LEM HALL EFFEC Search Results
LEM HALL EFFEC Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TMAG5110A2AQDBVR | Texas Instruments | 2-dimensional, dual-channel, high-sensitivity, Hall-effect latch |
|
|
|
| DRV5013BCQLPG | Texas Instruments | 2.5V to 38V Hall Effect Latch 3-TO-92 -40 to 125 |
|
|
|
| DRV5013ADQLPG | Texas Instruments | 2.5V to 38V Hall Effect Latch 3-TO-92 -40 to 125 |
|
|
|
| DRV5023BIQDBZR | Texas Instruments | 2.5V to 38V Hall Effect Unipolar Switch 3-SOT-23 -40 to 125 |
|
|
|
| DRV5013ADQLPGM | Texas Instruments | 2.5V to 38V Hall Effect Latch 3-TO-92 -40 to 125 |
|
|
Documents mentioning LEM HALL EFFEC
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| lem current | LEM CURRENT TRANSDUCERS Module LTA 50-P/SP1 (Instantaneous Outputs) Definition - Principle The LEM type LTA 50-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided |
OCR Scan | ||||
| lem current | LEM CURRENT TRANSDUCERS Module LTA 100-P/SP1 (Instantaneous Outputs) Definition - Principle The LEM type LTA 100-P/SP1 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided |
OCR Scan | ||||
| LEM CURRENT TRANSDUCERS Module LTA 50-PR | LEM CURRENT TRANSDUCERS Module LTA 50-PR (Instantaneous and True RMS Outputs) Definition - Principle The LEM type LTA 50-PR is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided |
OCR Scan | ||||
| LEM CURRENT TRANSDUCERS Module LTA 100-PR | LEM CURRENT TRANSDUCERS Module LTA 100-PR (Instantaneous and True RMS Outputs) Definition - Principle The LEM type LTA 100-PR is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation is provided |
OCR Scan | ||||
| lem current | ■70 ^^ o S S/ /' oI ' LEM CURRENT TRANSDUCERS MODULE LTA 200-S/SP2 (Instantaneous Output) Deflnition - Principle The LEM type LTA 200-S/SP2 is a transducer employing the Hall effect to measure DC and complex waveform AC currents in a non invasive manner. Galvanic isolation |
OCR Scan | ||||
| lem current | LEM CURRENT TRANSDUCERS Module LTA 50P/SP1 ! cj ~7~ S (Instantaneous Outputs). 03, Definition - Principle The LEM type LTA50P/SP1 is a transducer employing the Hall Effect to measure D.C. and complex waveform A.C. currents in a non invasive manner. Galvanic isolation is provided between the primary (measured) and the analogue |
OCR Scan | ||||
| LEM CURRENT TRANSDUCERS M o d u les HAL *** S | LEM CURRENT TRANSDUCERS M o d u les HAL *** S Definition - Principle T*^ LEM type HAL *** S are transducers em ploying the Hall effect to measure DC and com plex waveform AC current in a n i-invasive manner. Galvanic isolation is provided between the primary (measured) and the analogue output (control) signal. |
OCR Scan | ||||
| lem current | LEM HEME LEM CURRENT TRANSDUCERS Module LTA100PR (Instantaneous and True RMS Outputs). Definition - Principle T h e L EM type LTA100PR is a transducer em ploying the Hall Effect to m easure D.C. and com plex w aveform A.C. currents in a n o n invasive m anner. Galvanic isolation is provided betw een the prim ary (m easured ) an d the analogue |
OCR Scan | ||||
| ha400s | LEM CURRENT TRANSDUCERS M odu les H A 400-S B , H A 400-S U , H A 400-S I H A 500-S B , H A 500-S U , H A 500-S I (In sta n ta n e o u s O u tp u ts) Definition - Principle The LEM type HA400S and HA500S are transducers employing the Hall Effect to measure D.C. and complex |
OCR Scan | ||||
| lem current | LEM CURRENT TRANSDUCERS M o d u les H A 200-SR U , H A 200-SR I H A 300-SR U , H A 300-SR I (T ru e RM S O u tp u ts) Definition - Principie The LEM type HA200SR and HA300SR are transducers employing the Hall Effect to measure D.C. and complex waveform A.C. currents in a non invasive manner. Galvanic isolation is provided between the primary (measured) and |
OCR Scan | ||||
| lem current | LEM CURRENT TRANSDUCERS M o d u les H A 400-SR U , H A 400-SR I H A 500-SR U , H A 500-SR I (T ru e RM S O u tp u ts ) Definition - Principle The LEM type HA400SR and HA500SR are transducers employing the Hall Effect to measure D.C. and complex waveform A.C. currents in a non invasive manner. Galvanic isolation is provided between the primary (measured) and |
OCR Scan | ||||
| LEM HEME Current Probe Type PR 2000 The PR 2000 | LEM HEME Current Probe Type PR 2000 The PR 2000 current probe is based on Hall Effect technology, for use in measurement of both DC and AC currents. Nominal current In Overload capacity Overall accuracy (at +25°C) Resolution Output sensitivity Gain variation |
OCR Scan | ||||
| lem current | HEMEL I, InternationalÊÊÊ LEM CURRENT TRANSDUCERS Module LTA 100P/SP1 lo7- (Instantaneous Outputs). Definition - Principle T he L EM type LTAIOOP/SPI is a transducer em ploying the Hall Effect to m easure D C and com plex w aveform A C currents in a non invasive m a n n e r Galvanic isolation is provided betw een the primary (m easured) and the analogue |
OCR Scan | ||||
| hah3dr | N AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 300-S03 Introduction The HAH3DR family gives you the choice of having different current measuring ranges in the same housing (from ± 100 A up to ± 900 A). The open loop transducers uses a Hall effect integrated circuit. |
Original | ||||
|
|
||||||
| sp600 | Current transducer FHS 40-P/SP600 I PM = 0 - 100 A Minisens FHS 40-P/SP600 transducer The Minisens transducer is an ultra flat SMD open loop integrated circuit current transducer based on the Hall effect principle. It is suitable for the electronic measurement of currents: DC, AC, pulsed, mixed. It has no insertion loss and |
Original | ||||
| fhs 40-p | Current transducer FHS 40-P/SP600 I PM = 0 - 100 A Minisens FHS 40-P/SP600 transducer The Minisens transducer is an ultra flat SMD open loop integrated circuit current transducer based on the Hall effect principle. It is suitable for the electronic measurement of currents: DC, AC, pulsed, mixed. It has no insertion loss and |
Original | ||||
| Current transducer FHS 40-P/SP600 I = 0 - 100 A | Current transducer FHS 40-P/SP600 I = 0 - 100 A PM Minisens Introduction The Minisens transducer is an ultra flat SMD open loop integrated circuit current transducer based on the Hall effect principle. It is suitable for the electronic measurement of currents: DC, AC, pulsed, mixed. It has no insertion loss and provides galvanic |
Original | ||||
| fhs 40-p/sp600 | Current transducer FHS 40-P/SP600 I = 0 - 100 A PM Minisens Introduction The Minisens transducer is an ultra lat SMD open loop integrated circuit current transducer based on the Hall effect principle. It is suitable for the electronic measurement of currents: DC, AC, pulsed, mixed. It has no insertion loss and provides galvanic |
Original | ||||
| hc2f100-sn | HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS Datasheet Page 1/ 6 071113/1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com HC2F100-SN CLIPS Introduction Principle of HC2F CLIPS Family |
Original | ||||