Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    INTERFACE SIMA Search Results

    INTERFACE SIMA Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-VHDCIMX200-000.5
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-000.5 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male .5m PDF
    CS-VHDCIMX200-002
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-002 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 2m PDF
    CS-VHDCIMX200-003
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-003 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 3m PDF
    CS-VHDCIMX200-008
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-008 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 8m PDF
    CS-VHDCIMX200-005
    Amphenol Cables on Demand Amphenol CS-VHDCIMX200-005 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 5m PDF

    Documents mentioning INTERFACE SIMA

    Document Partial File Text Tags Type PDF
    Interface System passive interfaces passive
    Interface System passive interfaces passive interfaces Feldbuskoppler Interface modules Interface modules for S5 Interface modules make the connection between electronic and electrical components within the control panel. These interface modules have been
    Original PDF
    px 30
    Text Display S5-PG-Interface PX 30 PGS5 Technical Details Display Display type Number of lines Number of characters per line Height of character Dot matrix Character sets Message texts Compact text display with serial interface for connection to a Siemens SIMATIC S5.
    Original PDF
    mpc821
    SECTION 12 SYSTEM INTERFACE UNIT 12.1 INTRODUCTION The system interface unit (SIU) of the MPC821 consists of several functions that control system startup, initialization and operation, protection, and the external system bus. The following is a list of the system interface unit’s important features:
    Original PDF
    mpc860
    SECTION 12 SYSTEM INTERFACE UNIT 12.1 INTRODUCTION The system interface unit (SIU) of the MPC860 consists of several functions that control system startup, initialization and operation, protection, and the external system bus. The following is a list of the system interface unit’s important features:
    Original PDF
    simatic s5
    Text Display S5-PG-Interface PX 20 TTY-LC Technical Details Display Display type Number of lines Number of characters per line Height of character Dot matrix Character sets Message texts Compact text display with serial interface for connection to a Siemens SIMATIC S5.
    Original PDF
    siemens simatic s7
    Dupline® Plug & Play Master Module Interface for Siemens Simatic S7-200 PLC Type G 3496 0010 Du line ® Fieldbus Installationbus • Interface for Siemens Simatic S7-200 PLC with the function of a master • Plug and play: Automatic communication with specific
    Original PDF
    c1120
    C1120 S5 to II/O Lightbus Interface Beckhoff II/O-Lightbus System C1120 S5 to II/O-Lightbus Interface Technical Documentation VERSION 2.1 Date 27.06.97 Version 2.1 Page 1 of 52 C1120 S5 to II/O-Lightbus Interface Beckhoff II/O-Lightbus System Table of contents
    Original PDF
    Preface Contents SIMATIC NET CP 243-2
    Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Technical Description and Installation Instructions 1 Interface to the User Program in the S7-200 CPU 2 Access to the Data of the AS-i Slaves 3 Signaling Errors and Diagnostics in the User Program 4
    Original PDF
    ht95r5x
    Using the I2C Interface in the HT95R5x/HT95R6x Using the I2C Interface in the HT95R5x/HT95R6x D/N:HA0217E Introduction The HT95R5x/HT95R6x provides a SIM serial data transfer function, which includes both 2 2 SPI and I C interface types. The following application uses the HT95R5x/HT95R6x I C
    Original PDF
    c1120
    C1120 S5 zu II/O Interface Baugruppe Beckhoff II/OII/O-System C1120 S5 zu II/O Interface Baugruppe Technische Beschreibung VERSION 2.20 Eiserstraße 5 D-33415 Verl Telefon 05246/963-0 Telefax 05246/963-149 Version 2.20 Seite 1 von 78 C1120 S5 zu II/O Interface Ba
    Original PDF
    simatic s5
    IBS S5 100 SL-T Data Sheet INTERBUS Slave Remote Interface for SIMATIC S5 90U, S5 95U and S5 100U Data Sheet Revision B 01/1997 Product Description You can use the IBS S5 100 SL-T slave remote interface to connect SIMATIC S5 90U, 95U and 100U PLCs to a higher-level PLC system via
    Original PDF
    mpc860
    MPC860 Overview Memory Map Hardware Interface Overview PowerPC Core Overview PowerPC Core Register Set MPC860 Instruction Set PowerPC Exceptions Instruction and Data Caches Memory Management Unit Instruction Execution Timing System Interface Unit Reset External Signals
    Original PDF
    mpc555
    SECTION 5 UNIFIED SYSTEM INTERFACE UNIT The unified system interface unit (USIU) of the MPC555 / MPC556 controls system start-up, system initialization and operation, system protection, and the external system bus. The MPC555 / MPC556 USIU functions include the following:
    Original PDF
    mpc555
    SECTION 5 UNIFIED SYSTEM INTERFACE UNIT The unified system interface unit (USIU) of the MPC555 / MPC556 controls system start-up, system initialization and operation, system protection, and the external system bus. The MPC555 / MPC556 USIU functions include the following:
    Original PDF
    pxt 5 pgs5
    Operator Terminal S5-PG-Interface PXT 5 PGS5 Technical Details Display Display type Number of lines Number of characters per line Height of character Dot matrix Character sets Message texts Compact operator terminal with serial interface for connection to a
    Original PDF
    Text Display Serial Combi-Interface PX 20 COM-LC
    Text Display Serial Combi-Interface PX 20 COM-LC Technical Details Display Display type Number of lines Number of characters per line Height of character Dot matrix Character sets Message texts Compact text display with serial combi-interface which permits
    Original PDF
    mpc555
    SECTION 5 UNIFIED SYSTEM INTERFACE UNIT The unified system interface unit (USIU) of the MPC555 controls system start-up, system initialization and operation, system protection, and the external system bus. The MPC555 USIU functions include the following: • System configuration and protection
    Original PDF
    mpc555
    SECTION 5 UNIFIED SYSTEM INTERFACE UNIT The unified system interface unit (USIU) of the MPC555 controls system start-up, system initialization and operation, system protection, and the external system bus. The MPC555 USIU functions include the following: • System configuration and protection
    Original PDF
    PLC System Interface 32 PLC System Interface
    PLC System Interface 32 PLC System Interface Single wiring System cabling As a rule, commercially available PLC I/O cards have two different connection technologies available: - Screw connection technology Until now, high installation and commissioning costs have been generated - Crimp connection technology
    Original PDF
    Operator Terminal Serial Combi-Interface PXT 305
    Operator Terminal Serial Combi-Interface PXT 305 COM-LC/PXT 305 COM-LC KYR Technical Details Display Display type Number of lines Number of characters per line Height of character Dot matrix Character sets Message texts Compact operator terminal with serial combi-interface which permits
    Original PDF
    mpc561
    SECTION 5 UNIFIED SYSTEM INTERFACE UNIT (USIU) The unified system interface unit (USIU) of the MPC561 / MPC563 consists of several functional modules that control system start-up, system initialization and operation, system protection, and the external system bus. The MPC561 / MPC563 USIU functions include the following:
    Original PDF
    mpc565
    SECTION 5 UNIFIED SYSTEM INTERFACE UNIT (USIU) 5.1 USIU Introduction The unified system interface unit (USIU) of the MPC565 / MPC566 consists of several functional modules that control system start-up, system initialization and operation, system protection, and the external system bus. The MPC565 / MPC566 USIU functions include the following:
    Original PDF