Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ISOLATION TRANSFO Search Results

    ISOLATION TRANSFO Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DCL540C01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: Low Datasheet
    DCL540D01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: High Datasheet
    DCL540H01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: High / Output enable Datasheet
    DCL541L01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Output enable Datasheet
    DCL541A01
    Toshiba Electronic Devices & Storage Corporation Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Input disable Datasheet
    SF Impression Pixel

    ISOLATION TRANSFO Price and Stock

    API Delevan

    API Delevan CM6296R-253

    Common Mode Chokes / Filters 25uH 25% .007ohm Choke/Isolation SMT
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI CM6296R-253 Bulk 250
    • 1 -
    • 10 -
    • 100 -
    • 1000 $12.36
    • 10000 $12.23
    Buy Now

    API Delevan CM6296-105 50-PKG-BULK

    Common Mode Chokes / Filters 1000uH 25% .025ohm Choke/Isolation SMT
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TTI CM6296-105 50-PKG-BULK Bag 250
    • 1 -
    • 10 -
    • 100 -
    • 1000 $12.36
    • 10000 $12.23
    Buy Now

    Documents mentioning ISOLATION TRANSFO

    Document Partial File Text Tags Type PDF
    SMD 10/100 Isolation Modules SMD 10/100 Isolation
    SMD 10/100 Isolation Modules SMD 10/100 Isolation Modules HALO Electronics has developed this standard series of 10/100 Isolation Modules to specifically address the isolation, insertion loss and return loss requirements of IEEE 802.3u. All HALO isolation transformers are UL/EN60950 and DEMKO recognized.
    Original PDF
    Maxim > App Notes > INTERFACE CIRCUITS PROTECTION
    Maxim > App Notes > INTERFACE CIRCUITS PROTECTION AND ISOLATION Keywords: RS-485, rs485, full duplex, isolated, isolation, isolated circuits, isolated lines, 250kbaud, 2.5Mbaud, 250 kilobaud, 2.5 megabaud, bi-directional, 1600V isolation, 2000V isolation, transformer coupled, opto
    Original PDF
    APPLICATION NOTES Modem Isolation Transformers
    APPLICATION NOTES Modem Isolation Transformers Modem Isolation Transformers Basic Function of the Modem Isolation Transformer Modem Isolation Transform ers (M IT’s) provide three essential fu n ctio n s w ithin the te le co m m u nica tio n s network. First, the MIT must provide electrical isolation
    OCR Scan PDF
    ISOLATION: DIGITAL Digital/Logic Isolators # CH
    ISOLATION: DIGITAL Digital/Logic Isolators # CH MODEL NUMBER Power Supply Input/Output Vss Side Volts mA Transformer Isolation AD260A 5 AD260B 5 AD261A 5 AD261B 5 +5V +5V +5V +5V 18/18 @ 10MHz 18/18 @ 10MHz 18/18 @ 10MHz 18/18 @ 10MHz Operating Isolation Isolation
    Original PDF
    PRODUCT INFORMATION IAD110P Circuits Division
    PRODUCT INFORMATION IAD110P Circuits Division CPCJare CORPORATION ODUCT OFFERING Advanced Magnetic Products Circuits Products Modem Isolation Transformers Encapsulated Modem Isolation Transformers Surface Mount Modem Isolation Transformers Single Pole OptoMOS® Relays
    OCR Scan PDF
    PRODUCT INFORMATION CYG22XX Series Circuits
    PRODUCT INFORMATION CYG22XX Series Circuits Division CPCJare CORPORATION OFFERING Advanced Magnetic Products Circuits Products Modem Isolation Transformers Encapsulated Modem Isolation Transformers Surface Mount Modem Isolation Transformers Single Pole OptoMOS® Relays
    OCR Scan PDF
    auto transformers
    1025-2012:QuarkCatalogTempNew 8/28/12 2:06 PM Page 1025 11 Auto,Isolation and Class 2 Transformers TEST & MEASUREMENT Auto/Step-Up, Step-Down and Isolation Transformers D D H H MW MD W MWW Style C Auto transformers have one winding that is tapped to achieve specific output voltage. They provide no electrical isolation in a circuit. Auto transformers are typically smaller than their isolation equivalent. Isolation transformers have two separate windings
    Original PDF
    Isolation (Plug In) 171 SERIES LINE ISOLATION
    Isolation (Plug In) 171 SERIES LINE ISOLATION PLUG & RECEPTACLE TRANSFORMERS (115V to 115V) • Primary 115VAC, 50/60 Hz., Secondary 115VAC • Provides circuit isolation. • Electrostatic shield between primary & secondary. • Standard 3-wire, grounded plug & receptacle.
    Original PDF
    Isolation (Plug In) 171 SERIES LINE ISOLATION
    Isolation (Plug In) 171 SERIES LINE ISOLATION PLUG & RECEPTACLE TRANSFORMERS (115V to 115V) • Primary 115VAC, 50/60 Hz., Secondary 115VAC • Provides circuit isolation. • Electrostatic shield between primary & secondary. • Standard 3-wire, grounded plug & receptacle.
    Original PDF
    ts7022a
    Bothhand USA. e-mail: sales@bothhandusa.com http://www.bothhandusa.com 10 BASE-T ISOLATION TRANSFORMER Pag1/1 P/N:TS7022A DATA SHEET Feature 16 PIN SMD isolation modules to meet the isolation and impedance matching Requirement of IEEE 802.3 for 10 BASE-T .
    Original PDF
    6 Pin, 3kVrms DC/DC Converter Isolation Modules
    6 Pin, 3kVrms DC/DC Converter Isolation Modules Designed for Texas Instruments ISO721 /722 6 Pin, 3kVrms DC/DC Converter Isolation Modules Designed for Texas Instruments ISO721 /722 The TGRTI-V6LF series of reinforced insulation transformers provides the isolation
    Original PDF
    CYG21XX Series i : = = E B m n = i i= CIRCUITS
    CYG21XX Series i : = = E B m n = i i= CIRCUITS DIVISION OFFERING Advanced Magnetic Products Circuits Products Modem Isolation Transform ers Encapsulated M odem Isolation Transform ers Surface M ount M odem Isolation Transform ers Single Pole OptoMOS® Relays
    OCR Scan PDF
    Line Straight Isolation - Plug In (171 Series)
    Line Straight Isolation - Plug In (171 Series) LINE ISOLATION PLUG & RECEPTACLE TRANSFORMERS (115V to 115V) • Primary 115VAC, 50/60 Hz., Secondary 115VAC • Provides circuit isolation. • Electrostatic shield between primary & secondary. • Hi-pot tested to 2 KV RMS.
    Original PDF
    Model 430 Isolation Transformer The Model 430 is
    Model 430 Isolation Transformer The Model 430 is a high-power, broad-band version of isolation transformer within ERI’s full line of isolation transformers.The Model 430 was developed for use across the entire commercial FM frequency band.The transformer’s
    Original PDF