Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    INTERPOSING CURRENT TRANSFORMER Search Results

    INTERPOSING CURRENT TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TCK111G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 1.1 to 5.5 V, 3.0 A, Inrush current reducing / Reverse current blocking, WCSP6C Datasheet
    TCK301G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK304G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK305G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK321G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C Datasheet

    Documents mentioning INTERPOSING CURRENT TRANSFORMER

    Document Partial File Text Tags Type PDF
    radsb
    Type RADSB A8EA 8R O W N BOVEFtf Transformer differential protection 1MDB04007-EN Page 1 March 1992 Changed since August 1990 Data subject to change wihtout notice ABB N etw ork Control & Protection (840536) I (90142) Features Application •Complete phase and earth fault protection
    OCR Scan PDF
    radsb
    Transformer differential protection RADSB 1MRK 504 002-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970883) Features • Three phase differential protection with two, three, five or six through-current restraint inputs
    Original PDF
    016-ben
    Multi-purpose percentage restraint differential protection RADSC 1MRK 509 016-BEN Page 1 Issued June 2002 Changed since June 1999 Data subject to change without notice (SE970169) Features • Complete phase and earth fault protection for generators, motors, reactors, cables or
    Original PDF
    RAYA Voltage regulating relay for tap changer
    RAYA Voltage regulating relay for tap changer control 1MRK 504 006-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE 84 05 42) Features • Accurate regulation of tap-changers • Inverse or definite time delay • Undervoltage and overcurrent blocking
    Original PDF
    1mdb04011-en
    Type RAYA Voltage regulating relay for tap changer control ASEA BROWN BGVEfii 1MDB04011-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection a i 1 , 0 á lú i- . ¿i M Irtfl ÌO í)O I¿ . a >
    OCR Scan PDF
    radss
    INFORMATION RFA, September 1981 Edition 1 From/Date Info-No. RF 637-333 E Reg. Page I Check zone for RADSS independent of switching in the current circuit The bus protection RADSS is normally equipped with an over­ current starting relay 5p. The starting relay S^ measures the
    OCR Scan PDF
    con
    Bulletin 500 Line Open Type Modular Kits and Components Selection Guide Bulletin 500, 500F, 509 NEMA AC Contactors and Starters Product Overview NEMA AC Contactor and Starter Modular Kits and Components NEMA sizes 0…4 for open-type Bulletin 500 top-wired contractors, Bulletin 500F feed-through contactors, and Bulletin 509 fullvoltage starters, are provided as modular kits for faster delivery. Other sizes and enclosed-type devices are also available.
    Original PDF
    rxma1
    Auxiliary, signalling and tripping relays RXMA1, RXMA 2, RXMM 1 RXMS 1, RXSF 1, RXME 1, RXME 18, RXMH 2 & RXMT 1 RXMM 1 (SE 90 06 16) RXSF 1 (SE 82 02 62) (SE 82 02 62) (SE 94 07 44) (SE 94 07 41) Page 1 Issued July 2007 Revision: B Data subject to change without notice
    Original PDF
    Bulletin 509 NEMA Full Voltage Starters Bulletin
    Bulletin 509 NEMA Full Voltage Starters Bulletin 509 D Broad Range of NEMA Sizes (00–9) D Exceptional Electrical Life D UL Certified Type 2 Coordination D Dependable Coil Operation D Cost Saving Design D SMP–1™ or SMP–3™ Solid-State Overload Relays
    Original PDF
    Across the line starters Open & enclosed
    Across the line starters Open & enclosed Description B9 – B75 • Maximum UL/CSA horsepower ratings • Compact space savings design • Standard auxiliary contact configurations: B9 - B25 1 N.O. or 1 N.C. B30 2 N.O. & 2 N.C. B40 - B75 1 N.O. & 1 N.C. • Additional auxiliary contact blocks are
    Original PDF
    aipm
    SNAP-AIPM Modules Features Description The SNAP-AIPM analog input modules provide an efficient way to monitor AC voltage and current using a SNAP PAC rack-mounted controller or SNAP PAC brain. These modules can be used with both standard wired SNAP PAC brains and controllers and
    Original PDF
    Gemstart 5 Volume 1 - Users Guide 276192-111 Rev.
    Gemstart 5 Volume 1 - Users Guide 276192-111 Rev. H Publication date: July 2014 Gemstart 5 Volume 1 – Users Guide Foreword This Technical Handbook provides the User with the information necessary to Install, Commission, Operate, Maintain and Test the equipment (as applicable). It is essential that
    Original PDF
    ret316
    Numerical transformer protection RET316*4 1MRK504007-Ben Page 1 Issued: February 2002 Changed since: December 1999 Data subject to change without notice Features • One three-phase differential function for two- or three-winding transformers • No interposing CTs
    Original PDF
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 & 
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 &  1MRK 504 018-BEN Page 1 Issued: March 2003 Revision: A Data subject to change without notice (SE960158) )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning • Easy to order
    Original PDF
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 & 
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 &  1MRK 504 020-BEN Page 1 Issued: March 2003 Revision: A Data subject to change without notice (SE960158) )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning • Easy to order
    Original PDF
    Accessories & Modification Codes 16-1 Accessories
    Accessories & Modification Codes 16-1 Accessories & Modification Codes April 2008 Contents 16 Description Page Accessories IT. NEMA… Freedom NEMA…
    Original PDF
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 & 
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 &  1MRK 504 040-BEN Page 1 Issued: March 2004 Revision: Data subject to change without notice (SE960158) )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning - Overexcitation restraint with 5th harmonic
    Original PDF
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 & 1MRK
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 & 1MRK 504 019-BEN Page 1 Issued March 2003 Revision: A Data subject to change without notice (SE960158) )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning • Easy to order
    Original PDF
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 & 
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 &  1MRK 504 042-BEN Page 1 Issued: March 2004 Revision: Data subject to change without notice (SE960158) )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning • Easy to order
    Original PDF
    APPLICATION NOTES flb BULLETIN 2100 CENTERLINE®
    APPLICATION NOTES flb BULLETIN 2100 CENTERLINE® MOTOR CONTROL CENTERS CONTROL CIRCUIT TRANSFORMER SELECTION Purpose Introduction The purpose of th is technical paper is to provide guidelines for th e proper selection of A llen-Bradley control circuit transform ers used in conjunction w ith the A llen-Bradley
    OCR Scan PDF
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 & 1MRK
    7UDQVIRUPHU SURWHFWLRQ WHUPLQDO 5(7 & 1MRK 504 041-BEN Page 1 Issued: March 2004 Revision: Data subject to change without notice (SE960158) )HDWXUHV • Pre-configured transformer terminal for cost-effective engineering and commissioning - Overexcitation restraint with 5th harmonic
    Original PDF
    PLEASE READ! This manual is intended to guide
    PLEASE READ! This manual is intended to guide qualified personnel in the installation and operation of this product. Because of the variety of uses for this equipment and because of the differences between this solid-state equipment and electromechanical equipment, the user of and those responsible
    Original PDF
    Opto 22 Energy Monitoring Unit Features
    Opto 22 Energy Monitoring Unit Features SNAP-IT-EMU1 Description The Opto 22 Energy Monitoring Unit (OptoEMU1) is a complete package of Opto 22 hardware and software that lets you monitor energy usage for a 3-phase electrical device—such as an air conditioning and heating unit, compressor, or electric motor—so
    Original PDF
    Electrical network protection Sepam series 20,
    Electrical network protection Sepam series 20, series 40, series 60, series 80 Digital protection relays Catalogue 2013 Sepam series 20 Sepam series 40 Sepam series 60 Sepam series 80 General Content Range description 1 Sepam series 20 and Sepam series 40
    Original PDF