LC1 D12 Search Results
LC1 D12 Datasheets (3)
Select Manufacturer
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |
|---|---|---|---|---|---|---|---|
| LC1-D12 | Schneider Electric | TeSys contactors | Original | 115.88KB | 12 | ||
| LC1-D12 | Telemecanique | Contactors and protection relays | Original | 22.07KB | 1 | ||
| LC1-D12 | Telemecanique | Contactors and Protection Relays | Scan | 558.17KB | 6 |
LC1 D12 Price and Stock
Schneider Electric
Schneider Electric LC1D12BDContactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 24VDC; 12A |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D12BD | 144 | 1 |
|
Buy Now | ||||||
Schneider Electric LC1D128E7Contactor: 4-pole; NC x2 + NO x2; Auxiliary contacts: NC + NO |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D128E7 | 30 | 1 |
|
Buy Now | ||||||
|
LC1D128E7 | Bulk | 1 | 1 Weeks | 1 |
|
Buy Now | ||||
Schneider Electric LC1D12U7Contactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 240VAC; 12A |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D12U7 | 27 | 1 |
|
Buy Now | ||||||
|
LC1D12U7 | 2 | 1 |
|
Buy Now | ||||||
|
LC1D12U7 | 16 |
|
Buy Now | |||||||
|
LC1D12U7 | 3 |
|
Buy Now | |||||||
Schneider Electric LC1D123B7Contactor: 3-pole; NO x3; Auxiliary contacts: NC + NO; 24VAC; 12A |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D123B7 | 15 | 1 |
|
Buy Now | ||||||
Schneider Electric LC1D12E5Contactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 48VAC; 12A |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D12E5 | 9 | 1 |
|
Buy Now | ||||||
Documents mentioning LC1 D12
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| LA 9-D 09 978 Kit condamnation MECHANICAL | LA 9-D 09 978 Kit condamnation MECHANICAL INTERLOCK KIT VERRIEGELUNG MECHANISCH FÜR WENDESCHÜTZE KIT D’INTERBLOCCO KIT CONDENACION KIT DE ENCRAVAMENTO MECÁNICO W9 0378144 01 32 p«Te»em ecanique D09 % D12 D18 ---- O , ---- ---- D25 D32 — LC1 LP1 LC1 LP1 LC1 LP1 LC1 LP1 LC1 LP1 |
OCR Scan | ||||
| tesys | 24531 Page 94 Thursday, October 25, 2001 6:02 PM Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 |
Original | ||||
| lc1-d09 | Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 b b b1 b1 LA4 D093… D183 99 107 123 (1) 132 (1) |
Original | ||||
| lc1-d115 | Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1, |
Original | ||||
| lc1lc1lc1d09 | Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1, |
Original | ||||
| tesys | 24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) |
Original | ||||
| tesys d contactors | TeSys contactors Characteristics TeSys D contactors Contactor type LC1 D09…D18 DT20 and DT25 D25…D38 DT32 and DT40 D40A…D65A DT60A and DT80A D80…D95 D115 and D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Conforming to IEC 60947-4-1, |
Original | ||||
| Selection 5 TeSys contactors 5 For utilisation | Selection 5 TeSys contactors 5 For utilisation category AC-3 Operational current and power conforming to IEC (θ y 60 °C) 1 Contactor size Maximum operational current in AC-3 Rated operational power P (standard motor power ratings) 2 3 y 440 V A LC1/ LP1 |
Original | ||||
| lc1-d | Contactors and protection relays Contactors, types LC1-D Selection guide : pages 1/12 to 1/43 Characteristics : pages 2/56 to 2/69 References : pages 2/70 to 2/77 Schemes : pages 2/92 and 2/93 Dimensions c 12,5 (LA8) c1(LA1) 45 12,5 (LA8) 56 107(3)(DF,DT) |
Original | ||||
Contactors and protection relays Selection guide pages 1 '12 tu 1/43 References . uages 2/70 to 2''101 Dimensions pages 2/88 to 2*91 2/102 and 2/103 Schemes pages 2/92. 2'93 and 2 /’ 03 Type Contactors, types LC1-D and LP1-D Control circuit: a.c. or d.c. |
OCR Scan | |||||
| la6 dk10 | -127V 110 -DC z AC 60H 50/ E1 E2 LA6 DK10 LA1-DN10, DN01 LA6-DK 2 LA8-DN 2.3 LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor type and rating 2/78 Te Contactors and protection relays |
Original | ||||
| lc1 d09 | 5 0 /6 0 HZ AC3 DUTY SINGLE PHASE CATALOG 1 15V 230V D09 0.5 HP 1 HP D12 1 HP 2 HP D18 1 HP 3 HP 200V 2 HP 3 HP 5 HP THREE 230V 2 HP 3 HP 5 HP PHASE 460V 5 HP 7.5 HP 10 HP 575V 7.5 HP 10 HP 15 HP COIL VOLTAGES FOR LC1 D09 TO D80 VOLTS 12 24 48 72 110 125 115 |
OCR Scan | ||||
| tesys d contactors | TeSys contactors References TeSys D contactors for motor control up to 75 kW at 400 V, in category AC-3 810356 For connection by screw clamp terminals and lugs 3-pole contactors Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 (θ y 60 °C) |
Original | ||||
| TeSys contactors References 537729 Component | TeSys contactors References 537729 Component parts for assembling reversing contactors for motor control, low-speed/high-speed starters and star-delta starters For 3-pole reversing contactors for motor control Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer |
Original | ||||
|
|
||||||
| Soft starters ATS 01 Catalogue May 07 General | Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation… pages 1/2 and 1/3 |
Original | ||||
| Issued November 2009 DATA SHEET LR-D OVERLOAD | Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common, |
Original | ||||
| variable speed drives | Variable speed drives for asynchronous motors Altivar 11 Catalogue July at a reduced size!… VVDED202051EN 2002 Real efficiency Schneider Electric Industries SAS Headquarters 89, bd Franklin Roosevelt F - 92506 Rueil-Malmaison Cedex ART. 038998 http://www.schneider-electric.com |
Original | ||||
| Contactors d 3-pole contactors for motor control, | Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 (θ ≤ 55 °C) 1 Rated operational |
Original | ||||
| Motor control 1 TeSys range provide you more | Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility… so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify |
Original | ||||
| TeSys protection components Presentation, | TeSys protection components Presentation, description 3-pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively long starting times, |
Original | ||||
| References 6 TeSys protection components 6 3-pole | References 6 TeSys protection components 6 3-pole thermal overload relays, model d 810464 Differential thermal overload relays for use with fuses b Compensated relays with manual or automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A) |
Original | ||||
| TeSys contactors References 526172 TeSys D, | TeSys contactors References 526172 TeSys D, 3-pole reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled 3-pole reversing contactors for connection by screw clamp terminals Pre-wired power connections. |
Original | ||||
| Libraries Guide Xilinx Unified Libraries | Libraries Guide Xilinx Unified Libraries Selection Guide Design Elements (ACC1 to BYPOSC) Design Elements (CAPTURE_VIRTEX to DECODE64) Design Elements (F5MAP to FTSRLE) Design Elements (GCLK to KEEPER) Design Elements (LD to NOR16) Design Elements (OAND2 to OXOR2) |
Original | ||||
| spartan2 | Libraries Guide Xilinx Unified Libraries Selection Guide Design Elements (ACC1 to BYPOSC) Design Elements (CAPTURE_SPARTAN2 to DECODE64) Design Elements (F5MAP to FTSRLE) Design Elements (GCLK to KEEPER) Design Elements (LD to NOR16) Design Elements (OAND2 to OXOR2) |
Original | ||||
| 24516 Page 108 Friday, October 26, 2001 9:32 AM | 24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure, |
Original | ||||