INRUSH RE Search Results
INRUSH RE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCK111G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 1.1 to 5.5 V, 3.0 A, Inrush current reducing / Reverse current blocking, WCSP6C | Datasheet | ||
| TCK301G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK304G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK305G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK321G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C | Datasheet |
Documents mentioning INRUSH RE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| advertisement ThinSOT Switching Regulator | advertisement ThinSOT Switching Regulator Controls Inrush Current Design Note 365 Jesus Rosales Introduction Inrush current can be troublesome, especially when regulators are operated from batteries or a current-limited source. In such cases, excessive inrush current can cause |
Original | ||||
| Damping of Inrush Current in Low-Voltage PFC | Damping of Inrush Current in Low-Voltage PFC Equipment Low-Voltage PFC Application Note 2001 http://www.epcos.com Power Quality Contents 2 General 3 The risks of high inrush current 4 Single capacitor connection, inrush current calculation 6 Parallel capacitor connection, inrush current calculation |
Original | ||||
| POWER THERMISTOR FOR THE REDUCTION OF INRUSH | POWER THERMISTOR FOR THE REDUCTION OF INRUSH CURRENT A power thermistor is a type of NTC thermistor used for the reduction of large inrush currents. These large inrush currents are typically caused by charging of filter capacitors in switching power supplies. |
Original | ||||
| tokin | DATA SHEET EC2/EE2 SERIES High-inrush capability type RoHS Compliant COMPACT SIZE, SLIM-PACKAGE DESCRIPTION NEC TOKIN EC2/EE2 relay is a standard miniature signal relay, compact and slim. High-inrush capability type can endure 10A inrush for 24Vdc. FEATURES |
Original | ||||
| dvcl | DVCL28 Series HIGH RELIABILITY HYBRID INRUSH CURRENT LIMITER DESCRIPTION FEATURES The DVCL28 Inrush Current Limiter is operable over the full military (-55 °C to +125 °C) temperature range with no power derating. The DVCL28 is designed to control the inrush current drawn by |
Original | ||||
| dvcl28 | DVCL28 Series HIGH RELIABILITY HYBRID INRUSH CURRENT LIMITER DESCRIPTION FEATURES The DVCL28 Inrush Current Limiter is operable over the full military (-55 °C to +125 °C) temperature range with no power derating. The DVCL28 is designed to control the inrush current drawn by |
Original | ||||
| g POWER THERMISTOR FOR THE REDUCTION OF INRUSH | g POWER THERMISTOR FOR THE REDUCTION OF INRUSH CURRENT A power thermistor is a type of NTC thermistor used for the reduction of large inrush currents. These large inrush currents are typically caused by charging of filter capacitors in switching power supplies. |
Original | ||||
| Partly Order Discontinued as of August 31, 2011 | Partly Order Discontinued as of August 31, 2011 VDE Wide variation 1a 15A, 2a 10A power relays PC board type Plug-in type JC RELAYS FEATURES TYPICAL APPLICATIONS • High inrush current capability 1 Form A: 163 A inrush (TV-8) 2 Form A: 111 A inrush (TV-5) |
Original | ||||
| Special Load PCB Relay 409 47, 409 67 1 pole 10 | Special Load PCB Relay 409 47, 409 67 1 pole 10 A, for high inrush currents, mono- or bistable Features • Specifically designed to handle high inrush currents Tungsten prerun contact 500 A / 10 ms inrush peak current 4 kV / 8 mm coil-contact |
Original | ||||
| ntc thermistors | Thermistors, RTDs, Probes & Assemblies 1-800-777-6467 Inrush Current Limiting Power NTC Thermistors U.S. Sensor’s inrush current limiting power thermistors are specially formulated and processed NTC thermistors suitable for suppressing high inrush currents in switching |
Original | ||||
| VDE Wide variation 1a 15A, 2a 10A power relays PC | VDE Wide variation 1a 15A, 2a 10A power relays PC board type Plug-in type JC RELAYS FEATURES TYPICAL APPLICATIONS • High inrush current capability 1 Form A: 163 A inrush (TV-8) 2 Form A: 111 A inrush (TV-5) • High dielectric withstanding for transient protection: |
Original | ||||
| lr26550 | JC COMPACT POWER RELAYS JC-RELAYS UL File No.: E43028 CSA File No.: LR26550 19.0 .748 30.4 1.197 mm inch • High inrush current capability 1 Form A: 163 A inrush (TV-8) 2 Form A: 111 A inrush (TV-5) • High dielectric withstanding for transient protection: |
Original | ||||
| VDE Wide variation 1a 15A, 2a 10A power relays PC | VDE Wide variation 1a 15A, 2a 10A power relays PC board type Plug-in type JC RELAYS FEATURES TYPICAL APPLICATIONS • High inrush current capability 1 Form A: 163 A inrush (TV-8) 2 Form A: 111 A inrush (TV-5) • High dielectric withstanding for transient protection: |
Original | ||||
| VDE COMPACT POWER RELAYS JC-RELAYS FEATURES 30.0 | VDE COMPACT POWER RELAYS JC-RELAYS FEATURES 30.0 1.181 19.0 .748 • High inrush current capability 1 Form A: 163 A inrush (TV-8) 2 Form A: 111 A inrush (TV-5) • High dielectric withstanding for transient protection: JC can withstand 10,000 V surge in µs between coil and contact. |
Original | ||||
|
|
||||||
| VDE COMPACT POWER RELAYS JC-RELAYS FEATURES 30.0 | VDE COMPACT POWER RELAYS JC-RELAYS FEATURES 30.0 1.181 19.0 .748 • High inrush current capability 1 Form A: 163 A inrush (TV-8) 2 Form A: 111 A inrush (TV-5) • High dielectric withstanding for transient protection: JC can withstand 10,000 V surge in µs between coil and contact. |
Original | ||||
| Inrush Current Limiting Power Thermistors U.S. | Inrush Current Limiting Power Thermistors U.S. Sensor’s inrush current limiting power thermistors are specially formulated and processed NTC thermistors suitable for suppressing high inrush currents in switching power supplies and other applications where the high initial starting currents are |
Original | ||||
| jc relay | JC Discontinued as of August 31, 2011 Discontinued as of August 31, 2011 Wide variation 1a 15A, 2a 10A power relays PC board type Plug-in type JC RELAYS FEATURES TYPICAL APPLICATIONS • High inrush current capability 1 Form A: 163 A inrush (TV-8) 2 Form A: 111 A inrush (TV-5) |
Original | ||||
| ntc thermistors for inrush current limiting | NTC thermistors for inrush current limiting Summary APPLICATIONS: NTC thermistors for inrush current limiting, as all NTCs, are made of polycrystalline mixed oxide ceramics. They suppress high inrush current surges, which occur when, for example, low impedance smoothing capacitors |
Original | ||||
| thermistors | Inrush Current Limiting Power Thermistors U.S. Sensor’s inrush current limiting power thermistors are specially formulated and processed NTC thermistors suitable for suppressing high inrush currents in switching power supplies and other applications where the high initial starting currents are |
Original | ||||
| ntc thermistors for inrush current limiting | Application Note NTC Thermistors for Inrush Current Limiting www.epcos.com Notes Application Note NTC thermistors for inrush current limiting Content 1. Summary… 3 |
Original | ||||
| lr26550 | JC COMPACT POWER RELAYS 19.0 .748 30.4 1.197 mm inch UL File No.: E43028, CSA File No.: LR26550 VDE File No.: VDE-REG.-Nr. 894, SEMKO, SEV • High inrush current capability 1 Form A: 163 A inrush (TV-8) 2 Form A: 111 A inrush (TV-5) • High dielectric withstanding for transient protection: |
Original | ||||