LANDIS AND STAEFA CONTROLLER Search Results
LANDIS AND STAEFA CONTROLLER Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| AV-THLIN2BNCM-005 | Amphenol Cables on Demand | Amphenol AV-THLIN2BNCM-005 Thin-line Coaxial Cable - BNC Male / BNC Male (SDI Compatible) 5ft | |||
| CN-DSUB25PIN0-000 | Amphenol Cables on Demand | Amphenol CN-DSUB25PIN0-000 D-Subminiature (DB25 Male D-Sub) Connector, 25-Position Pin Contacts, Solder-Cup Terminals | |||
| CN-DSUBHD26PN-000 | Amphenol Cables on Demand | Amphenol CN-DSUBHD26PN-000 High-Density D-Subminiature (HD26 Male D-Sub) Connector, 26-Position Pin Contacts, Solder-Cup Terminals | |||
| CO-058BNCRBNC-010 | Amphenol Cables on Demand | Amphenol CO-058BNCRBNC-010 BNC Male to BNC Right Angle Male (RG58) 50 Ohm Coaxial Cable Assembly 10ft | |||
| CO-058BNCX200-012 | Amphenol Cables on Demand | Amphenol CO-058BNCX200-012 BNC Male to BNC Male (RG58) 50 Ohm Coaxial Cable Assembly 12ft |
Documents mentioning LANDIS AND STAEFA CONTROLLER
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| qpa84 | 1 Indoor Air Quality Controller 571 QPA84 With integrated VOC 1) ) sensor, operating voltage AC 230 V, two-position output (non-potential-free relay contact) 1) VOC = Volatile Organic Compounds Use In ventilation plant to optimize the indoor air quality and the consumption of energy by |
Original | ||||
| qaa32 | 1 747 Room Temperature Sensor QAA32 NTC resistor sensing element Use In HVAC plants to acquire the room temperature. Functions 1747D01 Ω 9000 7000 5000 The sensor acquires the room temperature by means of its NTC resistor. The resistance value changes according to the ambient |
Original | ||||
| air velocity sensor | 1 1932P01 932 Air velocity sensor QVM62.1 Use This sensor is used to control the air velocity to a constant value, or to balance out pressure fluctuations (supply or extract air control), or to monitor the flow in air ducts. It primarily is used for modulating fan control in primary plants to set the basic volume |
Original | ||||
| transducer | 5 Signal transducer (T1) for Ni1000 temperature sensor 142 AQA61.20 Signal transducer allowing the use of Ni1000 sensors for controllers with a T1 sensor input. Converts an Ni1000 sensor signal into a T1-type output signal Transducer supply from connected controller |
Original | ||||
| 1860p01 | 1 1860P01 860 QFM65.1 Duct sensor for relative humidity and temperature Operating voltage AC 24 V Signal output DC 0…10 V for relative humidity Signal output L&S Ni 1000 (passive) for temperature Measurement accuracy ± 3 % r. h. within the comfort range |
Original | ||||
| duct temperature sensor | 1 Duct temperature sensor 778 FK-TP/200 for HVAC systems Duct temperature sensor for heating, ventilation and air conditioning systems – For use with controllers with Pt100 sensor inputs – In conjunction with MULTIREG and INTEGRAL RS. Use The FK-TP/200 duct temperature sensor can be used in air ducts for heating, ventilation |
Original | ||||
| qad26 | 1 Clamp-on Temperature Sensor 802 QAD26.220 Use Heating, ventilation, air conditioning and refrigeration plant. Acquisition of the medium temperature in pipes from −35 to +90 °C to provide measurement, limitation, compensation, or control. Ordering and |
Original | ||||
| B C Actuators for heating, ventilation, | B C Actuators for heating, ventilation, air-conditioning -CD Product Information Damper actuators NM i0027811 2. NM-3 B C LM NM SM AM GM LF AF 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 For dampers Spring return |
Original | ||||
| B C Actuators for heating, ventilation, | B C Actuators for heating, ventilation, air-conditioning Product Information Damper actuators GM i0029901 2. GM-3 B C LM NM SM AM GM LF AF 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 For dampers Spring return |
Original | ||||
| B C Actuators for heating, ventilation, | B C Actuators for heating, ventilation, air-conditioning Product Information Damper actuators SM i0028811 2. SM-3 B C LM NM SM AM GM LF AF 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 For dampers Spring return |
Original | ||||
| B C Actuators for heating, ventilation, | B C Actuators for heating, ventilation, air-conditioning Product Information Damper actuators SM i0028811 2. SM-4 B C LM NM SM AM GM LF AF(R) 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 For dampers Spring return |
Original | ||||
| Process and Industrial Controls Application Note | Process and Industrial Controls Application Note With the continuing automation of industrial processes, remote monitoring and control is becoming increasingly important in industrialcontrol arenas. Modern installations need control systems that guarantee accurate communications between different decision |
Original | ||||
| B C Actuators for heating, ventilation, | B C Actuators for heating, ventilation, air-conditioning -CD Product Information Damper actuators LM i0026809 2. LM-4 B C NM SM AM GM LF AF 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 i0084803 LM For dampers Spring return |
Original | ||||
| 10129 LIST OF COMPANY IDENTIFICATIONS The List of | 10129 LIST OF COMPANY IDENTIFICATIONS The List of Company Identifications contains the trade names, trademarks, or other designations authorized for use in lieu of these Company names. ‘‘ ’’ — 2CS SRL ’’ — ACT CO LTD ‘‘‘ ’’ — 3E (HK) LTD |
Original | ||||
|
|
||||||
NEED IT NOW? BUY REMAN! SEE PAGE lxx xx xvi SOLUTIONS, SOLUTIONS… Q A r e q u a l i t y, c o s t , a n d t i m e i m p o r t a n t to you? A ELECTRICAL SOUTH! Q Do you spend too much of your valuable time dealing with too m a n y d i ff e r e n t r e p a i r v e n d o r s ? |
Original | |||||