IIC ISOLATOR Search Results
IIC ISOLATOR Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
MYC0409-NA-EVM | Murata Manufacturing Co Ltd | 72W, Charge Pump Module, non-isolated DC/DC Converter, Evaluation board | |||
DCL540D01 |
![]() |
Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: High | Datasheet | ||
DCL540C01 |
![]() |
Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: Low | Datasheet | ||
DCL540H01 |
![]() |
Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=4:0) / Default Output Logic: High / Output enable | Datasheet | ||
DCL541L01 |
![]() |
Digital Isolator / VDD=2.25~5.5V / 150Mbps / 4 channel(F:R=3:1) / Default Output Logic: Low / Output enable | Datasheet |
IIC ISOLATOR Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
OPI110
Abstract: OPI-110 OPI110D
|
Original |
OPI-110 95C2096U OPI-110, EN50020 EN50014 01ATEX1278U 94/9/EC OPI110 OPI110D | |
OPI110
Abstract: OPI-110 10KV DIODE EN50014 01ATEX1278U OPI110B
|
Original |
OPI-110 95C2096U OPI-110, EN50020 EN50014 01ATEX1278U 94/9/EC OPI110 10KV DIODE 01ATEX1278U OPI110B | |
Contextual Info: I.S. Relay Module Series 9172 A3 > For binary signal and control circuits > Intrinsically safe inputs or outputs [Ex ia] IIC A3 > Galvanic isolation between inputs and outputs > For use up to SIL 2 IEC 61508 A3 A3 www.stahl.de A3 A3 Series 9172 A3 08578E00 |
Original |
08578E00 interfac00s 9172/21-11-00s 9172/22-11-00s 09685E00 | |
ABB katharometer 6539960
Abstract: BAS 98 ATEX 6539960 AK104 BAS 01 ATEX 1042 ATEX 7041 zener barrier AK102 ABB pressure regulator Hydrogen purity
|
Original |
SS/AK100 AK100 AK101 AK102 AK102 ABB katharometer 6539960 BAS 98 ATEX 6539960 AK104 BAS 01 ATEX 1042 ATEX 7041 zener barrier ABB pressure regulator Hydrogen purity | |
MTL5549
Abstract: MTL5549Y TAG 281 800 MTL5500 Hand-Held Communicator 24V 4.....20MA TH500 TH5000
|
Original |
EPS5549/49Y-3 MTL5549/5549Y 4/20mA 500Hz 10kHz MTL5549 MTL5549Y TAG 281 800 MTL5500 Hand-Held Communicator 24V 4.....20MA TH500 TH5000 | |
dc 8069
Abstract: intrinsically safe METAL DETECTOR circuit for make MTL5521 hart hazardous area EPS5521-2
|
Original |
EPS5521-2 MTL5521 35Vdc dc 8069 intrinsically safe METAL DETECTOR circuit for make hart hazardous area EPS5521-2 | |
Contextual Info: Analog signal isolator 1-channel IM35-11EX-HI The standard current signal is galvanically separated and transferred via the 1-channel isolating transducer IM35-11EX-HI from the non-Ex area to the Ex-area without attenuation 1:1 . In addition to analog signals, |
Original |
IM35-11EX-HI IM35-11EX-HI D-45472 2013-07-13T20 | |
Contextual Info: Analog signal isolator 2-channel IM35-22EX-HI The standard current signal is galvanically separated and transferred via the 2-channel isolating transducer IM35-22EX-HI from the non-Ex area to the Ex-area without attenuation 1:1 . In addition to analog signals, |
Original |
IM35-22EX-HI IM35-22EX-HI D-45472 2013-07-13T20 | |
250 A Knife Switch
Abstract: ATEX1160
|
Original |
ATEX1160 D2239 250 A Knife Switch ATEX1160 | |
Contextual Info: Analog signal isolator 1-channel IMC-AO-11EX-I/L The 1-channel analog signal isolator IMCAO-11Ex-i/L features an intrinsically safe input circuit. The device can be mounted in zone 2. Intrinsically analog actuators like I/P converters e.g. at control valves or displays can be |
Original |
IMC-AO-11EX-I/L IMCAO-11Ex-i/L 2013-07-13T20 D-45472 | |
02 atex 1090Contextual Info: Analog signal isolator 1-channel IME-AO-11Ex-Hi/L The analogue data transmitter IME-AO-11Ex-i/ L features 1 channel and the input circuit is intrinsically safe. The device is loop-powered. • ■ Intrinsically safe output circuit Ex ia Application area acc. to ATEX: II 1 G, II |
Original |
IME-AO-11Ex-Hi/L IME-AO-11Ex-i/ 2013-07-13T20 D-45472 02 atex 1090 | |
Contextual Info: Analog signal isolator 2-channel IM35-22EX-HI/24VDC The standard current signal is galvanically separated and transferred via the 2-channel isolating transducer IM35-22EX-HI/24VDC from the non-Ex area to the Ex-area without attenuation 1:1 . In addition to analog signals, |
Original |
IM35-22EX-HI/24VDC D-45472 2013-07-13T20 | |
Contextual Info: Analog signal isolator 1-channel IM31-12EX-I Standard active voltage or current signals are galvanically separated and transferred via the 1-channel analog signal isolator IM31-12EX-I from the Ex area to the non-Ex area. The signal is duplicated and provided at both outputs. |
Original |
IM31-12EX-I 2013-07-13T20 D-45472 | |
Contextual Info: Analog signal isolator 1-channel IM31-11EX-U The single-channel analog data transmitter IM31-11Ex-U transmits standard active voltage or current signals. The device is equipped with one input circuit of 0/2…10 V or 0/4…20 mA and one short-circuit proof output circuit of 0/2…10 V. |
Original |
IM31-11EX-U IM31-11Ex-U 2013-07-13T20 D-45472 | |
|
|||
Contextual Info: Analog signal isolator 1-channel IM31-11EX-I Active voltage or current signals are galvanically isolated and transmitted via the 1-channel analog data transmitter IM31-11EX-I from the Ex area to the safe area. The device is equipped with one input circuit |
Original |
IM31-11EX-I IM31-11EX-I 2013-07-13T20 D-45472 | |
Contextual Info: Analog signal isolator 2-channel IM31-22EX-I Isolated active voltage or current signals are galvanically isolated and transmitted via the 2channel analog data transmitter IM31-22EX-I from the Ex area to the safe area. The device features two input circuits of 0/2… |
Original |
IM31-22EX-I 2013-07-13T20 D-45472 | |
Contextual Info: Analog signal isolator 2-channel IM31-22EX-U Galvanically isolated active voltage or current signals are transmitted via the 2-channel analog data transmitter IM31-22EX-U from the Ex area to the safe area. The device features two input circuits of 0/2… 10 V and 0/4…20 mA as well as two short-circuit proof output circuits of 0…10 V. |
Original |
IM31-22EX-U IM31-22EX-U 2013-07-13T20 D-45472 | |
namur NE 93
Abstract: EN50082-2
|
Original |
||
HART Communication Compliance
Abstract: EN50082-2 namur NE 93 digital Isolator interface
|
Original |
||
EN50082-2Contextual Info: Output Isolator Without HART for 0/4.20 mA Signals PI/Ex-ME-ID-I/I 1. Modular Electronic Interface for Process Technology Process systems are characterized by a large number of signals. A large proportion of these signals are Ex-i signals, which are not always routed. In this |
Original |
||
Contextual Info: Analog signal isolator 2-channel IMB-AO-22Ex-Hi/24VDC The 2-channel HART output isolator IMB-AO-22Ex-Hi/24VDC is designed to galvanically separate and transfer standard current signals from the non-Ex to the Ex-area without attenuation 1:1 . In addition to analog signals, the isolating transducer also transfers digital |
Original |
IMB-AO-22Ex-Hi/24VDC IMB-AO-22Ex-Hi/24VDC 2013-07-13T20 D-45472 | |
Contextual Info: Analog signal isolator 1-channel IME-Ai-11Ex-Hi/L Active current signals are galvanically isolated and transmitted via the 1-port analog data transmitter IME-Ai-11EX-i/L from the Ex area to the safe area. The device features one input circuit 0/4…20 mA and one short-circuit proof output circuit |
Original |
IME-Ai-11Ex-Hi/L IME-Ai-11EX-i/L 2013-07-13T20 D-45472 | |
Contextual Info: Analog signal isolator 1-channel IME-AI-11Ex-Hi/24VDC Active current signals are galvanically isolated and transmitted via the single-channel analog signal isolator IME-AI-11EX-Hi/24VDC from the Ex area to the safe area. Bidirectional transmission of analog and digital HART communication signals. |
Original |
IME-AI-11Ex-Hi/24VDC IME-AI-11EX-Hi/24VDC 10ATEX555276X 2013-07-13T20 D-45472 | |
Catalog Sensors for Process Applications
Abstract: NCB1.5-8GM25-N0 5M
|
Original |
199003130E Catalog Sensors for Process Applications NCB1.5-8GM25-N0 5M |