Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LC1-D09 OPERATING Search Results

    LC1-D09 OPERATING Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TA75W01FU
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, Bipolar (358) type Dual Op-Amp, 3V to 12V, SOT-505 Datasheet
    TC75S67TU
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 2.2V to 5.5V, Low Noise type:VNI=6nV/√Hz@1kHz, SOT-353F Datasheet
    TC75S102F
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 1.5V to 5.5V, I/O Rail to Rail, IDD=0.27μA, SOT-25 Datasheet
    TC75S103F
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 1.8V to 5.5V, I/O Rail to Rail, IDD=100μA, SOT-25 Datasheet
    TC75S51F
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 1.5V to 7.0V, IDD=60μA, SOT-25/SOT-353 Datasheet

    Documents mentioning LC1-D09 OPERATING

    Document Partial File Text Tags Type PDF
    tesys contactors
    References TeSys contactors a.c. coils for 3-pole contactors LC1-D Control circuit voltage Uc V Average resistance at 20 °C ± 10 % Ω Inductance of closed circuit H Reference (1) Weight kg For 3-pole " contactors LC1-D09…D38 and LC1-DT20…DT60 Specifications
    Original PDF
    tesys d contactors
    TeSys contactors Characteristics TeSys D contactors Contactor type LC1 D09…D18 DT20 and DT25 D25…D38 DT32 and DT40 D40A…D65A DT60A and DT80A D80…D95 D115 and D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Conforming to IEC 60947-4-1,
    Original PDF
    Issued November 2009 DATA SHEET LR-D OVERLOAD
    Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common,
    Original PDF
    tesys d contactors
    TeSys contactors References TeSys D contactors for motor control up to 75 kW at 400 V, in category AC-3 810356 For connection by screw clamp terminals and lugs 3-pole contactors Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 (θ y 60 °C)
    Original PDF
    l
    Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 (θ ≤ 55 °C) 1 Rated operational
    Original PDF
    Selection 5 TeSys contactors 5 For utilisation
    Selection 5 TeSys contactors 5 For utilisation category AC-3 Operational current and power conforming to IEC (θ y 60 °C) 1 Contactor size Maximum operational current in AC-3 Rated operational power P (standard motor power ratings) 2 3 y 440 V A LC1/ LP1
    Original PDF
    References 6 TeSys protection components 6 3-pole
    References 6 TeSys protection components 6 3-pole thermal overload relays, model d 810464 Differential thermal overload relays for use with fuses b Compensated relays with manual or automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A)
    Original PDF
    TeSys protection components Presentation,
    TeSys protection components Presentation, description 3-pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively long starting times,
    Original PDF
    Soft starters ATS 01 Catalogue May 07 General
    Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation… pages 1/2 and 1/3
    Original PDF
    variable speed drives
    Variable speed drives for asynchronous motors Altivar 11 Catalogue July at a reduced size!… VVDED202051EN 2002 Real efficiency Schneider Electric Industries SAS Headquarters 89, bd Franklin Roosevelt F - 92506 Rueil-Malmaison Cedex ART. 038998 http://www.schneider-electric.com
    Original PDF
    lr97
    TeSys protection components Presentation, description Electronic over current relays Presentation 109487 LR97 D and LT47 electronic over current relays have been developed to satisfy machine protection requirements. These relays have definite time characteristics: current threshold and time based function.
    Original PDF
    la6 dk10
    -127V 110 -DC z AC 60H 50/ E1 E2 LA6 DK10 LA1-DN10, DN01 LA6-DK 2 LA8-DN 2.3 LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor type and rating 2/78 Te Contactors and protection relays
    Original PDF
    24516 Page 108 Friday, October 26, 2001 9:32 AM
    24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure,
    Original PDF
    Motor control 1 TeSys range provide you more
    Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility… so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify
    Original PDF
    tesys
    References 6 TeSys protection components 3-pole thermal overload relays, model d 24515-EN_Ver7.0.fm/2 6 References (continued) 6 TeSys protection components 6 3-pole thermal overload relays, model d Accessories Accessories (to be ordered separately) 533574
    Original PDF
    l
    References TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using 2 identical contactors 810373 Contactors with screw clamp terminals or connectors
    Original PDF
    altivar 31
    Presentation Variable speed drives for asynchronous motors 2 Altivar 31 ESC ENT stop reset FWO REV 3 2 RUN 4 1 5 6 7 2 Presentation (continued) Variable speed drives for asynchronous motors 2 Altivar 31 Applications The Altivar 31 drive is a frequency inverter for 3-phase squirrel cage asynchronous
    Original PDF
    lc1
    Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1,
    Original PDF
    lc1lc1lc1d09
    Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1,
    Original PDF
    tesys
    24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui)
    Original PDF
    Variable speed drives Altivar 32 For 3-phase
    Variable speed drives Altivar 32 For 3-phase motors from 0.18 to 15 kW Catalogue April 2010 All technical information about products listed in this catalogue are now available on: www.schneider-electric.com Browse the “product data sheet” to check out:
    Original PDF
    altivar 31
    Variable speed drives Altivar 312 Catalogue April 2009 General contents Variable speed drives Altivar 312 b Brochure… page 2 b Catalogue… page 11
    Original PDF
    global specialist in energy management The
    global specialist in energy management The architects of efficiency Singapore Mongolia Price List Catalogue 2013 Electrical Distribution, Automation & Control  ! % 3% %3 (    3'33, )3 3% %3 (  +3&-==33&2/=
    Original PDF