IMMERSION TEMPERATURE SE Search Results
IMMERSION TEMPERATURE SE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| CO-316SMAX200-001 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-001 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 1ft | |||
| CO-316SMAX200-003 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-003 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 3ft | |||
| CO-316SMAX200-004 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-004 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 4ft | |||
| CO-316SMAX200-010 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-010 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 10ft | |||
| CO-316SMAX200-005 | Amphenol Cables on Demand | Amphenol CO-316SMAX200-005 RG316 High Temperature Teflon Coaxial Cable - SMA Male to SMA Male 5ft |
Documents mentioning IMMERSION TEMPERATURE SE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ft-t1k1 | 1 Immersion temperature sensor 796 FT-T1K1 for hydraulic systems Immersion sensor for the measurement of water temperatures in hydraulic systems. • T1 sensing element • Fast response • Installed with immersion pocket Application The FT-T1K1 immersion temperature sensor is used primarily in HVAC hydraulic |
Original | ||||
| 1791p01 | 1 791 1791P01… Immersion temperature sensors QAE22… Immersion sensor for acquiring the water temperature in pipes or tanks. Use Acquisition of the water temperature for • controlling or limiting the flow temperature • limiting the return temperature |
Original | ||||
| immersion | 1 Immersion sensor 795 FTRL-T1 Immersion sensor for heating, ventilation and air conditioning systems. • T1 measuring element T1 • Fast response time • Cylindrical stainless immersion pocket • Immersion pocket length 420 mm Use The FTRL-T1 immersion temperature sensor is mainly used in hydraulic circuits in |
Original | ||||
| pt100 sensor | 1 797 FT-TP/100 FT-TP/400 Immersion temperature sensor for HVAC systems Immersion temperature sensor for heating, ventilation and air conditioning systems • For use with controllers with Pt100 sensor inputs • In conjunction with MULTIREG and INTEGRAL RS. |
Original | ||||
| ft-t1q | 1 Immersion temperature sensor 793 FT-T1Q… for fast-response measurement in hydraulic systems Immersion temperature sensors for fast-response measurements • T1 measuring element • Suitable for domestic water and other liquid media • For use in very fast-response controlled systems |
Original | ||||
| aciswd | ACISWD2 Series Page 4 Qualification and Reliability Tests Type of Test Damp heat High temperature storage Low temperature storage Temperature cycling Temperature humidity cycling Water immersion Vibration Impact Cable retention Conditions 85 °C and 85% RH |
Original | ||||
| RTDs: TYPE JTRC RTD IN THREADED STAINLESS STEEL | RTDs: TYPE JTRC RTD IN THREADED STAINLESS STEEL BODY DESCRIPTION: Stainless steel threaded body with connector. integral FEATURES: • Robust • Compact • Suitable for all applications with low temperature, short immersion and fast response times • Screw-in RTD probe for direct immersion, one |
Original | ||||
| g RTDs: TYPE JTRC RTD IN THREADED STAINLESS STEEL | g RTDs: TYPE JTRC RTD IN THREADED STAINLESS STEEL BODY DESCRIPTION: Stainless steel threaded body with connector. integral FEATURES: • Robust • Compact • Suitable for all applications with low temperature, short immersion and fast response times • Screw-in RTD probe for direct immersion, one |
Original | ||||
| qaz21 | 1 1833P014 848 Cable Temperature Sensors QAZ21.682/101 QAZ21.685/101 for use in refrigeration plant Cable temperature sensor for acquiring the medium temperature in refrigeration plant. Strap-on sensor with 2 cable ties or immersion sensor with a protection |
Original | ||||
| CCMS Series Common Mode Inductors In Square | CCMS Series Common Mode Inductors In Square Package, Commercial Applications FEATURES Operating Temperature Range: -55 ºC to +125 ºC Temperature Rise @ rated current: < 30 ºC Dielectric Withstanding Voltage: 500 Vac Moisture, Shock and Immersion Resistant |
Original | ||||
| qae26 | 1 1790P01 790 Immersion Temperature Sensors QAE26.9… Use Acquisition of flow or return temperature in heating, ventilating, and air conditioning plants. Type summary Type Measuring range Cable length Time constant Mounting length Nominal pressure QAE26.9 |
Original | ||||
| CMS Series Common Mode Inductors In Square | CMS Series Common Mode Inductors In Square Package FEATURES Operating Temperature Range: -55 ºC to +125 ºC Temperature Rise @ rated current: < 30 ºC Dielectric Withstanding Voltage: 500 Vac Moisture, Shock and Immersion Resistant Resistance to Soldering Heat: 265 ºC for 10 secs |
Original | ||||
| pc565 | PC565 Ultraminiature Automotive PCB Power Relay FEATURES Ultraminiature design very light weight Sensitive Coil (low pull in voltage) available Contact switching capacity up to 30 Amps Sealed, immersion cleanable Up to105 degrees C operating temperature CONTACT RATINGS |
Original | ||||
| betatherm | BetaTHERM Sensors Custom and Standard HVAC Probes Style: H475 Spherical Ended Nickel Plated Brass Probe: Applications: ¥ General purpose HVAC probe. ¥ Refrigeration Cabinets. ¥ Immersion probe for use in liquids. ¥ Agricultural temperature monitoring. |
Original | ||||
|
|
||||||
| 1794p01 | 1 1794P01 794 QAE3010… QAE3075… Immersion Temperature Sensors Use The sensors are used for acquiring the temperature of liquid or gaseous media (e.g. heating water) in heating, ventilation or air conditioning plants. They are designed for use in connection with automation equipment, display and logging devices. |
Original | ||||
| ® Non-Contacting Position Sensors Typical | ® Non-Contacting Position Sensors Typical Applications : Throttle & Pedal Position Features / Benefits: • Temperature Stable • 10-12 Bit Resolution • Recommend for High Thermal Shock, Water Spray/Immersion and Vibration Applications • |
Original | ||||
| qae100b | 1 799 With connecting head type B made of aluminium With connecting head made of plastic Immersion temperature sensors QAE100B… QAE160B… QAE170B… Use The sensors are used for acquiring the temperature of liquid or gaseous media (e.g. heating water) in heating, ventilation or air conditioning plants. |
Original | ||||