page 1 F a u lt lo c a to r ty p e RANZA A fa u lt lo c ato r is a co m p lem en t to th e transm ission line p ro te c tiv e relay s. ASEA's fa u lt lo c a to r ty p e RANZA, which is required in one


    OCR Scan
    rgke070app-20long range locators diagramrxtug 2h+7type of microprocessor in printerapp20x101power cable fault locatorpower transformers faultranzaprinter high voltage transformer PDF

    Lem LT 300

    Abstract: Lem LT 300 - t lem current lt 100 LT 300-T/SP13 lem lt 100 300-T/SP13
    Contextual Info: Current Transducer LT 300-T/SP13 IPN = 300 A DC For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IP RM Features


    Original
    300-t/sp13lem lt 300lem lt 300 - tlem current lt 100+2lt 300-t/sp13lem lt 100 PDF

    lem lt 2000

    Abstract: M66244FP
    Contextual Info: PRELIMINARY DATA SHEET MITSUBISHI <DIGITAL ASSP> M66244FP June 1998 Ver.8.0.0 High Speed Monolithic Pulse Width Modulator NOTE:This is not final specification. Some parametric limits are subject to change DESCRIPTION The M66244FP is a high-speed digitally programmable pulse width modulator PWM which


    Original
    m66244fp72mhz45mhz16bit+211bitlem lt 2000 PDF

    Contextual Info: Current Transducer LT 1005-T/SP3 IPN = 1000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). 16149 Electrical data IPN IP RM


    Original
    1005-t/sp3 PDF

    Contextual Info: Current Transducer LT 4000-S/SP34 For the electronic measurement of currents: DC, AC, pulsed., with galvanic isolation between the primary circuit and the secondary circuit. IPN = 4000 A 0651 Features Electrical data Primary nominal current rms Primary current, measuring range


    Original
    4000-s/sp34curr4000-s/sp3415september2011/version PDF

    Contextual Info: IPN Current Transducer LT 2005-T/SP2 = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data Features IPN IPM


    Original
    2005-t/sp294-v0 PDF

    Contextual Info: IPN Current Transducer LT 2005-S/SP20 = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IPM RM Primary nominal current rms


    Original
    2005-s/sp20 PDF

    Contextual Info: Current Transducer LT 2005-S/SP24 IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IPM Primary nominal current rms


    Original
    2005-s/sp24 PDF

    Contextual Info: IPN Current Transducer LT 2005-T/SP8 = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Features Electrical data • Closed loop (compensated) current


    Original
    2005-t/sp894-v0 PDF

    lem lt 100 p

    Abstract: N24-N2 Lem LT 80 p lem current lt 100 LG jtag
    Contextual Info: P R E L IM IN A R Y D A T A S H E E T M it s u b is h i < d ig it a l a s s p > M66244FP June 1998 Ver.8.0.0 High Speed Monolithic Pulse Width Modulator NO TE:This is not final specification. Some parametric limits are subject to change DESCRIPTION The M66244FP is a high-speed digitally programmable pulse width modulator PWM which


    OCR Scan
    m66244fp72mhz45mhzlem lt 100 p+4n24-n2lem lt 80 plem current lt 100lg jtag PDF

    Contextual Info: Current Transducer LT 2005-T/SP22 IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IPM RM Features


    Original
    2005-t/sp22 PDF

    Contextual Info: IPN Current Transducer LT 2005-S/SP12 = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). 0646 Electrical data IPN IPM RM


    Original
    2005-s/sp12 PDF

    Contextual Info: Current Transducer LT 2005-T/SP6 IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IPM RM Features


    Original
    2005-t/sp6 PDF

    lem lt 100-p

    Contextual Info: Current Transducer LT 2005-S/SP6 IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IPM Features


    Original
    2005-s/sp6lem lt 100-p PDF

    Contextual Info: P R E U M tfM A R Y D A T A S H E E T M it s u b is h i < d ig it a l a s s p > M66244FP June 1998 Ver.8.0.0 High Speed M onolithic Pulse W idth Modulator NOTE:This is not final specification. Some parametric limits are subject to change DESCRIPTION The M66244FP is a high-speed digitally programmable pulse width modulator PWM which


    OCR Scan
    m66244fp72mhz45mhz16bit+1d02b411 PDF

    Contextual Info: Current Transducer RA 2000-S/SP1 IP DC < 3000 A For the measurement of alternating components in a determined bandwidth, contained in a continuous primary current up to 3000 A. Electrical data IP DC VOUT Continuous primary current Output voltage instantaneous


    Original
    2000-s/sp194-ction PDF

    Contextual Info: Current Transducer RA 1005-S IPDC < 1000 A For the measurement of alternating components in a determined bandwidth, contained in a continuous primary current up to 1000 A. Electrical data IP DC M Continuous primary current Transfer ratio VOUT Output voltage instantaneous


    Original
    1005-s PDF

    BP107

    Abstract: C380 C380MX500
    Contextual Info: POWEREX f O "ÖS IN C M E K H m T| 7214b51 C380 Í P o w e rex , Inc. W ills S treet, Y oungw ood, P enn sylvan ia 15697 412 9 2 5 -7 2 7 2 P o w e re x E urope, S.A., 42 8 A ve. G. D urand, BP107, 72003 LeM ans, F ra n c e (4 3 ) 72.75,15 0002^54 X500 a


    OCR Scan
    7214b51t-25-19bp107c380+1c380mx500 PDF

    thyristors 5000 volt 3000 amperes

    Abstract: Lem LT 300 - t CODE 1AM powerex T9G T9G0 Lem LT 300
    Contextual Info: P0U1EREX INC m u o D5 a x DE 1 7 5 c14bEl QD03DSb S _ T - 2 S *2 tf T9G0 Pow erex, Inc. Hlllls Street, Youngwood, Pennsylvania 15897 412 925 -7 2 7 2 Phase Control SCR P o w e re x Europe, S.A., 4 28 Ave. Q. Durand, BP107, 72003 LeM ana, France (43 ) 72.75.1S


    OCR Scan
    14belqd03dsbbp107amperes/2400-4000+7ax/10thyristors 5000 volt 3000 ampereslem lt 300 - tcode 1ampowerex t9gt9g0lem lt 300 PDF

    lem current lt 100

    Abstract: lem current lt 2005-s lem lt 2000 LEM LT 2005-s LEM Components SMPS IC 2005
    Contextual Info: Current Transducer LT 2005-S IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current


    Original
    2005-slem current lt 100lem current lt 2005-slem lt 2000+3lem lt 2005-slem componentssmps ic 2005 PDF

    lem current lt 2000-s

    Abstract: lem lt 2000 lem current lt 100 LT-2000-S 2000-S AC voltage transducer lem LT LT 2000-S
    Contextual Info: Current Transducer LT 2000-S IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current


    Original
    2000-s400nallem current lt 2000-slem lt 2000+5lem current lt 100lt-2000-sac voltage transducerlem ltlt 2000-s PDF

    Contextual Info: Current Transducer LT 1005-S/SP3 IPN = 1000 A For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). 0629 Electrical data IPN IP RM


    Original
    1005-s/sp3 PDF

    LT308-S7

    Abstract: LEM LT 308 S7 Lem LT 300 - t Lem LT 300 308-S7 LEM LT 308 lem lt 2000 LT308-S
    Contextual Info: 电 流 传 感 器 LT 308-S7 IPN = 原边和副边之间是绝缘的 ,用于测量直流 300 A 交流和脉冲电流 。 电参数 性能 原边额定有效值电流 原边电流, 测量范围 测量电阻 @ IPN IP RM with ± 12 V with ± 15 V 精度


    Original
    308-s794-v0lt308-s7lem lt 308 s7+5lem lt 300 - tlem lt 300lem lt 308lem lt 2000lt308-s PDF

    LEM LT 308

    Abstract: Lem LT 300 LT308-T7 Lem LT 500 t7 308
    Contextual Info: 电流传感器 LT 308-T7 IPN = 原边和副边之间是绝缘的,用于测量直流 300 A 交流和脉冲电流 。 电参数 性能 原边额定有效值电流 原边电流, 测量范围 测量电阻 @ IPN IP RM with ± 12 V with ± 15 V 精度 L • 应用霍尔原理的闭环(补偿)电流传感


    Original