LC1-D32 CONTACTOR Search Results
LC1-D32 CONTACTOR Result Highlights (1)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| DRV3946QPWPRQ1 | Texas Instruments | Automotive 12-V contactor driver with current sensing and regulation 28-HTSSOP -40 to 125 |
|
Documents mentioning LC1-D32 CONTACTOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| tesys d contactors | TeSys contactors References TeSys D contactors for motor control up to 75 kW at 400 V, in category AC-3 810356 For connection by screw clamp terminals and lugs 3-pole contactors Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 (θ y 60 °C) |
Original | ||||
Selection 5 TeSys contactors 5 For utilisation category AC-3 Operational current and power conforming to IEC (θ y 60 °C) 1 Contactor size Maximum operational current in AC-3 Rated operational power P (standard motor power ratings) 2 3 y 440 V A LC1/ LP1 |
Original | |||||
| l | Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 (θ ≤ 55 °C) 1 Rated operational |
Original | ||||
| TeSys contactors References 537729 Component | TeSys contactors References 537729 Component parts for assembling reversing contactors for motor control, low-speed/high-speed starters and star-delta starters For 3-pole reversing contactors for motor control Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer |
Original | ||||
| contactor | Accessories Electronic Timers and Interface Modules www.SquareD.com FOR CURRENT INFORMATION The following accessories mount to the line-side of the contactors and connect at terminals A1 and A2. Electronic Serial Timer Modules These solid state modules delay the energizing and de-energizing of the contactor coil. |
Original | ||||
| d323 | References 4 Protection components 4 Fuse carriers 500504_1 3-pole basic blocks Rating Cartridge fuse size Number of early break contacts (1) Single-phase protection device (2) Reference (3) – (4) Without LS1 D323 0.270 Weight kg Connection by spring terminals |
Original | ||||
| Sélection Contactors Contactors for the North | Sélection Contactors Contactors for the North American market conforming to standards UL and CSA, 20 to 120 A Standard power ratings Taille of motors 50/60 Hz Size Single-phase 3-phase 1Ø 3Ø 115 V 230 V 200 V 230 V 460 V 575 V 240 V 208 V 240 V 480 V 600 V |
Original | ||||
| References 6 TeSys protection components 6 3-pole | References 6 TeSys protection components 6 3-pole thermal overload relays, model d 810464 Differential thermal overload relays for use with fuses b Compensated relays with manual or automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A) |
Original | ||||
| Issued November 2009 DATA SHEET LR-D OVERLOAD | Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common, |
Original | ||||
| tesys d contactors | TeSys contactors Characteristics TeSys D contactors Contactor type LC1 D09…D18 DT20 and DT25 D25…D38 DT32 and DT40 D40A…D65A DT60A and DT80A D80…D95 D115 and D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Conforming to IEC 60947-4-1, |
Original | ||||
| la6 dk10 | -127V 110 -DC z AC 60H 50/ E1 E2 LA6 DK10 LA1-DN10, DN01 LA6-DK 2 LA8-DN 2.3 LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor type and rating 2/78 Te Contactors and protection relays |
Original | ||||
| TeSys protection components Presentation, | TeSys protection components Presentation, description 3-pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively long starting times, |
Original | ||||
| Motor control 1 TeSys range provide you more | Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility… so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify |
Original | ||||
| 24516 Page 108 Friday, October 26, 2001 9:32 AM | 24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure, |
Original | ||||
|
|
||||||
| TeSys contactors References 526172 TeSys D, | TeSys contactors References 526172 TeSys D, 3-pole reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled 3-pole reversing contactors for connection by screw clamp terminals Pre-wired power connections. |
Original | ||||
| References TeSys contactors For motor control up | References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 810356 3-pole contactors for connection by screw clamp terminals or connectors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 |
Original | ||||
| tesys | 24531 Page 94 Thursday, October 25, 2001 6:02 PM Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 |
Original | ||||
| lc1-d09 | Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 b b b1 b1 LA4 D093… D183 99 107 123 (1) 132 (1) |
Original | ||||
| altivar 31 | Presentation Variable speed drives for asynchronous motors 2 Altivar 31 ESC ENT stop reset FWO REV 3 2 RUN 4 1 5 6 7 2 Presentation (continued) Variable speed drives for asynchronous motors 2 Altivar 31 Applications The Altivar 31 drive is a frequency inverter for 3-phase squirrel cage asynchronous |
Original | ||||
| lc1lc1lc1d09 | Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1, |
Original | ||||
| variable speed drives | Variable speed drives for asynchronous motors Altivar 11 Catalogue July at a reduced size!… VVDED202051EN 2002 Real efficiency Schneider Electric Industries SAS Headquarters 89, bd Franklin Roosevelt F - 92506 Rueil-Malmaison Cedex ART. 038998 http://www.schneider-electric.com |
Original | ||||
| tesys | 24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) |
Original | ||||
| lc | Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1, |
Original | ||||
| Soft starters ATS 01 Catalogue May 07 General | Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation… pages 1/2 and 1/3 |
Original | ||||
| Contactors and protection relays Selection guide | Contactors and protection relays Selection guide pages 1 '12 tu 1/43 References . uages 2/70 to 2''101 Dimensions pages 2/88 to 2*91 2/102 and 2/103 Schemes pages 2/92. 2'93 and 2 /’ 03 Type Contactors, types LC1-D and LP1-D Control circuit: a.c. or d.c. |
OCR Scan | ||||