LAMBDA VEGA 6 Search Results
LAMBDA VEGA 6 Result Highlights (2)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| LM9044V/NOPB | Texas Instruments | Lambda Sensor Interface Amplifier 20-PLCC -40 to 125 |
|
|
|
| LM9044VX/NOPB | Texas Instruments | Lambda Sensor Interface Amplifier 20-PLCC -40 to 125 |
|
|
Documents mentioning LAMBDA VEGA 6
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| lambda vega | LAMBDA Vega Spec. P5 Vega Series Multiple Output Power Supply Specification Rev. P5 DOC # Vega Spec.doc Page 1 of 19 LAMBDA Vega Spec. P5 General The Vega modular power supply addresses the need for 450W and 650W multiple output requirements. The series is comprised |
Original | ||||
| vega | Vega 650 DVT Results Vega 650 5000M Altitude 5000M Altitude For NRAO Product Code – K60154 Serial Number - 2070710164 Date – 3/5/07 Date Issued: 15/4/07 Tested By: A.Irwin Lambda UK Confidential Checked By: Vega 650 DVT Results Vega 650 5000M Altitude |
Original | ||||
| vega | Vega Applications Manual Section 4 - Output Ripple and Noise The Measurement of ripple and noise. Lambda measures ripple and noise on switching power supplies using an oscilloscope with the bandwidth limited to 20Mhz. The measurement is taken at the end of a 150mm length pair of twisted cables terminated |
Original | ||||
| Power + INNOVATION • SOLUTIONS • SUPPORT • | Power + INNOVATION • SOLUTIONS • SUPPORT • RELIABILITY • Industry Leading Power Density • Up to 11 outputs • Voltages up to 62V, Current up to 114 Amps • Screw, Fast-on or IEC connection • Worldwide approvals & CB report • Medical Approval Option |
Original | ||||
| Power + INNOVATION • SOLUTIONS • SUPPORT • | Power + INNOVATION • SOLUTIONS • SUPPORT • RELIABILITY • Industry Leading Power Density • Up to 11 outputs • Voltages up to 62V, Current up to 114 Amps • Screw, Fast-on or IEC connection • Worldwide approvals & CB report • Medical Approval Option |
Original | ||||
| Power + INNOVATION • SOLUTIONS • SUPPORT • | Power + INNOVATION • SOLUTIONS • SUPPORT • RELIABILITY • Industry Leading Power Density • Up to 11 outputs • Voltages up to 62V, Current up to 114 Amps • Screw, Fast-on or IEC connection • Worldwide approvals & CB report • Medical Approval Option |
Original | ||||
| Power + INNOVATION • SOLUTIONS • SUPPORT • | Power + INNOVATION • SOLUTIONS • SUPPORT • RELIABILITY • Industry Leading Power Density • 1 to 11 outputs • Voltages from 1.8 to 56V • Current up to 60 Amps • Screw connection • Worldwide approvals & CB report • Medical Approval Option |
Original | ||||
| Vega 450 & 650 Watts ! Industry leading Power | Vega 450 & 650 Watts ! Industry leading Power Density ! 1 to 10 outputs ! Voltages from 1.8 – 62V ! Current up to 120 Amps ! Screw, Fast-on or IEC connection ! Worldwide approvals & CB report ! Low leakage current for Medical The world’s most configurable power supply |
Original | ||||
| Vega 450, 650 & 900 Watts ¾ Industry leading | Vega 450, 650 & 900 Watts ¾ Industry leading Power Density ¾ 1 to 10 outputs ¾ Voltages from 0.25 – 62V ¾ Current up to 114 Amps ¾ Screw, Fast-on or IEC connection ¾ Worldwide approvals & CB report ¾ Low leakage current for Medical The world’s most configurable power supply |
Original | ||||
| lambda | TOLL FREE-1.800.LAMBDA4 http://www.lambdapower.com CORPORATE HEADQUARTERS 3055 Del Sol Blvd. San Diego, California 92154 TECHNICAL SUPPORT DIVISION 3055 Del Sol Blvd. San Diego, California 92154 Telephone. 619.575.4400 Facsimile. 619.429.1011 Telephone. 1-800-LAMBDA4 |
Original | ||||
| Power + INNOVATION • SOLUTIONS • SUPPORT • | Power + INNOVATION • SOLUTIONS • SUPPORT • RELIABILITY • Industry Leading Power Density • 1 to 11 outputs • Voltages from 1.8 to 56V • Current up to 60 Amps • Screw connection • Worldwide approvals & CB report • Medical Approval Option |
Original | ||||
| vega | Vega Customer Applications Manual Section 8 - EMC Installation notes Connecting Vega to Maximise EMC performance. Good EMC performance comes by carefully considering the installation of the power supply. Installation without due consideration to cable/PCB layout can lead to current carrying loops that can radiate noise into the system |
Original | ||||
| Applications Manual Vega Series Power Supply 3055 | Applications Manual Vega Series Power Supply 3055 Del Sol Blvd. San Diego, CA 92154 Phone: (619) 575-4400 Fax: (619) 429-1011 Rev: Date: A3 October 2003 Vega Customer Applications Manual Table of Contents Table of Contents… 2 |
Original | ||||
| vega 650 | Vega 650 Handbook Part Number 17137 Input Parameters NOMINAL INPUT VOLTAGE RANGE 100 - 240VAC MAX. INPUT VOLTAGE RANGE 90-264VAC INPUT FREQUENCY 47-63Hz MAXIMUM INPUT CURRENT 11 A AC INRUSH CURRENT <40 AMPS Customer Air Cooling (option C): The following method must be used for determining the safe operation of PSUs when C option |
Original | ||||
|
|
||||||
| vega | Vega Customer Applications Manual Section 1 - Connection Connecting Vega to the input supply. The AC input connection is situated adjacent to the cooling fan inlet as shown above. The faston tabs are tin plated 6.3 x 0.8mm at 9mm centres. Connection is made using insulated 6.35mm 'faston' connectors rated at |
Original | ||||
| vega | Vega VAR Version Multiple Output Modular Power Supply 450W & 650W Output Power Levels Monitoring Signals 1 - 10 Outputs Wide Range Output Adjustment Output Voltages From 1.5V - 62 V Input Connection Options Medical UL2601/IEC601 Approvals |
Original | ||||
| vega | Vega Series 450 to 900W Multiple Output Modular Power Supply 1-10 Wide Range Outputs With Adjustment Forward/Reverse/Low Noise/System Air Cooling Output Voltages From 0.5V - 62V 48VDC Input Option Medical Approval Options MIL-STD-810 Shock and Vibration |
Original | ||||
| Vega Series Multiple Output Modular Power Supply | Vega Series Multiple Output Modular Power Supply 450W, 650W & 900W Output Power Levels Industry Leading 8W / cu. in Power Density* Monitoring Signals Forward/Reverse/Low Noise/System Air Cooling 1-10 Wide Range Outputs With Adjustment |
Original | ||||
| vega | Vega VAR Series 450 to 900W Multiple Output Modular Power Supply Input Connection Options 1-10 Wide Range Outputs With Adjustment Forward/Reverse/Low Noise/System Air Cooling Output Voltages From 1.8V - 62V Monitoring Signals Medical Approval Option |
Original | ||||
| Vega Series 450 to 900W Multiple Output Modular | Vega Series 450 to 900W Multiple Output Modular Power Supply Industry Leading 8W / cu. in Power Density* Monitoring Signals Forward/Reverse/Low Noise/System Air Cooling 1-10 Wide Range Outputs With Adjustment Output Voltages From 0.25V - 62V |
Original | ||||
| vega | Vega-Lite 550 to 900W Multiple Output Modular Power Supply Suitable for higher volume applications 1-10 Wide Range Outputs With Adjustment Output Voltages From 1.8 - 56V Medical Approval Options MIL-STD-810 Shock and Vibration Ve g a F e a t u r e s a n d B e n e f i t s |
Original | ||||
| Vega Customer Applications Manual Section 2 - | Vega Customer Applications Manual Section 2 - Analogue Primary Options OPTION E, EV, F, FV, EW, FW The Analogue primary option is a factory fitted option board which provides the following functions: 1) Warning the AC input has been lost or that the converter has overheated. |
Original | ||||
| nv350 | NV350 Series 350W Multiple Output Modular Power Supplies Features and Benefits Feature 1U Form Factor Up to 90% Efficient Active Power Factor Correction Universal Input (90 - 264VAC) 1 - 6 Outputs No Minimum Loads Medical Approvals |
Original | ||||
| vega | Vega Customer Applications Manual Section 10 - Combining Modules Combined or seriesed Modules BB@, CC@, DD@, EE@, HH@, LL@ The above modules are factory seriesed Vega modules to increase the range of output voltages and currents that are available. Eg CC@ are 2 C modules seriesed together, where @ is the No. of turns. Factory fitted |
Original | ||||