ISO/IEC 11801 CAT 5 Search Results
ISO/IEC 11801 CAT 5 Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| MP-6ARJ45SNNB-050 |
|
Amphenol MP-6ARJ45SNNB-050 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - Blue 50ft | |||
| MP-6ARJ45SNNG-050 |
|
Amphenol MP-6ARJ45SNNG-050 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - Green 50ft | |||
| MP-6ARJ45SNNK-050 |
|
Amphenol MP-6ARJ45SNNK-050 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - Black 50ft | |||
| MP-6ARJ45SNNR-050 |
|
Amphenol MP-6ARJ45SNNR-050 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - Red 50ft | |||
| MP-6ARJ45SNNW-050 |
|
Amphenol MP-6ARJ45SNNW-050 CAT6A FTP Shielded Patch Cable (650-MHz) with Snagless CAT-6A Shielded RJ45 Connectors (10GbE Optimized) - White 50ft |
ISO/IEC 11801 CAT 5 Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
|
Contextual Info: HARTING PROFINET Type A Cable 4-wire, Cat. 5, PVC PROFINET Type A Cable 4-wire, Cat. 5, PVC Advantages • • • • General Suitable for PROFINET cabling Category 5 / Class D according to ISO/IEC 11801 respectively EN 50173 and ISO/IEC 24702 respectively EN 50173-3 |
Original |
10/100Mbit/s. dB/100m | |
|
Contextual Info: HARTING PROFINET Hybrid Cable, 4-wire + 4x1.5 , Cat. 5, FRNC PROFINET Hybrid Cable, 4-wire + 4x1.5, Cat. 5, FRNC Advantages • • • • General Suitable for PROFINET cabling Category 5 / Class D according to ISO/IEC 11801 respectively EN 50173-1 and ISO/IEC 24702 |
Original |
10/100Mbit/s | |
|
Contextual Info: HARTING PROFINET Type B Cable Outdoor, 4-wire, Cat. 5, PVC PROFINET Type B Cable Outdoor, 4-wire, Cat. 5, PVC Advantages • • • • General Suitable for PROFINET cabling Category 5 / Class D according to ISO/IEC 11801 respectively EN 50173-1 and ISO/IEC 24702 |
Original |
10/100Mbit/s. dB/100m | |
|
Contextual Info: HARTING PROFINET Type B Cable 4-wire Cat. 5 PVC PROFINET Type B Cable 4-wire, Cat. 5, PVC Advantages • • • • General Suitable for PROFINET cabling Category 5 / Class D according to ISO/IEC 11801 respectively EN 50173-1 and ISO/IEC 24702 respectively EN 50173-3 |
Original |
10/100Mbit/s. dB/100m | |
|
Contextual Info: HARTING PROFINET Type B Cable 4-wire, Cat. 5, PVC PROFINET Type B Cable 4-wire, Cat. 5, PVC Advantages • • • • General Suitable for PROFINET cabling Category 5 / Class D according to ISO/IEC 11801 respectively EN 50173-1 and ISO/IEC 24702 respectively EN 50173-3 |
Original |
10/100Mbit/s. dB/100m | |
|
Contextual Info: HARTING PROFINET Type C Cable 4-wire, Cat. 5, PUR PROFINET Type C Cable 4-wire, Cat. 5, PUR Advantages • • • • General Suitable for PROFINET cabling Category 5 / Class D according to ISO/IEC 11801 respectively EN 50173-1 and ISO/IEC 24702 respectively EN 50173-3 |
Original |
10/100Mbit/s. dB/100m | |
|
Contextual Info: HARTING Industrial Cable 8-wire Cat. 7 PUR Industrial Cable 8-wire, Cat. 7, PUR Advantages General Suitable for generic cabling Category 7 / Class F according ISO/IEC 11801 respectively EN 50173-1 especially for fixed installation Qualified for transmission up to |
Original |
10GigaBit 10GBase-T IEEE802 AWG23/1 600MHz | |
AWM STYLE 20276
Abstract: E47543-L AWM STYLE 20276 80C 30V AWM STYLE 20276 80 style 20276 E47543 awm 20276 AWM STYLE 20276 with ethernet AWM Style 20276 80 30V VW-1 harting hpr
|
Original |
1000Base-T IEEE802 27/7AWG 250MHz D-32339 D-32328 AWM STYLE 20276 E47543-L AWM STYLE 20276 80C 30V AWM STYLE 20276 80 style 20276 E47543 awm 20276 AWM STYLE 20276 with ethernet AWM Style 20276 80 30V VW-1 harting hpr | |
pimf cat 6 cable
Abstract: cat 6 ethernet cord harting cable CAT-6 ftp PIMF
|
Original |
1000Base-T IEEE802 27/7AWG 250MHz D-32339 D-32328 pimf cat 6 cable cat 6 ethernet cord harting cable CAT-6 ftp PIMF | |
ISO 11801 cat-5e
Abstract: UTP cat 6 cable DCD10713-00500DP RAL5012 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP IEC61156-6 UTP Cat 6
|
Original |
125MHz IEC61156-6; RAL7035 DCD10707-00500DP RAL3018 DCD10708-00500DP RAL6018 DCD10709-00500DP RAL1018 DCD10710-00500DP ISO 11801 cat-5e UTP cat 6 cable DCD10713-00500DP RAL5012 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP IEC61156-6 UTP Cat 6 | |
DRAKA
Abstract: 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP DCD10713-00500DP IEC61156-6 RAL7035 UTP cat 6 cable DCD10707-00500DP
|
Original |
125MHz IEC61156-6; RAL3018 DCD10708-00500DP RAL6018 DCD10709-00500DP RAL1018 DCD10710-00500DP RAL5012 DCD10711-00500DP DRAKA 100N DCD10709-00500DP DCD10710-00500DP DCD10711-00500DP DCD10713-00500DP IEC61156-6 RAL7035 UTP cat 6 cable DCD10707-00500DP | |
|
Contextual Info: HARTING Han 24 HPR Industrial enlarged Cable 8-wire, Cat. 5, PUR Industrial Cable 8-wire, Cat. 5, PUR Advantages General • Suitable for generic cabling Category 5 / Class D according ISO/IEC 11801 respectively EN 50173-1 especially for flexible installation patch cords |
Original |
1000Base-T IEEE802 26/7AWG 100MHz E96807 D-32339 D-32328 | |
|
Contextual Info: HARTING Industrial Cable 8-wire Cat. 6A PUR Industrial Cable 8-wire, Cat. 6A, PUR Advantages • • • • • • General Suitable for generic cabling Category 6A / Class EA according ISO/IEC 11801 respectively EN 50173-1 especially for flexible installation patch |
Original |
10GigaBit 10GBase-T IEEE802 AWG26/7 500MHz | |
sftpContextual Info: NEW CAT 6A CABLE ROHS compliant High reliability Cat 6A Ethernet cable & cordsets General construction A 4 pairs, 26 AWG, 100 Ohm SFTP round patch cable, designed to the ISO / IEC 11801 Category 6A requirements. The cable contains 4 twisted pairs individually shielded, cabled, double |
Original |
||
|
|
|||
|
Contextual Info: ROHS NEW CAT 6 CABLE compliant High reliability Cat 6 Ethernet cable & cordsets General construction A 4 pairs, 26 AWG, 100 Ohm SFTP round patch cable, designed to the ISO / IEC 11801 Category 6 requirements. The cable contains 4 twisted pairs individually shielded, cabled, double |
Original |
wit12 | |
VOL-OCK6-UB
Abstract: ISO 8877 VOL-OCK6-U VOL-OCK6 Volition RJ45 jack low profile
|
Original |
TIA/EIA-568 VOL-OCK6-UB ISO 8877 VOL-OCK6-U VOL-OCK6 Volition RJ45 jack low profile | |
RJF SFTP 5E 3050
Abstract: 190-038045-00 cat 5e rj45 ISO/IEC 11801 cat 5e, 6 kevlar 0624 CNC db 15 ISO/IEC 11801 RJ45 PLUG M3278
|
Original |
568-B, ns/100m 23db/100m RJF SFTP 5E 3050 190-038045-00 cat 5e rj45 ISO/IEC 11801 cat 5e, 6 kevlar 0624 CNC db 15 ISO/IEC 11801 RJ45 PLUG M3278 | |
TS68A
Abstract: TS68B RJ45 BOTTOM ENTRY VOL-OCK6-U RJ45 jack low profile
|
Original |
TIA/EIA-568 TS68A TS68B RJ45 BOTTOM ENTRY VOL-OCK6-U RJ45 jack low profile | |
ISO 11801 cat-5e foiled
Abstract: FTP 4X2X24 AWG CAT.5E 4x2x24 LSOH
|
Original |
4x2x24 99/003P) dB/100m dB/100m 71-15log 69-15log 69-20log 66-20log ISO 11801 cat-5e foiled FTP 4X2X24 AWG CAT.5E LSOH | |
ISO 8877
Abstract: RJ45 jack low profile T568A T568B RJ45 BOTTOM ENTRY VOL-OCK5E-U-AL
|
Original |
TIA/EIA-568 ISO 8877 RJ45 jack low profile T568A T568B RJ45 BOTTOM ENTRY VOL-OCK5E-U-AL | |
utp cat 5eContextual Info: Copper Data Cables Product Line: DX 21* UTP Cat. 5E – Enhanced 200 MHz Unshielded Twisted Pair 4x2x24 AWG CAT. 5E PVC or LSOH Sheath EN 50173 - ISO/IEC 11801 APPLICATION Horizontal and work area wiring cables for voice, video and high speed data transmission at frequency up to |
Original |
4x2x24 68-A-5 dB/100m 71-15log 69-15log 69-20log 66-20log 99/004P) utp cat 5e | |
28AVG
Abstract: CAT-6E ftp cable 40MM T568B 26AWG 26AWG RJ45
|
OCR Scan |
I50/IBC 28AVG 26AWG 015mm T568B 461ft; 110MM 150MM CAT-6E ftp cable 40MM 26AWG RJ45 | |
|
Contextual Info: Mating face RJ45 according to IEC 60603-7 93 > E Csfr X 'Han 3A Metal RJ45 Gigalink Cat. 6A - Transmission properties in accordance with ISO/IEC 11801: Class E Protection level: IP67/65 - Temperature range: -20°C . +80°C M20x1.5 metal cable clamp Loading-Plan |
OCR Scan |
IP67/65 M20x1 D-32339 094571515XX 100155415/UGD/012/B | |
|
Contextual Info: Datasheet - Page 1 DIGITUS Desktop CAT 6, Class E Patch Panel, shielded DN-91608SD 4016032241584 DIGITUS Desktop CAT 6 Patch Panel, shielded CLass E, 8-port RJ45, 8P8C, LSA Color black RAL 9005 Applicable for SOHO solutions Manufactured acc. Link Performance Class E, for up to 250MHz, EN 50173 and ISO/IEC 11801 |
Original |
DN-91608SD 250MHz, S30400, LMSAD110 | |