Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    KA BREAKER Search Results

    KA BREAKER Result Highlights (3)

    Part ECAD Model Manufacturer Description Download Buy
    LM74900QRGERQ1
    Texas Instruments Automotive ideal diode with circuit breaker, under- and overvoltage protection with fault output 24-VQFN -40 to 125 Visit Texas Instruments
    LM74930QRGERQ1
    Texas Instruments Automotive 3-V to 65-V surge stopper with circuit breaker and overvoltage protection 24-VQFN -40 to 125 Visit Texas Instruments
    LM74910QRGERQ1
    Texas Instruments Automotive ideal diode with circuit breaker, 200-kHz ACS and under- and overvoltage protection 24-VQFN -40 to 125 Visit Texas Instruments

    KA BREAKER Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    FAZ-C10

    Abstract: IEC 60947-2 FAZ-C3 FAZ-C16 FAZ-C63 FAZ-C32 FAZ-D20 60947-2 circuit-breakers faz D20
    Contextual Info: I12_006-007_b_G.fm Seite 6 Donnerstag, 16. September 2004 12:28 12 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA IEC/EN 60947-2 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures


    Original
    HPL0211-2004/2005 D-53115 HPL-C2006G FAZ-C10 IEC 60947-2 FAZ-C3 FAZ-C16 FAZ-C63 FAZ-C32 FAZ-D20 60947-2 circuit-breakers faz D20 PDF

    IEC 60947-2

    Abstract: FAZ-B6 IEC/EN 60947 FAZ-B16 60947-2 IEC/EN 60947-2 Miniature fuse 2.HS FAZ-B40 B16 circuit breaker
    Contextual Info: I12_004-005_b_G.fm Seite 4 Donnerstag, 16. September 2004 12:28 12 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA IEC/EN 60947-2 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures


    Original
    HPL0211-2004/2005 D-53115 HPL-C2006G IEC 60947-2 FAZ-B6 IEC/EN 60947 FAZ-B16 60947-2 IEC/EN 60947-2 Miniature fuse 2.HS FAZ-B40 B16 circuit breaker PDF

    X 222 611 01

    Abstract: UL 486 torque values Zbf 34 IEC-60664
    Contextual Info: Thermal-Magnetic Circuit Breaker 4220-T. Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 5 kA , EN/IEC 60934 (6kA) and UL 1077 (5 kA). With toggle actuation, positively trip-free mechanism, a


    Original
    4220-T. X 222 611 01 UL 486 torque values Zbf 34 IEC-60664 PDF

    Contextual Info: Thermal-Magnetic Circuit Breaker 4220-T. Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 5 kA , EN/IEC 60934 (6kA) and UL 1077 (5 kA). With toggle actuation, positively trip-free mechanism, a


    Original
    4220-T. PDF

    FAZ-C10

    Abstract: FAZ-C16 IEC 60947-2 FAZ-C63 FAZ-C6/1 FAZ-C2 IEC/EN 60947-2 FAZ-C3 mcb C20 FAZ-C25
    Contextual Info: I12_006-007_b_G.fm Seite 6 Donnerstag, 16. September 2004 12:28 12 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA IEC/EN 60947-2 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures


    Original
    HPL0211-2004/2005 D-53115 HPL-C2006GB-INT FAZ-C10 FAZ-C16 IEC 60947-2 FAZ-C63 FAZ-C6/1 FAZ-C2 IEC/EN 60947-2 FAZ-C3 mcb C20 FAZ-C25 PDF

    Contextual Info: Thermal-Magnetic Circuit Breaker 4220-T. Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 5 kA , EN/IEC 60934 (6kA) and UL 1077 (5 kA). With toggle actuation, positively trip-free mechanism, a


    Original
    4220-T. PDF

    QPL-W-F-1814

    Contextual Info: POWR-GARD Fuse Datasheet UL Class L KLPC Series powr-pro ® FUSES 600 VAC • Time-Delay • 200-6000 Amperes Specifications Voltage Ratings: AC: 600 V DC: 480 V Interrupting Ratings: AC: 200 kA rms symmetrical 300 kA rms symmetrical Littelfuse self-certified


    Original
    E81895) E71611) LR29862) QPL-W-F-1814) QPL-W-F-1814 PDF

    Contextual Info: POWR-GARD Fuse Datasheet UL Class L KLLU series FUSES 600 VAC • Time-Delay • 601-4000 Amperes Specifications Voltage Ratings: Interrupting Ratings: Ampere Range: Approvals: AC: 600 V DC: 300 V AC: 200 kA DC: 20 kA 601–4000 A Standard 248-10, Class L


    Original
    E81895) LR29862) KLLU601 PDF

    C60H Circuit Breakers Catalogue

    Abstract: c60h tripping curves C60H CIRCUIT-BREAKERS C60H IEC60898 26160 24987 c60h 2p 25159 90090E
    Contextual Info: Protect Circuit protection C60H circuit breakers B, C and D curves IEC 60898: 10000 A , IEC 60947-2: 15 kA Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of circuits against overload currents


    Original
    90090E C60H Circuit Breakers Catalogue c60h tripping curves C60H CIRCUIT-BREAKERS C60H IEC60898 26160 24987 c60h 2p 25159 PDF

    C60N

    Abstract: C60N 24396 C60N c C60n Circuit Breakers Catalogue c60n tripping curves IEC60898 C60N 24334 vigi C60N C60N 3P 24334
    Contextual Info: Protect Circuit protection C60N circuit breakers B, C and D curves IEC 60898: 6000 A , IEC 60947-2: 10 kA Function b The circuit-breakers combine the following functions: v protection of circuits against short-circuit currents v protection of circuits against overload currents


    Original
    90078E C60N C60N 24396 C60N c C60n Circuit Breakers Catalogue c60n tripping curves IEC60898 C60N 24334 vigi C60N C60N 3P 24334 PDF

    10 kw schematic induction heating

    Abstract: shunt release contact mpcb IEC 947-2 VDE 0660 VDE 0660 iec 947-2 reversible d.c. motors wiring schematic rotary operating mechanism 15 KW induction motor 440v 3phase VDE 0106 1010 shunt release coil function 3-phase induction motors test results
    Contextual Info: Motor Protection Circuit Breaker MPCB J7MN ) MPCB system (motor protection CLASS 10) • Rotary and switch types • Rated operational current = 12 A, 25 A and 50 A • Switching capacity up to 12.5 A = 100 kA/400 V • Fixed short-circuit release = 13 x Iu


    Original
    kA/400 10 kw schematic induction heating shunt release contact mpcb IEC 947-2 VDE 0660 VDE 0660 iec 947-2 reversible d.c. motors wiring schematic rotary operating mechanism 15 KW induction motor 440v 3phase VDE 0106 1010 shunt release coil function 3-phase induction motors test results PDF

    J7MN-3P-10

    Abstract: J77MN-11F J7KNG-40 J77MN-PF-3R J77MN-U J7MN-3R-E63 J7MN-3P-E63 J75-BTC-50-E J7MN-3P-32 J7MN-3R-22
    Contextual Info: Motor Protection Circuit Breaker J7MN MPCB system • Rotary and switch types • Rated operational current 32 A, 63 A and 100 A • Switching capacity up to 100 kA/400 V • Fixed short-circuit release = 13 x Iu • Overload release adjustable 0.65 - 1 x Iu


    Original
    kA/400 J77MN-PF J77MN-DC J08E-EN-02 J7MN-3P-10 J77MN-11F J7KNG-40 J77MN-PF-3R J77MN-U J7MN-3R-E63 J7MN-3P-E63 J75-BTC-50-E J7MN-3P-32 J7MN-3R-22 PDF

    schematic diagram DC circuit breaker

    Abstract: IEC 947-2 VDE 0660 J7MN-25-1 schematic diagram ac circuit breaker VDE 0660 u MINIATURE CIRCUIT BREAKER Breaking capacity limit switch VDE 0660 IEC 60947-4-1 J7KN-10-10 J7MN
    Contextual Info: Motor Protection Circuit Breaker ker MPCB B) ) MPCB system (motor protection CLASS LASS 10) • Rotary and switch types • Rated operational current = 12 A, 25 A and 50 A • Switching capacity up to 12.5 A = 100 kA/400 V • Fixed short-circuit release = 13 x Iu


    Original
    kA/400 J74MN-P12 J74MN-P25 J74MN-PF12 J74MN-DC J74MN-L3- J7MN-12 J7MN-25, J74MN-TC12 J74MN-TC25 schematic diagram DC circuit breaker IEC 947-2 VDE 0660 J7MN-25-1 schematic diagram ac circuit breaker VDE 0660 u MINIATURE CIRCUIT BREAKER Breaking capacity limit switch VDE 0660 IEC 60947-4-1 J7KN-10-10 J7MN PDF

    DILM185

    Abstract: DILM225 NZMN2-M200 Moeller DILM 22 IEC 60947-4-1 EN 60947-4-1 DILM185/22 IEC/EN 60947 VDE 0660 fuse breaker VDE 0660
    Contextual Info: Type: NZMN2−M200 Article No.: 265725 Sales text Circuit−breaker 3p 200A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 160.200 Short−circuit release 1600.2500


    Original
    NZMN2-M200 DILM185/22( DILM225/22( D-53115 HPL-C2007G DILM185 DILM225 NZMN2-M200 Moeller DILM 22 IEC 60947-4-1 EN 60947-4-1 DILM185/22 IEC/EN 60947 VDE 0660 fuse breaker VDE 0660 PDF

    5SY6

    Abstract: siemens VDE 0641
    Contextual Info: Siemens AG 2008 5SY6 Miniature Circuit Breakers High-capacity range, 6 kA • Application • Un: 230/400 V, 50-60 Hz, applicable in networks up to 250/440 V AC, 60 V DC per pole • Standards EN 60898, VDE 0641 Part 11 , IEC 60898 • Supplementary components can be retrofitted


    Original
    PDF

    kcc cl-150

    Abstract: 3PRA 20 3PRA 60 5a 20SP 012 KRPC-3000 buss fusetron fusetron dual element FUSE FNM-6 IR 200 A mcm 750 100a 15sp 012 J60400-1CR
    Contextual Info: General Data — Selection Chart Bussmann Buss Fuse Selection Chart 600 Volts or Less Circuit Load Ampere Fuse Rating Type Symbol Voltage Rating (a-c) Class Interrupting Rating (KA) Remarks All-purpose fuses. Unequaled for combined short-circuit and overload protection.


    Original
    01-6000A) kcc cl-150 3PRA 20 3PRA 60 5a 20SP 012 KRPC-3000 buss fusetron fusetron dual element FUSE FNM-6 IR 200 A mcm 750 100a 15sp 012 J60400-1CR PDF

    Contextual Info: VAL-SQ SI… 25 and 40 kA Surge Protective Device for small installation protection TRABTECH Data Sheet 2532_en_A 1 PHOENIX CONTACT - 07/2008 Description 2 The VAL-SQ SI… Surge Protective Device SPD provides surge protection in a compact, affordable package.


    Original
    40-3C-600 PDF

    NZMN1-M63

    Abstract: IEC/EN 60947-4-1 IEC/EN 60947 dilm65 EN 60947-4-1 IEC 60947-4-1 circuit breaker VDE 0660 motor protective relays MOELLER IEC 60947 VDE 0660
    Contextual Info: Type: NZMN1−M63 Article No.: 265720 Sales text Circuit−breaker 3p 63A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 50.63 Short−circuit release 504.882 Contactor type “1” coordination


    Original
    NZMN1-M63 DILM65( DILM80( D-53115 HPL-C2007G NZMN1-M63 IEC/EN 60947-4-1 IEC/EN 60947 dilm65 EN 60947-4-1 IEC 60947-4-1 circuit breaker VDE 0660 motor protective relays MOELLER IEC 60947 VDE 0660 PDF

    NZMN1-M80

    Abstract: IEC 60947-4-1 EN 60947-4-1 IEC/EN 60947 IEC/EN 60947-4-1 VDE 0660 motor protective relays MOELLER moeller DILM80 dilm80 IEC 60947 VDE 0660 NFEN60947-2
    Contextual Info: Type: NZMN1−M80 Article No.: 265721 Sales text Circuit−breaker 3p 80A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 63.80 Short−circuit release 640.1120 Contactor type “1” coordination


    Original
    NZMN1-M80 DILM80( D-53115 HPL-C2007G NZMN1-M80 IEC 60947-4-1 EN 60947-4-1 IEC/EN 60947 IEC/EN 60947-4-1 VDE 0660 motor protective relays MOELLER moeller DILM80 dilm80 IEC 60947 VDE 0660 NFEN60947-2 PDF

    NZMN1-M100

    Abstract: Moeller DILM95 DILM115 IEC/EN 60947-4-1 motor protective relays MOELLER IEC/EN 60947 VDE 0660 IEC 60947-4-1 motor protective MOELLER IEC 60947 VDE 0660 NFEN60947-2
    Contextual Info: Type: NZMN1−M100 Article No.: 265722 Sales text Circuit−breaker 3p 100A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 80.100 Short−circuit release 800.1250 Contactor type “1” coordination


    Original
    NZMN1-M100 DILM95( DILM115( D-53115 HPL-C2007G NZMN1-M100 Moeller DILM95 DILM115 IEC/EN 60947-4-1 motor protective relays MOELLER IEC/EN 60947 VDE 0660 IEC 60947-4-1 motor protective MOELLER IEC 60947 VDE 0660 NFEN60947-2 PDF

    Contextual Info: Data sheet – – High short-circuit breaking capability of 25 kA over the complete rated current range – – High energy-limiting capacity by current-limiting selectivity – – Suitable for selective overcurrent protection at the meter mounting board and in general-purpose electric main


    Original
    D0203 08/12-pdf) PDF

    IEC 60269-2-1

    Abstract: fuse iec 60269 E302753 MF114GG69V2000
    Contextual Info: General Purpose Fuses IEC General Purpose Fuses IEC Masterfuse gG 690V Highlights • • • • • High ratings 1250 to 2500 A gG operating fuse for 690V AC Nominal Conformity with IEC 60269 1 and 2 Dimensional according section V on IEC 60269-2-1 Breaking capacity 690V 160 KA – 50Hz


    Original
    MF76GG69V1250 MF89GG69V1600 MF114GG69V2000 MF127GG69V2500 146mm) 160mm) 181mm) GPEU60 IEC 60269-2-1 fuse iec 60269 E302753 PDF

    Contextual Info: General Purpose Fuses IEC General Purpose Fuses IEC Masterfuse gG 690V Highlights • • • • • High ratings 1250 to 2500 A gG operating fuse for 690V AC Nominal Conformity with IEC 60269 1 and 2 Dimensional according section V on IEC 60269-2-1 Breaking capacity 690V 160 KA – 50Hz


    Original
    146mm) GPEU61 GPEU62 PDF

    cd-rom motor driver

    Abstract: opamp hysteresis 12v amp diagram 200S KA3012D built ac servo drive circuit cdrom drive CIRCUIT DIAGRAM "sled motor"
    Contextual Info: KA3012D CD-ROM PRODUCTS 4-CH MOTOR DRIVER 28-SSOPH-375 The KA 3012D is a m onolithic integrated circuit, and suitable for 4-CH m otor d river w hich drives sled motor, loading motor, focus & tracking actuator of C D-RO M system and built in op-am p w hich can receive digital


    OCR Scan
    KA3012D KA3012D 28-SStains cd-rom motor driver opamp hysteresis 12v amp diagram 200S built ac servo drive circuit cdrom drive CIRCUIT DIAGRAM "sled motor" PDF