KIRDC0005EA Search Results
KIRDC0005EA Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
| 
 Contextual Info: INFRARED DETECTOR InSb photoconductive detector P6606 series Thermoelectrically cooled detectors capable of long-term measurements Features Applications l Thermoelectric cooling ensures high speed and high l Environment measurements gas analysis, etc. sensitivity up to 6.5 µm.  | 
 Original  | 
P6606 A3179 A3179-01 A3179-04 C1103-05 C1103-07 SE-171 KIRD1026E06 | |
P3257-30
Abstract: Photoconductive Infrared Sensor 81 110 thermistor p2750 um 741 A3179-01 A3179-04 C1103-05 C1103-07 C5185-01 
  | 
 Original  | 
P3257/P3981/P2750 SE-171 KIRD1025E10 P3257-30 Photoconductive Infrared Sensor 81 110 thermistor p2750 um 741 A3179-01 A3179-04 C1103-05 C1103-07 C5185-01 | |
C5185
Abstract: A3179 A3179-01 A3179-04 C1103-05 C1103-07 P4631-03 P6606 P6606-110 P6606-210 
  | 
 Original  | 
P6606 A3179 A3179-01 A3179-04 C1103-05 C1103-07 SE-171 KIRD1026E07 C5185 A3179 A3179-01 A3179-04 C1103-05 C1103-07 P4631-03 P6606-110 P6606-210 | |
gas detector
Abstract: radiation detector photoconductive InSb C1103-05 IR-Laser A3179 A3179-01 A3179-04 C1103-07 C5185 
  | 
 Original  | 
P6606 A3179 A3179-01 A3179-04 C1103-05 C1103-07 SE-171 KIRD1026E04 gas detector radiation detector photoconductive InSb C1103-05 IR-Laser A3179 A3179-01 A3179-04 C1103-07 C5185 | |
| 
 Contextual Info: INFRARED DETECTOR InSb photoconductive detector P6606 series Thermoelectrically cooled detectors capable of long-term measurements Features Applications l Thermoelectric cooling ensures high speed and high l Environment measurements gas analysis, etc. sensitivity up to 6.5 µm.  | 
 Original  | 
P6606 A3179-01 A3179-04 C1103-05 C1103-07 C5185 SE-171 KIRD1026E08 | |
| 
 Contextual Info: PbS Photoconductive Detectors Easy-to-use photoconductive detec tors with high responsivity over 3 um • Operates at room temperature Since PbS cells operate stably at room tem perature, they are used in a w ide range o f applications such as radiation therm om eters and flam e  | 
 OCR Scan  | 
KIRDB0048EA KIRDB0049EA KIRDB0050EA KIRDC0005EA | |
C4696
Abstract: gas sensor CO2 with thermistor photoconductive MCT C3871 C1103 C1103-05 optical thermometer cdte CO2 GAS SENSOR co2 sensor circuit 
  | 
 Original  | 
P3257/P3981/P2750 SE-171 KIRD1025E05 C4696 gas sensor CO2 with thermistor photoconductive MCT C3871 C1103 C1103-05 optical thermometer cdte CO2 GAS SENSOR co2 sensor circuit | |
| 
 Contextual Info: INFRARED DETECTOR MCT photoconductive detector P3257/P3981/P2750 series Non-cooled type and TE-cooled type suitable for long, continuous operation Features Applications l Choice of spectral response up to 12 µm The band gap can be adjusted by controlling the composition  | 
 Original  | 
P3257/P3981/P2750 SE-171 KIRD1025E08 | |
| 
 Contextual Info: INFRARED DETECTOR MCT photoconductive detector P3257/P3981/P2750 series Non-cooled type and TE-cooled type suitable for long, continuous operation Features Applications l Choice of spectral response up to 12 µm The band gap can be adjusted by controlling the composition  | 
 Original  | 
P3257/P3981/P2750 SE-171 KIRD1025E07 | |
solnaContextual Info: INFRARED DETECTOR MCT photoconductive detector P3257/P3981/P2750 series Non-cooled type and TE-cooled type suitable for long, continuous operation Features Applications l Choice of spectral response up to 12 µm The band gap can be adjusted by controlling the composition  | 
 Original  | 
P3257/P3981/P2750 SE-171 KIRD1025E09 solna | |
| 
 Contextual Info: INFRARED DETECTOR MCT photoconductive detector P3257/P3981/P2750 series Non-cooled type and TE-cooled type suitable for long, continuous operation Features Applications l Choice of spectral response up to 12 µm The band gap can be adjusted by controlling the composition  | 
 Original  | 
P3257/P3981/P2750 SE-171 KIRD1025E04 | |
A3179-04Contextual Info: INFRARED DETECTOR InSb photoconductive detector P6606 series Thermoelectrically cooled detectors capable of long-term measurements Features Applications l Thermoelectric cooling ensures high speed and high l Environment measurements gas analysis, etc. sensitivity up to 6.5 µm.  | 
 Original  | 
P6606 A3179 A3179-01 A3179-04 C1103-05 C1103-07 SE-171 KIRD1026E03 | |
| 
 Contextual Info: INFRARED DETECTOR MCT photoconductive detector P3257/P3981/P2750 series Non-cooled type and TE-cooled type suitable for long, continuous operation Features Applications l Choice of spectral response up to 12 µm The band gap can be adjusted by controlling the composition  | 
 Original  | 
P3257/P3981/P2750 SE-171 KIRD1025E09 | |
| 
 Contextual Info: INFRARED DETECTOR InSb photoconductive detector P6606 series Thermoelectrically cooled detectors capable of long-term measurements Features Applications l Thermoelectric cooling ensures high speed and high l Environment measurements gas analysis, etc. sensitivity up to 6.5 µm.  | 
 Original  | 
P6606 A3179 A3179-01 A3179-04 C1103-05 C1103-07one: SE-171 KIRD1026E05 | |
| 
 | 
|||
| 
 Contextual Info: MCT HgCdTe Photoconductive Detectors (TE-cooled Types) Thermoelectric cooling assures stable operation over extended time periods • Choice of spectral response T he band gap o f H gC dT e can be m odified by controlling the com po sition ratio o f H gT e and C dT e. U tilizing this fact, various types are  | 
 OCR Scan  | 
KIRDC0006EA | |