Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LEM LT 100 Search Results

    Documents mentioning LEM LT 100

    Document Partial File Text Tags Type PDF
    ranza
    ASEA RELAYS INFORMATION From/Date RFR, D ecem ber 1984 Edition 2 RK 881-300 E Reg 7631 Page 1 F a u lt lo c a to r ty p e RANZA A fa u lt lo c ato r is a co m p lem en t to th e transm ission line p ro te c tiv e relay s. ASEA's fa u lt lo c a to r ty p e RANZA, which is required in one
    OCR Scan PDF
    î/UD>NPN=«Êi0Kh5>2?^ (PCT755Î) 2 s c 1628 SILICON
    î/UD>NPN=«Êi0Kh5>2?^ (PCT755Î) 2 s c 1628 SILICON NPN TRIPLE DIFFUSED TRANSISTOR (PCT PROCESS h O • H i g h V o lt a g e  itŒ T ^- : a \s 9 D river V q eo = ^ (il Stage A m p l i f ie r 150V 5 W : W S S A 8 1 8 ¿^> - 7' 5 ^ . / — s'm p lem en ta r 7 to
    OCR Scan PDF
    HITACHI 2S B 1109, 2 S B 1110 SILIC O N PNP
    HITACHI 2S B 1109, 2 S B 1110 SILIC O N PNP EPITAXIA L LOW F R E Q U E N C Y HIGH V O LT A G E A M PLIFIER C O M P LEM EN TA R Y PAIR WITH 2SD1609 AND 2SD1610 A 1 i. îimiHff CoHcctor ■ 3 ! if % A3 in n!ir»i { J E D E C TO-126 MOO.) I A B S O L U T E MAXIMUM R A T IN G S CTa=25X)
    OCR Scan PDF
    Current Transducer LT 100-S/SP30 IPN = 100 A For
    Current Transducer LT 100-S/SP30 IPN = 100 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). 16240 Electrical data IPN IP RM
    Original PDF
    lt 1000-ti
    Current Transducer LT 1000-TI IPN = 1000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF
    lt 1000-si
    IPN Current Transducer LT 1000-SI = 1000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF
    LEM CURRENT TRANSDUCERS Module LTA 100-PR
    LEM CURRENT TRANSDUCERS Module LTA 100-PR (Instantaneous and True RMS Outputs) Definition - Principle The LEM type LTA 100-PR is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided
    OCR Scan PDF
    10000-s
    Current Transducer LT 10000-S IPN = 10000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF
    lt 1000-si
    Current Transducer LT 1000-SI IPN = 1000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF
    Current Transducer LT 10000-S IPN = 10000 A For
    Current Transducer LT 10000-S IPN = 10000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF
    1005-s
    Current Transducer LT 1005-S IPN = 1000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF
    m66244fp
    PRELIMINARY DATA SHEET MITSUBISHI <DIGITAL ASSP> M66244FP June 1998 Ver.8.0.0 High Speed Monolithic Pulse Width Modulator NOTE:This is not final specification. Some parametric limits are subject to change DESCRIPTION The M66244FP is a high-speed digitally programmable pulse width modulator (PWM) which
    Original PDF
    P R E L IM IN A R Y D A T A S H E E T M it s u b
    P R E L IM IN A R Y D A T A S H E E T M it s u b is h i < d ig it a l a s s p > M66244FP June 1998 Ver.8.0.0 High Speed Monolithic Pulse Width Modulator NO TE:This is not final specification. Some parametric limits are subject to change DESCRIPTION The M66244FP is a high-speed digitally programmable pulse width modulator (PWM) which
    OCR Scan PDF
    c380
    POWEREX f O "ÖS IN C M E K H m T| 7214b51 C380 Í P o w e rex , Inc. W ills S treet, Y oungw ood, P enn sylvan ia 15697 (412) 9 2 5 -7 2 7 2 P o w e re x E urope, S.A., 42 8 A ve. G. D urand, BP107, 72003 LeM ans, F ra n c e (4 3 ) 72.75,15 0002^54 X500 a
    OCR Scan PDF
    电 流 传 感 器 LT 108-S7 IPN = 原边和副边之间是绝缘的 ,用于测量直流 100
    电 流 传 感 器 LT 108-S7 IPN = 原边和副边之间是绝缘的 ,用于测量直流 100 A 交流和脉冲电流 。 电参数 性能 原边额定有效值电流 原边电流, 测量范围 测量电阻 @ IPN IP RM 100 0 .. ± 150 A A 器 RM min
    Original PDF
    t9g0
    P0U1EREX INC m u o D5 a x DE 1 7 5 c14bEl QD03DSb S __________________________ T - 2 S *2 tf T9G0 Pow erex, Inc. Hlllls Street, Youngwood, Pennsylvania 15897 (412) 925 -7 2 7 2 Phase Control SCR P o w e re x Europe, S.A., 4 28 Ave. Q. Durand, BP107, 72003 LeM ana, France (43 ) 72.75.1S
    OCR Scan PDF
    Current Transducer LT 4000-T IPN = 4000 A For the
    Current Transducer LT 4000-T IPN = 4000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF
    电 流 传 感 器 LT 108-T7 IPN = 原边和副边之间是绝缘的 ,用于测量直流 100
    电 流 传 感 器 LT 108-T7 IPN = 原边和副边之间是绝缘的 ,用于测量直流 100 A 交流和脉冲电流 。 电参数 性能 原边额定有效值电流 原边电流, 测量范围 测量电阻 @ IPN IP RM 100 0 .. ± 150 A A 器 RM min
    Original PDF
    Current Transducer LT 2005-S IPN = 2000 A For the
    Current Transducer LT 2005-S IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF
    lt 2000-s
    Current Transducer LT 2000-S IPN = 2000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF
    Current Transducer LT 4000-S IPN = 4000 A For the
    Current Transducer LT 4000-S IPN = 4000 A For the electronic measurement of currents : DC, AC, pulsed…, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current
    Original PDF