Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LCR CAPACITOR Search Results

    LCR CAPACITOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    FO-10GGBLCX20-001
    Amphenol Cables on Demand Amphenol FO-10GGBLCX20-001 LC-LC Duplex 10Gb Multimode 50/125 OM3 Fiber Optic Patch Cable - 2 x LC Male to 2 x LC Male 1m PDF
    FO-10GGBLCX20-005
    Amphenol Cables on Demand Amphenol FO-10GGBLCX20-005 LC-LC Duplex 10Gb Multimode 50/125 OM3 Fiber Optic Patch Cable - 2 x LC Male to 2 x LC Male 5m PDF
    FO-DUALLCX2MM-003
    Amphenol Cables on Demand Amphenol FO-DUALLCX2MM-003 LC-LC Duplex Multimode 62.5/125 Fiber Optic Patch Cable (OFNR Riser) - 2 x LC Male to 2 x LC Male 3m PDF
    FO-10GGBLCX20-010
    Amphenol Cables on Demand Amphenol FO-10GGBLCX20-010 LC-LC Duplex 10Gb Multimode 50/125 OM3 Fiber Optic Patch Cable - 2 x LC Male to 2 x LC Male 10m PDF
    FO-10GGBLCX20-015
    Amphenol Cables on Demand Amphenol FO-10GGBLCX20-015 LC-LC Duplex 10Gb Multimode 50/125 OM3 Fiber Optic Patch Cable - 2 x LC Male to 2 x LC Male 15m PDF

    Documents mentioning LCR CAPACITOR

    Document Partial File Text Tags Type PDF
    Models 885 & 886 LCR METER OPERATING MANUAL
    Models 885 & 886 LCR METER OPERATING MANUAL MANUAL DE INSTRUCCIÓNES MEDIDOR LCR Modelos 885 & 886 Contents 1. INTRODUCTION…1 1.1 GENERAL… 1
    Original PDF
    es51930
    ES51930 10kHz LCR analog front Features Description • 6000 counts ADC resolution The ES51930 is the analog frond end chip suitable for LCR bridge meter with simple DMM function. By using ES51930 to implement the LCR bridge meter, the complicated PCB design is not necessary. The
    Original PDF
    lcr capacitors
    LCR POLYPROPYLENE MOTOR RUN CAPACITOR LCR CAPACITORS TYPE: MR / P / 440 V . A C B THESE METALLISED POLYPROPYLENE CAPACITORS ARE PARTICULARLY SUITABLE FOR AC VOLTAGES. THESE CAPACITORS ARE CONSTRUCTED USING METALLISED POLYPROPYLENE FILM, HOUSED IN A PLASTIC CASE FILLED WITH POLYURETHANE
    Original PDF
    motor run capacitor
    LCR POLYPROPYLENE MOTOR RUN CAPACITOR LCR CAPACITORS TYPE : M R / A / 4 4 0 V THESE METALLISED POLYPROPYLENE CAPACITORS ARE PARTICULARLY SUITABLE FOR AC VOLTAGES ñ__ 0 THESE CAPACITORS ARE CONSTRUCTED USING METALLISED POLYPROPYLENE FILM. HOUSED IN AN ALUMINIUM CAN FILLED WITH POLYURETHANE
    OCR Scan PDF
    Agilent 4287A RF LCR Meter 1 MHz - 3 GHz
    Agilent 4287A RF LCR Meter 1 MHz - 3 GHz Technical Overview High-Speed RF LCR Meter Anticipating Next Generation Test Needs The Agilent 4287A is a high performance RF LCR meter best fit to production line testing of devices such as SMD inductors and EMI filters, where impedance testing at high frequencies is required.
    Original PDF
    lcr capacitors
    LCR POLYPROPYLENE MOTOR RUN CAPACITOR LCR CAPACITORS TYPE: MR / P / 250 V u A C B THESE METALLISED POLYPROPYLENE CAPACITORS ARE PARTICULARLY SUITABLE FOR AC VOLTAGES. THESE CAPACITORS ARE CONSTRUCTED USING METALLISED POLYPROPYLENE FILM, HOUSED IN A PLASTIC CASE FILLED WITH POLYURETHANE
    Original PDF
    esr meter
    49-2012:QuarkCatalogTempNew 9/20/12 1:18 PM Page 49 1 Component Test Equipment TEST & MEASUREMENT Digital LCR Meters Model 878B and 879B Hand-Held LCR Meters Models 885 (10 kHz) and 886 (100 kHz) Synthesized In-Circuit LCR/ESR Meter B&K Precision’s 878B and 879B 40,000 count L/C/R hand-held meters are designed
    Original PDF
    agilent 4263b
    Agilent 4263B LCR Meter 100 Hz to 100 kHz Technical Overview Introduction The Agilent Technologies LCR meter makes fast measurements on components. It is optimized for applications that require precision and versatility. The instrument's performance ranges
    Original PDF
    lcr capacitors
    LCR CAPACITORS LCR POLYPROPYLENE MOTOR RUN CAPACITOR i-i (î ) TYPE : MR / A / 440 V THESE METALLISED POLYPROPYLENE CAPACITORS ARE PARTICULARLY SUITABLE FOR AC VOLTAGES. THESE CAPACITORS ARE CONSTRUCTED USING METALLISED POLYPROPYLENE FILM, HOUSED IN AN ALUMINIUM CAN FILLED WITH POLYURETHANE
    OCR Scan PDF
    Guillaume Girard LCR Electronics Inc. 1 Solving
    Guillaume Girard LCR Electronics Inc. 1 Solving Electromagnetic Coupling Problems by Spatial Component Placement. Guillaume Girard EMC Engineer LCR Electronics Inc. 9 Forest Avenue Norristown, PA, 19401 United States Telephone: (610) 278-0840 Fax: (610) 278-0935
    Original PDF
    lcr components
    LCR. NYLON LCR COMPONENTS MOUNTING CLIP. For TUBULAR CAPACITORS. revised 20/2/96 issue 4 ceST N », 09104 'SC series 'S C SERIES For surface or central mounting. Metal clips can cut through the insulating sleave and cause problems which cannot occur with an insulating NYLON clip.
    OCR Scan PDF
    4285a
    Agilent 4284A/4285A Precision LCR Meter Family 20 Hz to 1 MHz 75 kHz to 30 MHz Technical Overview A new standard for precise component, semiconductor and material measurements Agilent precision LCR meter family Utilize state-of-the art measurement technologies
    Original PDF
    Integrating EMI Filters and Appliance Motor
    Integrating EMI Filters and Appliance Motor Controls Mr. Carl J. Dister LCR Electronics, Inc. 9 South Forest Avenue Norristown, PA 19401 U.S.A. Telephone: 1-800-527-4362 Fax: (610) 278-0935 Email: cdister@lcr-inc.com WEB Site: www.lcr-inc.com Carl J. Dister
    Original PDF
    lcr components
    (c> LCR. 3 " b Q j ‘o c)if S LCR COMPONENTS o For TUBULAR CAPACITORS. revised 20/2/96 issue 4 CERT. No Q5164 'S' series 'S' Series are particularly recommended where the capacitor cases should be isolated from the chassis on which they are fixed. The capacitor is raised 2mm off
    OCR Scan PDF
    llp3313-17l
    VEMI85LA-HGK Vishay Semiconductors 8-Channel LCR - EMI-Filter with ESD-Protection FEATURES • Ultra compact LLP3313-17L package • Low package profile of 0.6 mm • 8-channel LCR EMI-filter • Low leakage current • Line inductance LS = 10 nH • Line resistance RS = 12 Ω
    Original PDF
    LCR… your global source for EMI filters,
    LCR… your global source for EMI filters, electronic controls and assemblies. ^ 'L C S t E L m c m o m c s , incC ENGINEERED PRODUCT SOLUTIONS IN A CUSTOMER FOCUSED CULTURE MISSION STATEMENT LCR is dedicated to providing economically viable control and EMC
    OCR Scan PDF
    es51919/es51920
    ES51919/ES51920 LCR meter chipset Features Application • 19,999/1,999 counts dual LCD display Handheld LCR bridge meter • Current consumption: Typ. 14 mA @ 100kHz • QFP-100L package for ES51919 • SSOP-48L package for ES51920 Description The chipset of ES51919/ES51920 is suitable
    Original PDF