LC1 T CONTACTOR Search Results
LC1 T CONTACTOR Result Highlights (1)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| DRV3946QPWPRQ1 | Texas Instruments | Automotive 12-V contactor driver with current sensing and regulation 28-HTSSOP -40 to 125 |
|
Documents mentioning LC1 T CONTACTOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| l | Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 (θ ≤ 55 °C) 1 Rated operational |
Original | ||||
| tesys | 24531 Page 94 Thursday, October 25, 2001 6:02 PM Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 |
Original | ||||
| lc1-d09 | Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 b b b1 b1 LA4 D093… D183 99 107 123 (1) 132 (1) |
Original | ||||
| in | Telemecanique D contactors and overload relays D115-59kw AC3 D150-80kw AC3 Telemecaniques’ D range is the world’s number one in contactors. Two new D range contactors are now available, expanding the range to 80kw AC3 for motor control and 200A AC1 for distribution |
OCR Scan | ||||
| Soft starters ATS 01 Catalogue May 07 General | Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation… pages 1/2 and 1/3 |
Original | ||||
| altivar 31 | Presentation Variable speed drives for asynchronous motors 2 Altivar 31 ESC ENT stop reset FWO REV 3 2 RUN 4 1 5 6 7 2 Presentation (continued) Variable speed drives for asynchronous motors 2 Altivar 31 Applications The Altivar 31 drive is a frequency inverter for 3-phase squirrel cage asynchronous |
Original | ||||
| 60947 | 22100_Ver2.00-EN.backup.fm Page 2 Thursday, October 25, 2001 4:40 PM Characteristics Contactors Mini-contactors types LC1-SK and LP1-SK Environment Rated insulation voltage (Ui) 2 2.1 Conforming to IEC/EN 60947-1, IEC/EN 60947-4-1, VDE 0110 gr C, CSA 22-2 n˚ 14, UL 508 |
Original | ||||
| variable speed drives | Variable speed drives for asynchronous motors Altivar 11 Catalogue July at a reduced size!… VVDED202051EN 2002 Real efficiency Schneider Electric Industries SAS Headquarters 89, bd Franklin Roosevelt F - 92506 Rueil-Malmaison Cedex ART. 038998 http://www.schneider-electric.com |
Original | ||||
| altivar 31 | Variable speed drives Altivar 312 Catalogue April 2009 General contents Variable speed drives Altivar 312 b Brochure… page 2 b Catalogue… page 11 |
Original | ||||
| Issued November 2009 DATA SHEET LR-D OVERLOAD | Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common, |
Original | ||||
| Characteristics Contactors Contactors and | Characteristics Contactors Contactors and reversing contactors types LCp-K and LPp-K Environment Conforming to standards Approvals LCp and LPp-K06 to K12 Operating positions Vertical axis Horizontal axis Without derating Without derating UL, CSA, DEMKO, NEMKO, SEMKO, FI |
Original | ||||
| 22005_Ver8.00-EN.backup.fm Page 18 Thursday, | 22005_Ver8.00-EN.backup.fm Page 18 Thursday, October 25, 2001 4:59 PM Characteristics Contactors Contactors and reversing contactors types LCp-K and LPp-K Environment Conforming to standards Approvals LCp and LPp-K06 to K12 Operating positions Vertical axis |
Original | ||||
| lr97 | TeSys protection components Presentation, description Electronic over current relays Presentation 109487 LR97 D and LT47 electronic over current relays have been developed to satisfy machine protection requirements. These relays have definite time characteristics: current threshold and time based function. |
Original | ||||
| Motor control 1 TeSys range provide you more | Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility… so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify |
Original | ||||
|
|
||||||
| t | Variable speed drives Altivar 32 For 3-phase motors from 0.18 to 15 kW Catalogue April 2010 All technical information about products listed in this catalogue are now available on: www.schneider-electric.com Browse the “product data sheet” to check out: |
Original | ||||
| l | TeSys protection components Presentation, description 3-pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively long starting times, |
Original | ||||
| lc1-d115 | Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1, |
Original | ||||
| tesys | 24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) |
Original | ||||
| lc1lc1lc1d09 | Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1, |
Original | ||||
| Characteristics Contactors Contactors and | Characteristics Contactors Contactors and reversing contactors types LCp-K and LPp-K Environment Conforming to standards Approvals p and LPp p-K06 to K12 LCp Operating positions Vertical axis Horizontal axis Without derating Without derating UL, CSA, DEMKO, NEMKO, SEMKO, FI |
Original | ||||
| 24516 Page 108 Friday, October 26, 2001 9:32 AM | 24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure, |
Original | ||||
| sc | References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 810356 3-pole contactors for connection by screw clamp terminals or connectors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 |
Original | ||||
| lc | Contactors and protection relays Selection guide pages 1 '12 tu 1/43 References . uages 2/70 to 2''101 Dimensions pages 2/88 to 2*91 2/102 and 2/103 Schemes pages 2/92. 2'93 and 2 /’ 03 Type Contactors, types LC1-D and LP1-D Control circuit: a.c. or d.c. |
OCR Scan | ||||
| 2008 SQUARE D REF GUIDE Flip 0514.qxd SQUARE D® | 2008 SQUARE D REF GUIDE Flip 0514.qxd SQUARE D® INFORMATION RESOURCES Local Square D Sales Office: (____)_______________ Square D Customer Information Center: 1-888-SQUARE D (1-888-778-2733) The 2008 Pocket Digest still contains Schneider Electric’s best selling catalog numbers from |
Original | ||||
| jigo products | ® JiGO PRODUCTS CATALOGUE it all began in 1987…. The founder hit upon the electrical business in 1987 in the financial hub of eastern India, Kolkata. In midst of severe competition and tough markets, their values and committment towards quality and customer service set them apart from |
Original | ||||