L4981 DATASHEET Search Results
Documents mentioning L4981 DATASHEET
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| l4981a | APPLICATION NOTE A 500W HIGH POWER FACTOR WITH THE L4981A CONTINUOUS MODE IC The widespread use of passive AC/DC off-line converters causes low power factor and high line current harmonic distortion. To reduce these phenomena and to comply with relevant regulatory |
Original | ||||
| APPLICATION NOTE A 500W HIGH POWER FACTOR WITH | APPLICATION NOTE A 500W HIGH POWER FACTOR WITH THE L4981A CONTINUOUS MODE IC The widespread use of passive AC/DC off-line converters causes low power factor and high line current harmonic distortion. To reduce these phenomena and to comply with relevant regulatory |
Original | ||||
| an827 | AN827 APPLICATION NOTE A 500W HIGH POWER FACTOR WITH THE L4981A CONTINUOUS MODE IC The widespread use of passive AC/DC off-line converters causes low power factor and high line current harmonic distortion. To reduce these phenomena and to comply with relevant regulatory agency requirements , designers are employing active power factor correction in their off-line SMPS applications. This |
Original | ||||
| l4981a | APPLICATION NOTE A 500W HIGH POWER FACTOR WITH THE L4981A CONTINUOUS MODE IC The widespread use of passive AC/DC off-line converters causes low power factor and high line current harmonic distortion. To reduce these phenomena and to comply with relevant regulatory |
Original | ||||
| an2530 | AN2530 Application note Solution for 150 W half bridge resonant DC-DC converter Introduction This application note describes a 150 W Half bridge resonant DC-DC converter. This type of SMPS is highly attractive due to its high achievable efficiency, very low noise and compact |
Original | ||||
| an1616 | AN1616 APPLICATION NOTE THD-OPTIMIZER CIRCUITS FOR PFC PRE-REGULATORS by Claudio Adragna Although THD (Total Harmonic Distortion) is not explicitly considered in IEC 61000-3-2 standards, neither it needs to be very low in order for a piece of equipment to get the presumption of conformity, however it has become established to require an ultra-low THD in some applications such as electronic |
Original | ||||
| APPLICATION NOTE P.F.C. APPLICATION IDEAS USING | APPLICATION NOTE P.F.C. APPLICATION IDEAS USING MAINS TRANSFORMER The typical PFC boost scheme is mainly suggested for off-line applications, with the galvanic insulation located in the downstream converter side. There are some industrial and consumer applications in which the galvanic insulation is provided by |
Original | ||||
| APPLICATION NOTE P.F.C. APPLICATION IDEAS USING | APPLICATION NOTE P.F.C. APPLICATION IDEAS USING MAINS TRANSFORMER The typical PFC boost scheme is mainly suggested for off-line applications, with the galvanic insulation located in the downstream converter side. There are some industrial and consumer applications in which the galvanic insulation is provided by |
Original | ||||
| an825 | AN825 APPLICATION NOTE P.F.C. APPLICATION IDEAS USING MAINS TRANSFORMER The typical PFC boost scheme is mainly suggested for off-line applications, with the galvanic insulation located in the downstream converter side. There are some industrial and consumer applications in which the galvanic insulation is provided by |
Original | ||||
| APPLICATION NOTE P.F.C. APPLICATION IDEAS USING | APPLICATION NOTE P.F.C. APPLICATION IDEAS USING MAINS TRANSFORMER The typical PFC boost scheme is mainly suggested for off-line applications, with the galvanic insulation located in the downstream converter side. There are some industrial and consumer applications in which the galvanic insulation is provided by |
Original | ||||
| an825 | AN825 APPLICATION NOTE ® P.F.C. APPLICATION IDEAS USING MAINS TRANSFORMER The typical PFC boost scheme is mainly suggested for off-line applications, with the galvanic insulation located in the downstream converter side. There are some industrial and consumer applications in which the galvanic insulation is provided by |
Original | ||||
| an2649 | AN2649 Application note A power factor corrector with MDmeshTM II and SiC diode Introduction The electrical and thermal performances of switching converters are strongly influenced by the behavior of the switching devices. Modern power devices design requires a trade-off in |
Original | ||||
| an2951 | AN2951 Application note 3 kW fixed-off-time (FOT) power factor correction Introduction In recent years, regulation in terms of electrical efficiency, electromagnetic noise, and reliability of the electronic apparatus, in all the application fields, are pushing to use power |
Original | ||||
| an3027 | AN3027 Application note How to design a transition-mode PFC pre-regulator with the L6563S and L6563H Introduction The transition-mode (TM) technique is widely used for power factor correction in low and middle power applications such as lamp ballasts, high-end adapters, flatscreen TVs and |
Original | ||||
|
|
||||||
| an3027 | AN3027 Application note How to design a transition-mode PFC pre-regulator with the L6563S and L6563H Introduction The transition-mode (TM) technique is widely used for power factor correction in low and middle power applications such as lamp ballasts, high-end adapters, flatscreen TVs and |
Original | ||||
| an3027 | AN3027 Application note How to design a transition-mode PFC pre-regulator with the L6563S and L6563H Introduction The transition-mode (TM) technique is widely used for power factor correction in low and middle power applications such as lamp ballasts, high-end adapters, flatscreen TVs and |
Original | ||||