LC1 CONTACTOR 3 PHASE Search Results
LC1 CONTACTOR 3 PHASE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TB6551FAG | Toshiba Electronic Devices & Storage Corporation | Brushless Motor Driver/3 Phases Controller/Vout(V)=12/Sine Wave | Datasheet | ||
| TB6586FG | Toshiba Electronic Devices & Storage Corporation | Brushless Motor Driver/3 Phases Controller/Vout(V)=18/Square Wave | Datasheet | ||
| TB62213AFNG | Toshiba Electronic Devices & Storage Corporation | Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=3/Phase Interface | Datasheet | ||
| TB62261FTG | Toshiba Electronic Devices & Storage Corporation | Stepping Motor Driver/Bipolar Type/Vout(V)=40/Iout(A)=1.8/Phase Interface | Datasheet | ||
| TB67S141NG | Toshiba Electronic Devices & Storage Corporation | Stepping Motor Driver/Unipolar Type/Vout(V)=84/Iout(A)=3/Phase Interface | Datasheet |
Documents mentioning LC1 CONTACTOR 3 PHASE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| contactor | References 5 Contactors 5 Mini-contactors types LC1 SK and LP1 SK b Width of contactor 27 mm. b Mounting on 35 mm 7 rail. b Screw clamp terminals. 812717 Mini-contactors for motor in category AC-3 Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 (1) |
Original | ||||
| Sélection Contactors Contactors for the North | Sélection Contactors Contactors for the North American market conforming to standards UL and CSA, 20 to 120 A Standard power ratings Taille of motors 50/60 Hz Size Single-phase 3-phase 1Ø 3Ø 115 V 230 V 200 V 230 V 460 V 575 V 240 V 208 V 240 V 480 V 600 V |
Original | ||||
TeSys contactors References TeSys D contactors for motor control up to 75 kW at 400 V, in category AC-3 810356 For connection by screw clamp terminals and lugs 3-pole contactors Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 (θ y 60 °C) |
Original | |||||
| lc1 d09 | 5 0 /6 0 HZ AC3 DUTY SINGLE PHASE CATALOG 1 15V 230V D09 0.5 HP 1 HP D12 1 HP 2 HP D18 1 HP 3 HP 200V 2 HP 3 HP 5 HP THREE 230V 2 HP 3 HP 5 HP PHASE 460V 5 HP 7.5 HP 10 HP 575V 7.5 HP 10 HP 15 HP COIL VOLTAGES FOR LC1 D09 TO D80 VOLTS 12 24 48 72 110 125 115 |
OCR Scan | ||||
| d323 | References 4 Protection components 4 Fuse carriers 500504_1 3-pole basic blocks Rating Cartridge fuse size Number of early break contacts (1) Single-phase protection device (2) Reference (3) – (4) Without LS1 D323 0.270 Weight kg Connection by spring terminals |
Original | ||||
| l | Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 (θ ≤ 55 °C) 1 Rated operational |
Original | ||||
| TeSys protection components Presentation, | TeSys protection components Presentation, description 3-pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively long starting times, |
Original | ||||
| altivar 31 | Presentation Variable speed drives for asynchronous motors 2 Altivar 31 ESC ENT stop reset FWO REV 3 2 RUN 4 1 5 6 7 2 Presentation (continued) Variable speed drives for asynchronous motors 2 Altivar 31 Applications The Altivar 31 drive is a frequency inverter for 3-phase squirrel cage asynchronous |
Original | ||||
| Motor control 1 TeSys range provide you more | Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility… so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify |
Original | ||||
| Soft starters ATS 01 Catalogue May 07 General | Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation… pages 1/2 and 1/3 |
Original | ||||
| Mini contactors K 3-pole contactors for motor | Mini contactors K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c References a.c. control contactors (1) - Mounting on 35 mm " rail or Ø 4 mm screw fixing. - Screws in open “ready-to-tighten” position. |
Original | ||||
| Issued November 2009 DATA SHEET LR-D OVERLOAD | Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common, |
Original | ||||
| Telemecanique D contactors and overload relays | Telemecanique D contactors and overload relays D115-59kw AC3 D150-80kw AC3 Telemecaniques’ D range is the world’s number one in contactors. Two new D range contactors are now available, expanding the range to 80kw AC3 for motor control and 200A AC1 for distribution |
OCR Scan | ||||
| Variable speed drives Altivar 32 For 3-phase | Variable speed drives Altivar 32 For 3-phase motors from 0.18 to 15 kW Catalogue April 2010 All technical information about products listed in this catalogue are now available on: www.schneider-electric.com Browse the “product data sheet” to check out: |
Original | ||||
|
|
||||||
| 24516 Page 108 Friday, October 26, 2001 9:32 AM | 24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure, |
Original | ||||
| lr97 | TeSys protection components Presentation, description Electronic over current relays Presentation 109487 LR97 D and LT47 electronic over current relays have been developed to satisfy machine protection requirements. These relays have definite time characteristics: current threshold and time based function. |
Original | ||||
| Selection guide TeSys Model U Starter-controllers | Selection guide TeSys Model U Starter-controllers Control units Function characteristics Control units Standard LUCA Thermal overload protection Overcurrent protection Advanced LUCB LUCC LUCD 14.2 x the setting current Short-circuit protection Protection against phase loss |
Original | ||||
| Characteristics Contactors Contactors and | Characteristics Contactors Contactors and reversing contactors types LCp-K and LPp-K Environment Conforming to standards Approvals p and LPp p-K06 to K12 LCp Operating positions Vertical axis Horizontal axis Without derating Without derating UL, CSA, DEMKO, NEMKO, SEMKO, FI |
Original | ||||
| References TeSys contactors For motor control up | References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 810356 3-pole contactors for connection by screw clamp terminals or connectors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 |
Original | ||||
Contactors F 3-pole contactors for motor control, 115 to 780 A Utilisation category AC-3 Control circuit : a.c. or d.c. c or a References 3-pole contactors 1 Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC-3 |
Original | |||||
| altivar 31 | Variable speed drives Altivar 312 Catalogue April 2009 General contents Variable speed drives Altivar 312 b Brochure… page 2 b Catalogue… page 11 |
Original | ||||
Issued November 1991 B12570 Direct on line(DOL)starters TelemecaniqueÔd2Õ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique Ôd2Õ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and VDE 0660. RS stock no. |
Original | |||||
| telemecanique | Issued November 1991 012-570 Data Pack B Data Sheet Direct on line (DOL) starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique ‘d2’ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and |
Original | ||||
| telemecanique | Issued March 1997 232-3591 Data Pack B Data Sheet Direct on line (DOL) starters Telemecanique ‘d2’ range A range of 4 and 9kW direct on line ac starters using the new Telemecanique ‘d2’ motor control gear range and conforming to IEC 947-4, IEC 292-1, BS4941 and |
Original | ||||
| variable speed drives | Variable speed drives for asynchronous motors Altivar 11 Catalogue July at a reduced size!… VVDED202051EN 2002 Real efficiency Schneider Electric Industries SAS Headquarters 89, bd Franklin Roosevelt F - 92506 Rueil-Malmaison Cedex ART. 038998 http://www.schneider-electric.com |
Original | ||||